Long-term survival and complications in patients with malignant ventricular tachyarrhythmias: Treatment with a nonthoracotomy implantable cardioverter defibrillator with or without a subcutaneous patch

被引:7
|
作者
Jafar, MZ [1 ]
Schloss, EJ [1 ]
Mehdirad, AA [1 ]
Keim, S [1 ]
Rist, K [1 ]
Siddiqui, S [1 ]
Tchou, PJ [1 ]
机构
[1] UNIV PITTSBURGH,MED CTR,PITTSBURGH,PA
来源
关键词
implantable defibrillator; nonthoracotomy system; ventricular arrhythmias;
D O I
10.1111/j.1540-8159.1997.tb06784.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Endotak lead system and ICD has been used to treat patients with malignant ventricular arrhythmias. We analyzed the clinical characteristics of 1,053 patients who underwent implantation of the Endotak lead system with or without a subcutaneous patch. Group A consisted of 567 patients receiving the Endotak lead with a subcutaneous patch; group B consisted of 486 patients receiving the Endotak lead alone. The 2-year survivals from sudden death, cardiac death, and total death in groups A and B were 97.6%/98.2% (P = 0.38), 88.6%/92.7% (P = 0.09), and 84.7%/86.8% (P = 0.06), respectively. Minimum tested effective defibrillation energy at implantation was 17.2 +/- 5.2 J for group A and 15.8 +/- 5.1 J for group B (P < 0.01). The operative mortality was 1.8% in group A and 0.6% in group B (P = 0.09). The incidence of lead dislodgment, malfunction, and infection was 6.7% for group A and 3.5% for group B (P < 0.02), Sudden death survival was excellent in both groups with less lead complications in group B. The Endofak lead alone may be the preferred choice of lead configuration in those patients who have adequate defibrillation thresholds at implant.
引用
收藏
页码:1305 / 1311
页数:7
相关论文
共 50 条
  • [21] Long-Term Safety and Efficacy of the Subcutaneous Implantable Cardioverter-Defibrillator System
    Steinberg, Jonathan S.
    Kutyifa, Valentina
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (05) : 398 - 400
  • [22] TREATMENT OF MALIGNANT VENTRICULAR ARRHYTHMIAS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    SLATER, AD
    SINGER, I
    STAVENS, CS
    ZEECHENG, C
    GANZEL, BL
    KUPERSMITH, J
    MAVROUDIS, C
    GRAY, LA
    [J]. ANNALS OF SURGERY, 1989, 209 (05) : 635 - 641
  • [23] LONG-TERM MULTICENTER EXPERIENCE WITH A 2ND-GENERATION IMPLANTABLE PACEMAKER-DEFIBRILLATOR IN PATIENTS WITH MALIGNANT VENTRICULAR TACHYARRHYTHMIAS
    SAKSENA, S
    POCZOBUTTJOHANOS, M
    CASTLE, LW
    FOGOROS, RN
    ALPERT, BL
    KRON, J
    PACIFICO, A
    GRIFFIN, J
    RUSKIN, JN
    KEHOE, RF
    YEE, R
    DORIAN, P
    KERR, CR
    LUCERI, RM
    POLISENO, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (03) : 490 - 499
  • [24] Long-term Arrhythmia Variability after Monomorphic Ventricular Tachycardia in Patients with an Implantable Cardioverter Defibrillator
    Clemens, Marcell
    Nagy-Balo, Edina
    Herczku, Csaba
    Kun, Csaba
    Edes, Istvan
    Csanadi, Zoltan
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (10): : 1185 - 1191
  • [25] Long-term outcomes after ablation of ventricular tachycardia in patients with an implantable cardioverter-defibrillator
    Bunch, Thomas J.
    Friedman, Paul A.
    Gersh, Bernard J.
    Asirvatham, Samuel J.
    Brady, Peter A.
    Cha, Yong-Mei
    Jahangir, Arshad
    Mahapatra, Srijoy
    Monahan, Kristi
    Munger, Thomas M.
    Packer, Douglas L.
    Rea, Robert F.
    Shen, Win K.
    Hammill, Stephen C.
    [J]. CIRCULATION, 2006, 114 (18) : 654 - 654
  • [26] Psychological vulnerability, ventricular tachyarrhythmias and mortality in implantable cardioverter defibrillator patients: is there a link?
    Pedersen, Susanne S.
    Brouwers, Corline
    Versteeg, Henneke
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (04) : 377 - 388
  • [27] Circadian pattern of spontaneous ventricular tachyarrhythmias in patients with implantable cardioverter-defibrillator
    Fries, R
    Heisel, A
    Jung, J
    Stopp, M
    Schieffer, H
    Ozbek, C
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 (02): : 140 - 147
  • [29] CLINICAL OUTCOME OF PATIENTS WITH MALIGNANT VENTRICULAR TACHYARRHYTHMIAS AND A MULTIPROGRAMMABLE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTED WITH OR WITHOUT THORACOTOMY - AN INTERNATIONAL MULTICENTER STUDY
    AHERN, TS
    ALPERT, BL
    BARDY, GH
    BECKMAN, K
    BENDITT, DG
    BERENBOM, LD
    BHANDARI, AK
    BRODINE, WN
    CASSIDY, DM
    CHAPMAN, PD
    CHILSON, DA
    DENKER, ST
    ECHT, DS
    EDEL, TB
    FISHER, JD
    FLETCHER, RD
    FOGOROS, RN
    FURMAN, S
    GALLASTEGUI, JL
    GOHN, DC
    GOTTLIEB, CD
    GREER, GS
    GRIFFIN, JC
    HAFFAJEE, CI
    HAMMILL, SC
    HAYES, JJ
    HUANG, SKS
    SMITH, I
    IRWIN, JM
    JACKMAN, WM
    JANOSIK, DL
    JOSEPHSON, M
    KENNEDY, EE
    KOPELMAN, HA
    KREMERS, MS
    KRON, J
    LEHMAN, MH
    LEON, AR
    LINDSAY, BD
    LUCERI, RM
    LUDMER, PL
    MAHMUD, R
    MATTIONI, TA
    MCCLELLAND, JH
    MCCOWAN, RJ
    MILES, WM
    MORADY, F
    NACCARELLI, GV
    OSBORN, JS
    OTOOLE, MF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (07) : 1521 - 1530
  • [30] EVALUATION OF TREATMENT STRATEGIES OF MALIGNANT VENTRICULAR TACHYARRHYTHMIAS IN THE ERA OF THE IMPLANTABLE DEFIBRILLATOR
    DOMANSKI, MJ
    SAKSENA, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (05): : 455 - 457