On the energy potential of daytime radiative cooling for urban heat island mitigation

被引:36
|
作者
Carlosena, Laura [1 ,2 ,4 ]
Ruiz-Pardo, Alvaro [3 ]
Feng, Jie [4 ]
Irulegi, Olatz [1 ]
Hernandez-Minguillon, Rufino J. [1 ,2 ]
Santamouris, Mattheos [4 ,5 ]
机构
[1] Univ Basque Country UPV EHU, Architecture Dept, Plaza Onati 2, San Sebastian 20018, Spain
[2] Alonso Hernandez & Asociados Arquitectura SL, Pamplona 31006, Spain
[3] Univ Cadiz, Dept Thermal Machines & Engines, Av Univ Cadiz 10, Puerto Real 11519, Spain
[4] Univ New South Wales, Fac Built Environm, Sydney, NSW 2052, Australia
[5] Univ New South Wales, Anita Lawrence Chair High Performance Architectur, Sydney, NSW 2052, Australia
关键词
Daytime radiative cooling; Sensitivity analysis; Spectrally selective materials; Cooling potential; Urban Heat Island; BUILT ENVIRONMENT; PERFORMANCE; CLIMATE; SYSTEM; GREEN; ROOFS; NIGHT; BUILDINGS; IMPACT; PARAMETERIZATION;
D O I
10.1016/j.solener.2020.08.015
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The objective of this paper is to present the potential of daytime radiative cooling materials as a strategy to mitigate the Urban Heat Island effect. To evaluate the cooling potential of daytime radiative cooling materials, 15 theoretical materials and seven existing materials were simulated: two radiative cooling materials, a cool-material, two white paints, a thermochromic paint and a construction material. The novelty of this study is that it shows that the optimal spectral characteristics of radiative cooling materials depending on the climate conditions and the type of application. A sensitivity analysis was performed to evaluate the impact of each wavelength emissivity on the ability to achieve sub-ambient radiative cooling. The sensitivity analysis comprised a total of 90 theoretical materials with 15 different wavelength combinations and 6 emissivity values. The heat transfer model, which includes conduction, convection, and radiation, was developed using a spectrally-selective sky model. Two conditions were considered: a very conductive surface and a highly insulated one. All the materials were simulated in two cities that suffer from the Urban Heat Island effect-Phoenix and Sydney. The mean surface temperature reduction achieved was 5.30 degrees C in Phoenix and 4.21 degrees C in Sydney. The results presented suggest that the type of application (active or passive) is a determinant factor in the design of radiative cooling materials. Modifying the spectra of the materials led to a substantial change in the cooling potential. A material that performs well in a dry climate as a passive solution could perform poorly as an active solution.
引用
收藏
页码:430 / 444
页数:15
相关论文
共 50 条
  • [21] Mitigation of urban heat island effect and greenroofs
    Lee, Jong Soo
    Kim, Jeong Tai
    Lee, Myung Gi
    [J]. INDOOR AND BUILT ENVIRONMENT, 2014, 23 (01) : 62 - 69
  • [22] On the cooling energy impacts of combined urban heat mitigation strategies in subtropical urban building environment
    Mohammed, Afifa
    Khan, Ansar
    Khan, Hassan Saeed
    Santamouris, Mattheos
    [J]. ENERGY AND BUILDINGS, 2024, 309
  • [23] Scaling the Daytime Urban Heat Island and Urban-Breeze Circulation
    Hidalgo, Julia
    Masson, Valery
    Gimeno, Luis
    [J]. JOURNAL OF APPLIED METEOROLOGY AND CLIMATOLOGY, 2010, 49 (05) : 889 - 901
  • [24] Mapping and Analyzing the Park Cooling Intensity in Mitigation of Urban Heat Island Effect in Lahore, Pakistan
    Hanif, Aysha
    Nasar-U-Minallah, Muhammad
    Zia, Sahar
    Ashraf, Iqra
    [J]. KOREAN JOURNAL OF REMOTE SENSING, 2022, 38 (01) : 127 - 137
  • [25] Assessing the Cooling Effect of Blue-Green Spaces: Implications for Urban Heat Island Mitigation
    Pritipadmaja
    Garg, Rahul Dev
    Sharma, Ashok K.
    [J]. WATER, 2023, 15 (16)
  • [26] Urban environment and vegetation: comfort and urban heat island mitigation
    Magliocco, Adriano
    Perini, Katia
    [J]. TECHNE-JOURNAL OF TECHNOLOGY FOR ARCHITECTURE AND ENVIRONMENT, 2014, 8 : 155 - 162
  • [27] Is the Urban Heat Island intensity relevant for heat mitigation studies?
    Martilli, Alberto
    Krayenhoff, E. Scott
    Nazarian, Negin
    [J]. URBAN CLIMATE, 2020, 31
  • [28] Environmental effect on the performance of passive daytime photonic radiative cooling and building energy-saving potential
    Bijarniya, Jay Prakash
    Sarkar, Jahar
    Maiti, Pralay
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 274
  • [29] Experimental evaluation of urban heat island mitigation potential of retro-reflective pavement in urban canyons
    Rossi, Federico
    Castellani, Beatrice
    Presciutti, Andrea
    Morini, Elena
    Anderini, Elisabetta
    Filipponi, Mirko
    Nicolini, Andrea
    [J]. ENERGY AND BUILDINGS, 2016, 126 : 340 - 352
  • [30] For the mitigation of urban heat island and urban noise island: two simultaneous sides of urban discomfort
    Kousis, I
    Pisello, A. L.
    [J]. ENVIRONMENTAL RESEARCH LETTERS, 2020, 15 (10):