Determining Indoor Air Quality in Gymnasium for Indoor Recreation Activity at University Teknologi MARA, Shah Alam

被引:2
|
作者
Hashim, N. H. Mohd [1 ,2 ]
Ismail, W. H. Wan [3 ]
Sulaiman, F. R. [4 ]
Mokhtar, M. A. S. [3 ]
机构
[1] Univ Teknol MARA, Inst Qual & Knowledge Adv, Shah Alam, Selangor, Malaysia
[2] Univ Teknol MARA, Fac Architecture Planning & Surveying, Shah Alam, Selangor, Malaysia
[3] Univ Teknol MARA, Inst Postgrad Studies, Shah Alam, Selangor, Malaysia
[4] Univ Teknol MARA Cawangan Pahang, Fac Appl Sci, Bandar Jengka, Pahang, Malaysia
来源
4TH INTERNATIONAL CONFERENCE ON RESEARCH METHODOLOGY FOR BUILT ENVIRONMENT AND ENGINEERING 2019 | 2019年 / 385卷
关键词
D O I
10.1088/1755-1315/385/1/012034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study is conducted to determine the indoor air quality in the Faculty Sport and Recreation's gymnasium, UiTM Shah Alam. The objective of the study is to determine possible type and cause of pollutant, determining the health and performance of occupants and assess whether the IAQ parameters comply with the standards set by DOSH. The study consists of questionnaire survey, walkthrough assessment and reading measurement. A total of 350 questionnaires were distributed to the gymnasium users and a walkthrough assessment were conducted at the surrounding area of the gym in order to identify the possible sources of pollutants as well as the reading of selected parameter of IAQ. Several criteria of indoor air quality parameter are identified and measured. Result indicated that concentration of carbon dioxide increases in relation with the number of the occupant. As a conclusion, indoor air quality in the gymnasium is merely complying with DOSH standards. Thus, relevant actions should be taken pertaining to the quality of indoor air in a gymnasium for the betterment of healthy lifestyle.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Thermal comfort and Indoor Air Quality assessment in university classrooms
    Papadopoulos, Giannis
    Panaras, Giorgos
    Tolis, Evangelos
    SUSTAINABILITY IN THE BUILT ENVIRONMENT FOR CLIMATE CHANGE MITIGATION (SBE19), 2020, 410
  • [22] Assessing Air Quality in Various Indoor Environments of a University Library
    Limmongkon, Yuparat
    Pruktharathikul, Vichai
    Jirapornkul, Chananya
    Boonruksa, Pongsit
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2024, 33 (03): : 3283 - 3292
  • [23] Statistical Evaluation of Indoor Air Quality Parameters in Classrooms of a University
    Argunhan, Zeki
    Avci, Ali Serkan
    ADVANCES IN METEOROLOGY, 2018, 2018
  • [24] RELATING ACTUAL AND EFFECTIVE VENTILATION IN DETERMINING INDOOR AIR-QUALITY
    SHERMAN, MH
    WILSON, DJ
    BUILDING AND ENVIRONMENT, 1986, 21 (3-4) : 135 - 144
  • [25] ASSESSMENT OF INDOOR AIR QUALITY LEVEL AND SICK BUILDING SYNDROME ACCORDING TO THE AGES OF BUILDING IN UNIVERSITI TEKNOLOGI MALAYSIA
    Ahmad, Norhidayah
    Hassim, Mimi H.
    JURNAL TEKNOLOGI, 2015, 76 (01): : 163 - 170
  • [26] An improved cohesive hierarchical clustering for indoor air quality monitoring in smart gymnasium with healthy sport areas
    Liu, Long
    Zheng, Fenghe
    ALEXANDRIA ENGINEERING JOURNAL, 2024, 105 : 204 - 217
  • [27] Cooking generated particles’ impact on indoor air quality of university cafeteria
    Kang Zhao
    Xin Zhou
    Bin Zhao
    Building Simulation, 2010, 3 : 15 - 23
  • [28] Assessment of indoor air quality at a university hospital using CFD and GIS
    Cosgun, A.
    Koyun, T.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2025,
  • [29] A Study of Indoor Air Quality of Public Toilet in University's Building
    Asmi, Ade
    Putra, Jouvan Chandra Pratama
    Rahman, Ismail Bin Abdul
    2012 IEEE COLLOQUIUM ON HUMANITIES, SCIENCE & ENGINEERING RESEARCH (CHUSER 2012), 2012,
  • [30] Metrics on Perception,concentration and Characterization of Indoor Air Quality in a University Library
    Morantes, Giobertti
    Rincon, Gladys
    Jones, Benjamin
    INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,