PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence

被引:56
|
作者
Campbell, Peter G. [1 ]
Cavanaugh, David A. [1 ]
Nunley, Pierce [1 ]
Utter, Philip A. [1 ]
Kerr, Eubulus [1 ]
Wadhwa, Rishi [1 ]
Stone, Marcus [1 ]
机构
[1] Spine Inst Louisiana, Shreveport, LA 71101 USA
关键词
XLIF; LLIF; DLIF; direct; extreme; lateral lumbar interbody fusion; subsidence; PEEK; titanium; polyetheretherketone; comparative effectiveness; ANTERIOR CERVICAL DISKECTOMY; POLYETHERETHERKETONE; TI;
D O I
10.3171/2020.6.FOCUS20367
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE The authors have provided a review of radiographic subsidence after lateral lumbar interbody fusion (LLIF) as a comparative analysis between titanium and polyetheretherketone (PEEK) cages. Many authors describe a reluctance to use titanium cages in spinal fusion secondary to subsidence concerns due to the increased modulus of elasticity of metal cages. The authors intend for this report to provide observational data regarding the juxtaposition of these two materials in the LLIF domain. METHODS A retrospective review of a prospectively maintained database identified 113 consecutive patients undergoing lateral fusion for degenerative indications from January to December 2017. The surgeons performing the cage implantations were two orthopedic spine surgeons and two neurosurgeons. Plain standing radiographs were obtained at 1-2 weeks, 8-12 weeks, and 12 months postoperatively. Using a validated grading system, interbody subsidence into the endplates was graded at these time points on a scale of 0 to III. The primary outcome measure was subsidence between the two groups. Secondary outcomes were analyzed as well. RESULTS Of the 113 patients in the sample, groups receiving PEEK and titanium implants were closely matched at 57 and 56 patients, respectively. Cumulatively, 156 cages were inserted and recombinant human bone morphogenetic protein-2 (rhBMP-2) was used in 38.1%. The average patient age was 60.4 years and average follow- up was 75.1 weeks. Subsidence in the titanium group in this study was less common than in the PEEK cage group. At early follow-up, groups had similar subsidence outcomes. Statistical significance was reached at the 8- to 12-week and 52-week follow-ups, demonstrating more subsidence in the PEEK cage group than the titanium cage group. rhBMP-2 usage was also highly correlated with higher subsidence rates at all 3 follow-up time points. Age was correlated with higher subsidence rates in univariate and multivariate analysis. CONCLUSIONS Titanium cages were associated with lower subsidence rates than PEEK cages in this investigation. Usage of rhBMP-2 was also robustly associated with higher endplate subsidence. Each additional year of age correlated with an increased subsidence risk. Subsidence in LLIF is likely a response to a myriad of factors that include but are certainly not limited to cage material. Hence, the avoidance of titanium interbody implants secondary solely to concerns over a modulus of elasticity likely overlooks other variables of equal or greater importance.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] Lumbar interbody fusion with threaded titanium cages.: Results on 222 cases
    Leclercq, TA
    Matgé, G
    NEUROCHIRURGIE, 2001, 47 (01) : 25 - 33
  • [42] Threaded titanium cages for lumbar interbody fusions
    Ray, CD
    SPINE, 1997, 22 (06) : 667 - 679
  • [43] Minimally invasive transforaminal lumbar interbody fusion versus oblique lateral interbody fusion for lumbar degenerative disease: a meta-analysis
    Zhang, Qing-Yi
    Tan, Jie
    Huang, Kai
    Xie, Hui-Qi
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [44] Minimally invasive transforaminal lumbar interbody fusion versus oblique lateral interbody fusion for lumbar degenerative disease: a meta-analysis
    Qing-Yi Zhang
    Jie Tan
    Kai Huang
    Hui-Qi Xie
    BMC Musculoskeletal Disorders, 22
  • [45] Lateral Lumbar Interbody Fusion
    Taba, Houtan A.
    Williams, Seth K.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2020, 31 (01) : 33 - +
  • [46] Lateral Lumbar Interbody Fusion
    Pawar, Abhijit
    Hughes, Alexander
    Girardi, Federico
    Sama, Andrew
    Lebl, Darren
    Cammisa, Frank
    ASIAN SPINE JOURNAL, 2015, 9 (06) : 978 - 983
  • [47] Lateral lumbar interbody fusion
    Kanter, Adam S.
    Gandhoke, Gurpreet S.
    NEUROSURGICAL FOCUS, 2013, 35
  • [48] 3D printed titanium banana interbody cages versus titanium-coated PEEK bullet cages for TLIF
    Jacob, Connor C.
    Eaton, Ryan
    Ward, Jacob
    Sette, Katelyn
    Wilson, Seth
    Weber, Matthieu D.
    Duru, Olivia
    Keister, Alexander
    Harrigan, Markus E.
    Grossbach, Andrew J.
    Viljoen, Stephanus
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2025, 249
  • [49] The in vitro stabilising effect of polyetheretherketone cages versus a titanium cage of similar design for anterior lumbar interbody fusion
    M. Spruit
    R. G. Falk
    L. Beckmann
    T. Steffen
    R. M. Castelein
    European Spine Journal, 2005, 14 : 752 - 758
  • [50] In vitro dislocation tendency, stabilizing effect, and subsidence tendency of different lumbar interbody fusion cages
    Kettler, A
    Dietl, R
    Krammer, M
    Lumenta, CB
    Claes, L
    Wilke, HJ
    ORTHOPADE, 2002, 31 (05): : 481 - +