Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography

被引:66
|
作者
Malle, Caroline [1 ,2 ]
Tada, Tomohisa [1 ,2 ]
Steigerwald, Kristin [1 ,2 ]
Ughi, Giovanni J. [3 ,4 ]
Schuster, Tibor [1 ,2 ]
Nakano, Masataka [7 ]
Massberg, Steffen [1 ,2 ]
Jehle, Johannes [1 ,2 ,5 ]
Guagliumi, Giulio [6 ]
Kastrati, Adnan [1 ,2 ]
Virmani, Renu [7 ]
Byrne, Robert A. [1 ,2 ]
Joner, Michael [1 ,2 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Deutsch Herzzentrum, D-80290 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-80290 Munich, Germany
[3] Katholieke Univ Leuven, Dept Cardiovasc Dis, Louvain, Belgium
[4] Katholieke Univ Leuven, Dept Cardiovasc Sci, Louvain, Belgium
[5] Univ Furstentum Liechtenstein, Triesen, Liechtenstein
[6] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24100 Bergamo, Italy
[7] CVPath Inst Inc, Gaithersburg, MD USA
关键词
atherosclerosis; drug-eluting stents; gray-scale; optical coherence tomography; signal intensity; vascular healing; MORPHOLOGICAL PREDICTORS; HUMANS; RESTENOSIS; THROMBOSIS; PATHOLOGY; COVERAGE;
D O I
10.1161/ATVBAHA.113.301227
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To validate optical coherence tomography (OCT) imaging for assessment of vascular healing in a preclinical animal model and human autopsy cases and to translate the findings to the assessment of vascular healing after drugeluting stent implantation in clinical practice. Approach and Results-Drug-eluting and bare metal stents were imaged 28 and 42 days after implantation in atherosclerotic rabbits using OCT and simultaneously evaluated by histology. After coregistration with histology, gray-scale signal intensity (GSI) was measured for identified mature or immature neointimal tissue. Autopsy specimens were imaged with OCT and GSI values correlated with histology. Finally, prospective OCT imaging and GSI measurements were acquired in 10 patients undergoing follow-up 6 months after stenting with drug-eluting stents. Histopathologic and OCT morphometric analysis of implanted stents showed excellent correlation. Neointimal growth and vessel healing at 28 days in the animal model best correlated with human stented arteries at 6 months. In animal and human autopsy specimens, mature neointimal tissue consistently showed higher GSI values. Receiver operating characteristic curve analysis displayed high sensitivity and specificity for detection of mature neointima in animal (96% and 79%, respectively) and human autopsy (89% and 71%, respectively) data. In patients undergoing OCT follow-up 6 months after drug-eluting stent implantation, prospective GSI analysis revealed that a minimum of 27.7% of areas above stent struts represented mature neointima. Conclusions-Novel GSI analysis of OCT imaging data allows distinction between mature and immature neointimal tissue in animal models, autopsy specimens, and patients undergoing invasive surveillance in simple atherosclerotic lesions.
引用
收藏
页码:1376 / +
页数:18
相关论文
共 50 条
  • [21] Neointimal tissue characterization after implantation of drug-eluting stents by optical coherence tomography: quantitative analysis of optical density
    Nishino, Setsu
    Sakuma, Masashi
    Kanaya, Tomoaki
    Nasuno, Takahisa
    Tokura, Michiaki
    Toyoda, Shigeru
    Abe, Shichiro
    Nakamura, Daisuke
    Tanaka, Kentaro
    Attizzani, Guiherme F.
    Bezerra, Hiram G.
    Costa, Marco A.
    Inoue, Teruo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (11): : 1971 - 1978
  • [22] THE MORPHOLOGICAL FINDINGS OF IN-STENT RESTENOTIC TISSUE AFTER FIRST GENERATION DRUG-ELUTING STENT IMPLANTATION: OPTICAL COHERENCE TOMOGRAPHY STUDY
    Habara, Maoto
    Terashima, Mitsuyasu
    Nasu, Kenya
    Ko, Euihong
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Suzuki, Takahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E124 - E124
  • [23] Comparison of Neoatherosclerosis and Neovascularization of Restenosis after Drug-Eluting Stent Implantation: An Optical Coherence Tomography Study
    Deng, Chancui
    Liu, Zhijiang
    Zhang, Wei
    Deng, Yi
    Liu, Hanlin
    Bai, Zhixun
    Rong, Jidong
    Deng, Wenwen
    Gu, Ning
    Shen, Youcheng
    Hu, Xingwei
    Zhao, Yongchao
    Zhao, Ranzun
    Shi, Bei
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (12)
  • [24] Optical coherence tomography assessment of edge dissections after drug-eluting stent implantation in coronary artery
    GUO JunCHEN YundaiTIAN FengLIU HongbinCHEN LianSUN ZhijunREN YihongJIN Qinhua LIU ChangfuHAN BaoshiGAI Luyue and YANG Tingshu Department of CardiologyChinese Peoples Liberation Army General HospitalBeijing China
    中华医学杂志(英文版), 2012, (06) : 1047 - 1050
  • [25] Microbubble contrast enhancement of neointima after drug-eluting stent implantation: an optical coherence tomography study
    Norikiyo Oka
    Tadayuki Kadohira
    Kenichi Fujii
    Hideki Kitahara
    Yoshihide Fujimoto
    Yoshio Kobayashi
    Heart and Vessels, 2019, 34 : 393 - 400
  • [26] Microbubble contrast enhancement of neointima after drug-eluting stent implantation: an optical coherence tomography study
    Oka, Norikiyo
    Kadohira, Tadayuki
    Fujii, Kenichi
    Kitahara, Hideki
    Fujimoto, Yoshihide
    Kobayashi, Yoshio
    HEART AND VESSELS, 2019, 34 (03) : 393 - 400
  • [27] Optical coherence tomography assessment of edge dissections after drug-eluting stent implantation in coronary artery
    Guo Jun
    Chen Yun-dai
    Tian Feng
    Liu Hong-bin
    Chen Lian
    Sun Zhi-jun
    Ren Yi-hong
    Jin Qin-hua
    Liu Chang-fu
    Han Bao-shi
    Gai Lu-yue
    Yang Ting-shu
    CHINESE MEDICAL JOURNAL, 2012, 125 (06) : 1047 - 1050
  • [28] CLOPIDOGREL RESISTANCE AND INTRA-STENT THROMBI ASSESSED BY OPTICAL COHERENCE TOMOGRAPHY AFTER DRUG-ELUTING STENT IMPLANTATION
    Fukuhara, Kenzo
    Okura, Hiroyuki
    Koyama, Terumasa
    Yamada, Ryotaro
    Kume, Teruyoshi
    Hayashida, Akihiro
    Neishi, Yoji
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1607 - A1607
  • [29] PROGNOSTIC FACTORS FOR STENT FAILURE AFTER DRUG-ELUTING STENT IMPLANTATION FOR CALCIFIED NODULES: AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Hamana, Tomoyo
    Otake, Hiromasa
    Nishimori, Makoto
    Kawamori, Hiroyuki
    Toba, Takayoshi
    Hirata, Ken-Ichi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 791 - 791
  • [30] Optical Coherence Tomographic Observation of Morphological Features of Neointimal Tissue after Drug-Eluting Stent Implantation
    Lee, Seung-Yul
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    YONSEI MEDICAL JOURNAL, 2014, 55 (04) : 944 - 952