CLINICAL FACTORS AFFECTING THE ACCURACY OF GUIDED IMPLANT SURGERY-A SYSTEMATIC REVIEW AND META-ANALYSIS

被引:145
|
作者
Zhou, Wenjuan [1 ,2 ,3 ]
Liu, Zhonghao [1 ]
Song, Liansheng [2 ]
Kuo, Chia-Ling [4 ]
Shafer, David M. [2 ]
机构
[1] Binzhou Med Univ, Yantai Stomatol Hosp, Dept Implant Dent, Yantai, Peoples R China
[2] UConn Sch Dent Med, Div Oral & Maxillofacial Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[3] Med Univ Vienna, Univ Clin Dent, Competent Ctr Periodontal Res, Div Conservat Dent & Periodontol, Vienna, Austria
[4] UConn Hlth, CT Inst Clin & Translat Sci, Farmington, CT USA
关键词
Dental implants; Computer-assisted; Guided surgery; Surgical guides; Accuracy; CONE-BEAM CT; STEREOLITHOGRAPHIC SURGICAL TEMPLATES; COMPUTED-TOMOGRAPHY; DENTAL IMPLANTS; PLACEMENT; COMPLICATIONS; RELIABILITY; NAVIGATION; POSITIONS; DEVIATION;
D O I
10.1016/j.jebdp.2017.07.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To systematically review the current dental literature regarding clinical accuracy of guided implant surgery and to analyze the involved clinical factors. Material and Methods PubMed and Cochrane Central Register of Controlled Trials were searched. Meta-analysis and meta-regression analysis were performed. Clinical studies with the following outcome measurements were included: (1) angle deviation, (2) deviation at the entry point, and (3) deviation at the apex. The involved clinical factors were further evaluated. Results Fourteen clinical studies from 1951 articles initially identified met the inclusion criteria. Meta-regression analysis revealed a mean deviation at the entry point of 1.25 mm (95% confidence interval [CI]: 1.22-1.29), 1.57 mm (95% CI: 1.53-1.62) at the apex, and 4.1 degrees in angle (95% CI: 3.97-4.23). A statistically significant difference (P<.001) was observed in angular deviations between the maxilla and mandible. Partially guided surgery showed a statistically significant greater deviation in angle (P<. 001), at the entry point (P<. 001), and at the apex (P<. 001) compared with totally guided surgery. The outcome of guided surgery with flapless approach indicated significantly more accuracy in angle (P<. 001), at the entry point (P<.001), and at apex (P<.001). Significant differences were observed in angular deviation based on the use of fixation screw (P<. 001). Conclusions The position of guide, guide fixation, type of guide, and flap approach could influence the accuracy of computer-aided implant surgery. A totally guided system using fixation screws with a flapless protocol demonstrated the greatest accuracy. Future clinical research should use a standardized measurement technique for improved accuracy.
引用
收藏
页码:28 / 40
页数:13
相关论文
共 50 条
  • [41] Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Knipper, Anne
    Luthardt, Ralph G.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) : 1 - 20
  • [42] Role of Dynamic Navigation Systems in Enhancing the Accuracy of Implant Placement: A Systematic Review and Meta-Analysis of Clinical Studies
    Wang, Feifan
    Wang, Qingfu
    Zhang, Jian
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (10) : 2061 - 2070
  • [43] Systematic Review and Meta-Analysis on Incidence of Altered Sensation of Mandibular Implant Surgery
    Lin, Chia-Shu
    Wu, Shih-Yun
    Huang, Hsin-Yi
    Lai, Yu-Lin
    PLOS ONE, 2016, 11 (04):
  • [44] Immediate implant placement with flap or flapless surgery: A systematic review and meta-analysis
    Pitman, Jeremy
    Christiaens, Veronique
    Callens, Jeroen
    Glibert, Maarten
    Seyssens, Lorenz
    Blanco, Juan
    Cosyn, Jan
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, : 755 - 764
  • [45] Incisional Hernia Rates After Laparoscopic or Open Abdominal Surgery-A Systematic Review and Meta-Analysis
    Koessler-Ebs, Julia B.
    Grummich, Kathrin
    Jensen, Katrin
    Huettner, Felix J.
    Mueller-Stich, Beat
    Seiler, Christoph M.
    Knebel, Phillip
    Buechler, Markus W.
    Diener, Markus K.
    WORLD JOURNAL OF SURGERY, 2016, 40 (10) : 2319 - 2330
  • [46] Diagnostic accuracy of clinical tests of the hip: a systematic review with meta-analysis
    Reiman, Michael P.
    Goode, Adam P.
    Hegedus, Eric J.
    Cook, Chad E.
    Wright, Alexis A.
    BRITISH JOURNAL OF SPORTS MEDICINE, 2013, 47 (14) : 893 - 902
  • [47] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Angkoon Khaohoen
    Warit Powcharoen
    Tanapon Sornsuwan
    Pisaisit Chaijareenont
    Chaiy Rungsiyakull
    Pimduen Rungsiyakull
    BMC Oral Health, 24
  • [48] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Khaohoen, Angkoon
    Powcharoen, Warit
    Sornsuwan, Tanapon
    Chaijareenont, Pisaisit
    Rungsiyakull, Chaiy
    Rungsiyakull, Pimduen
    BMC ORAL HEALTH, 2024, 24 (01)
  • [49] Accuracy of clinical diagnosis of Parkinson disease A systematic review and meta-analysis
    Rizzo, Giovanni
    Copetti, Massimiliano
    Arcuti, Simona
    Martino, Davide
    Fontana, Andrea
    Logroscino, Giancarlo
    NEUROLOGY, 2016, 86 (06) : 566 - 576
  • [50] Fenoldopam to prevent acute kidney injury after major surgery-a systematic review and meta-analysis
    Gillies, Michael A.
    Kakar, Vivek
    Parker, Robert J.
    Honore, Patrick M.
    Ostermann, Marlies
    CRITICAL CARE, 2015, 19