Non-invasive Blood Glucose Measurement Based on mid-Infrared Spectroscopy

被引:0
|
作者
Chen, Yang [1 ]
Liu, Jiang [1 ]
Pan, Zhenni [1 ]
Shimamoto, Shirgeru [1 ]
机构
[1] Waseda Univ, Sch Fundamental Sci & Engn, Tokyo, Japan
关键词
non-invasive; blood Glucose; mid-infrared spectroscopy; diabetes;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Non-invasive Blood Glucose Measurement (NGM) technology is a crucial challenge for not only academic communities but also industrial communities. Therefore, finding an applicable and accurate NGM technology is supportive and desired for patients with hyperglycemia or hypoglycemia. Among various NGM technologies, infrared is considered as the most popular and prospective method. In this paper, the mid-infrared spectroscope is used in the experiment, there are significant differences in transmittance in the range of 3000 similar to 3500 cm(-1) (3333 similar to 2857 nm). The association between mid-infrared spectroscopy transmittance and blood glucose concentration is presented. The infrared with a peak wavelength of 3000 similar to 3500 cm(-1) could be a good solution to measuring the physical signals in the experiment. Besides, an NGM prototype that aims to improve self-management motivation is designed and presented. Mid-infrared is very potential and prospective in NGM research. Also, further investigation and consideration ear needed in future work.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Multiparameter techniques for non-invasive measurement of blood glucose
    Amaral, Carlos F.
    Brischwein, Martin
    Wolf, Bernhard
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 12 - 16
  • [42] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    [J]. OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42
  • [43] Non-invasive Measurement of Blood Glucose by Breath Analysis
    Mansouri, Sofiene
    Boulares, Souhaila
    Alhadidi, Tareq
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (10) : 1457 - 1464
  • [44] Temperature influence on non-invasive blood glucose measurement
    Zhang, Xiqin
    Yeo, Joon Hock
    [J]. OPTICAL DIAGNOSTICS AND SENSING IX, 2009, 7186
  • [45] Tunable mid-infrared laser spectroscopy based on fiber-optic sensor for glucose measurement
    Yu, Songlin
    Li, Dachao
    Chong, Hao
    Sun, Changyue
    Xu, Kexin
    [J]. OPTICAL DIAGNOSTICS AND SENSING XIII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2013, 8591
  • [46] Application of genetic algorithms in fundamental study of non-invasive measurement of human blood glucose concentration with near infrared spectroscopy
    Wang, H
    Li, QB
    Liu, ZY
    Xu, KX
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (07) : 779 - 783
  • [47] Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy
    Priyoti, Anika Tabassum
    Jim, Salman Jubair
    Hossain, Sushmit
    Mahmud, Shafkat
    Salvin, Sujana
    Bhattacharjee, Arnab
    [J]. PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 1 - 4
  • [48] Near-infrared LED based Non-invasive Blood Glucose Sensor
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    [J]. 2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 591 - 594
  • [49] Non-invasive blood glucose measurement of 95% certainty by pressure regulated Mid-IR
    Chen, Jason Yuanzhe
    Zhou, Qi
    Xu, Gu
    Wang, Ryan Taoran
    Tai, Edward Guangqing
    Xie, Longhan
    Zhang, Qianzhi
    Guan, Yanyan
    Huang, Xiaochun
    [J]. TALANTA, 2019, 197 : 211 - 217
  • [50] INFLUENCE OF THE STRATUM CORNEUM THICKNESS ON NON-INVASIVE GLUCOSE MEASUREMENT BY MIDDLE INFRARED PHOTOACOUSTIC SPECTROSCOPY
    von Lilienfeld-Toal, H.
    Lieblein, T.
    Bauer, A.
    Hertzberg, O.
    Pleitez, M.
    Maentele, W.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A80 - A80