CLINICAL FACTORS AFFECTING THE ACCURACY OF GUIDED IMPLANT SURGERY-A SYSTEMATIC REVIEW AND META-ANALYSIS

被引:145
|
作者
Zhou, Wenjuan [1 ,2 ,3 ]
Liu, Zhonghao [1 ]
Song, Liansheng [2 ]
Kuo, Chia-Ling [4 ]
Shafer, David M. [2 ]
机构
[1] Binzhou Med Univ, Yantai Stomatol Hosp, Dept Implant Dent, Yantai, Peoples R China
[2] UConn Sch Dent Med, Div Oral & Maxillofacial Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[3] Med Univ Vienna, Univ Clin Dent, Competent Ctr Periodontal Res, Div Conservat Dent & Periodontol, Vienna, Austria
[4] UConn Hlth, CT Inst Clin & Translat Sci, Farmington, CT USA
关键词
Dental implants; Computer-assisted; Guided surgery; Surgical guides; Accuracy; CONE-BEAM CT; STEREOLITHOGRAPHIC SURGICAL TEMPLATES; COMPUTED-TOMOGRAPHY; DENTAL IMPLANTS; PLACEMENT; COMPLICATIONS; RELIABILITY; NAVIGATION; POSITIONS; DEVIATION;
D O I
10.1016/j.jebdp.2017.07.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To systematically review the current dental literature regarding clinical accuracy of guided implant surgery and to analyze the involved clinical factors. Material and Methods PubMed and Cochrane Central Register of Controlled Trials were searched. Meta-analysis and meta-regression analysis were performed. Clinical studies with the following outcome measurements were included: (1) angle deviation, (2) deviation at the entry point, and (3) deviation at the apex. The involved clinical factors were further evaluated. Results Fourteen clinical studies from 1951 articles initially identified met the inclusion criteria. Meta-regression analysis revealed a mean deviation at the entry point of 1.25 mm (95% confidence interval [CI]: 1.22-1.29), 1.57 mm (95% CI: 1.53-1.62) at the apex, and 4.1 degrees in angle (95% CI: 3.97-4.23). A statistically significant difference (P<.001) was observed in angular deviations between the maxilla and mandible. Partially guided surgery showed a statistically significant greater deviation in angle (P<. 001), at the entry point (P<. 001), and at the apex (P<. 001) compared with totally guided surgery. The outcome of guided surgery with flapless approach indicated significantly more accuracy in angle (P<. 001), at the entry point (P<.001), and at apex (P<.001). Significant differences were observed in angular deviation based on the use of fixation screw (P<. 001). Conclusions The position of guide, guide fixation, type of guide, and flap approach could influence the accuracy of computer-aided implant surgery. A totally guided system using fixation screws with a flapless protocol demonstrated the greatest accuracy. Future clinical research should use a standardized measurement technique for improved accuracy.
引用
收藏
页码:28 / 40
页数:13
相关论文
共 50 条
  • [1] Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis
    Wei, Shi-Min
    Zhu, Yu
    Wei, Jian-Xu
    Zhang, Chu-Nan
    Shi, Jun-Yu
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 383 - 393
  • [2] Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies
    Bover-Ramos, Fernando
    Vina-Almunia, Jose
    Cervera-Ballester, Juan
    Penarrocha-Diago, Miguel
    Garcia-Mira, Berta
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 101 - 115
  • [3] Influence of clinical and technical parameters on accuracy of guided implant placement. Systematic review and meta-analysis
    Kasradze, D.
    Segalyte, E.
    Kubilius, R.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 198 - 219
  • [4] Accuracy of robotic surgery for dental implant placement: A systematic review and meta-analysis
    Wu, Xin-Yu
    Shi, Jun-Yu
    Qiao, Shi-Chong
    Tonetti, Maurizio S.
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 598 - 608
  • [5] The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis
    Putra, Ramadhan Hardani
    Yoda, Nobuhiro
    Astuti, Eha Renwi
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 29 - 39
  • [6] Accuracy of robotic computer-assisted implant surgery in clinical studies: a systematic review and meta-analysis
    Zixin Luo
    An Li
    Alexey Unkovskiy
    Jiang Li
    Florian Beuer
    Zhe Wu
    Ping Li
    BMC Oral Health, 25 (1)
  • [7] The Volume Effect in Liver Surgery-A Systematic Review and Meta-analysis
    Richardson, Arthur J.
    Pang, Tony C. Y.
    Johnston, Emma
    Hollands, Michael J.
    Lam, Vincent W. T.
    Pleass, Henry C. C.
    JOURNAL OF GASTROINTESTINAL SURGERY, 2013, 17 (11) : 1984 - 1996
  • [8] Peripheral parenteral nutrition in surgery-a systematic review and meta-analysis
    Khan, Ayman
    Laing, Erin
    Beaumont, Anna
    Wong, Jean
    Warrier, Satish
    Heriot, Alexander
    CLINICAL NUTRITION ESPEN, 2023, 54 : 337 - 348
  • [9] The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis
    Tahmaseb, Ali
    Wu, Viviane
    Wismeijer, Daniel
    Coucke, Wim
    Evans, Christopher
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 416 - 435
  • [10] Tranexamic acid use in meningioma surgery-A systematic review and meta-analysis
    Clynch, Abigail L.
    Gillespie, Conor S.
    Richardson, George E.
    Mustafa, Mohammad A.
    Islim, Abdurrahman I.
    Keshwara, Sumirat M.
    Bakhsh, Ali
    Kumar, Siddhant
    Zakaria, Rasheed
    Millward, Christopher P.
    Mills, Samantha J.
    Brodbelt, Andrew R.
    Jenkinson, Michael D.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2023, 110 : 53 - 60