Balanced detection spectral domain optical coherence tomography with a multiline single camera for signal-to-noise ratio enhancement

被引:10
|
作者
Kuo, Wen-Chuan [1 ,2 ]
Lai, Yune-Shee [3 ]
Lai, Chih-Ming [4 ]
Huang, Yi-Shiang [1 ,3 ]
机构
[1] Natl Yang Ming Univ, Inst Biophoton, Taipei, Taiwan
[2] Natl Yang Ming Univ, Biophoton & Mol Imaging Res Ctr BMIRC, Taipei 112, Taiwan
[3] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 106, Taiwan
[4] Ming Chuan Univ, Dept Elect Engn, Tao Yuan 333, Taiwan
关键词
INTERFEROMETRY; LASER;
D O I
10.1364/AO.51.005936
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, the use and advantages of balanced detection (BD) in spectral domain optical coherence tomography (SD-OCT) are demonstrated. A-scans are calculated as a combination of two phase-opposed interferometric spectra acquired simultaneously by using a multiline single camera spectrometer. Not only does this system suppress artifacts due to autocorrelation, but also the signal of interest is increased by a factor of 2 as experimentally verified. Our BD-based SD-OCT gives a signal-to-noise ratio improvement of 8-14 dB for the peak within 1 mm compared to standard SD-OCT using a single detection scheme. This method is validated by experimental measurement of a glass plate. c 2012 Optical Society of America
引用
收藏
页码:5936 / 5940
页数:5
相关论文
共 50 条
  • [31] Maximization of signal-to-noise ratio in optical coherence tomography using a depth-dependent matched filter
    Boroomand, Ameneh
    Smith, Michael S. D.
    Popescu, Dan P.
    Sowa, Michael
    Sherif, Sherif S.
    PHOTONICS NORTH 2012, 2012, 8412
  • [32] Gradient mapping of multi-timescale optical coherence tomography angiography signals for enhancing signal-to-noise ratio of flow detection
    Nakamichi, Yu
    Journal of Biomechanical Science and Engineering, 2023, 18 (02):
  • [33] Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography
    Li, Xiaolu
    Han, Jae-Ho
    Liu, Xuan
    Kang, Jin U.
    APPLIED OPTICS, 2008, 47 (27) : 4833 - 4840
  • [34] Enhancing the signal-to-noise ratio in ophthalmic optical coherence tomography by image registration - method and clinical examples
    Jorgensen, Thomas Martini
    Thomadsen, Jakob
    Christensen, Ulrik
    Soliman, Wael
    Sander, Birgit
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)
  • [35] Balanced detection for spectral domain optical coherence tomography with fiber-based phase shifter
    Lee, Seung Seok
    Kim, Ju Ha
    Ma, Hye Jun
    Choi, Eun Seo
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XVIII, 2018, 10488
  • [36] Noise of supercontinuum sources in spectral domain optical coherence tomography
    Jensen, Mikkel
    Gonzalo, Ivan Bravo
    Engelsholm, Rasmus Dybbro
    Maria, Michael
    Israelsen, Niels Moller
    Podoleanu, Adrian
    Bang, Ole
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2019, 36 (02) : A154 - A160
  • [37] Full-range spectral domain Jones matrix optical coherence tomography using a single spectral camera
    Fan, Chuanmao
    Yao, Gang
    OPTICS EXPRESS, 2012, 20 (20): : 22360 - 22371
  • [38] Balanced Detection for Self-mixing Interferometry to Improve Signal-to-noise Ratio
    Zhao, Changming
    Norgia, Michele
    Li, Kun
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: ADVANCED LASER TECHNOLOGY AND APPLICATIONS, 2017, 10619
  • [39] Enhancement of signal-to-noise ratio during the detection of weak video pulses
    Makarenko A.S.
    Radioelectronics and Communications Systems, 2010, 53 (10) : 566 - 568
  • [40] Effect of Spectral Signal-to-Noise Ratio on Resolution Enhancement at Surface Plasmon Resonance
    Ma, Long
    Xia, Guo
    Jin, Shiqun
    Bai, Lihao
    Wang, Jiangtao
    Chen, Qiaoqin
    Cai, Xiaobo
    SENSORS, 2021, 21 (02) : 1 - 12