Comparison of univariate and multivariate strategies for the determination of sucrose in fruit juices by automated flow injection analysis with Fourier transform infrared detection

被引:14
|
作者
Kellner, R
Lendl, B
Wells, I
Worsfold, PJ
机构
[1] UNIV PLYMOUTH,DEPT ENVIRONM SCI,PLYMOUTH PL4 8AA,DEVON,ENGLAND
[2] VIENNA TECH UNIV,INST ANALYT CHEM,A-1060 VIENNA,AUSTRIA
关键词
flow injection; Fourier transform infrared; sucrose; immobilized enzyme; beta-fructosidase; multivariate calibration; partial least-squares; quantitative analysis;
D O I
10.1366/0003702971939929
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An automated technique for the determination of sucrose by flow injection analysis with Fourier transform infrared detection is presented, Two approaches to the quantitation of sucrose in synthetic and real sample matrices have been explored, The first was based on the on-line enzymatic hydrolysis of sucrose to alpha-D-glucose and beta-D-fructose by beta-fructosidase, with difference measurements being performed by using a flow injection manifold with two internally coupled injection valves, The manifold was optimized with time-resolved software and then automated with a custom-built TTL interface to transfer signals from the controlling program to the external apparatus, Univariate calibration was performed on the difference signals between the sucrose samples with and without enzyme hydrolysis, The second approach, using multivariate data analysis, negated the need for sample treatment and produced similar errors for the prediction of sucrose in different matrices within the established linear range of 0 to 100 mM. Both approaches have been successfully applied to the determination of sucrose in fruit juices.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 50 条
  • [1] DETERMINATION OF SUCROSE BY FLOW-INJECTION ANALYSIS WITH FOURIER-TRANSFORM INFRARED DETECTION
    LENDL, B
    KELLNER, R
    [J]. MIKROCHIMICA ACTA, 1995, 119 (1-2) : 73 - 79
  • [2] Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis
    Yann Guémas
    Mohamed Boujtita
    Nabil El Murr
    [J]. Applied Biochemistry and Biotechnology, 2000, 89 : 171 - 181
  • [3] Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis
    Guémas, Y
    Boujtita, M
    El Murr, N
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) : 171 - 181
  • [4] Automated multivariate calibration in sequential injection Fourier transform infrared spectroscopy for sugar analysis
    Schindler, R
    Watkins, M
    Vonach, R
    Lendl, B
    Kellner, R
    Sara, R
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (02) : 226 - 231
  • [5] Determination of amyloglucosidase activity using flow injection analysis with Fourier transform infrared spectrometric detection
    Schindler, R
    Lendl, B
    Kellner, R
    [J]. ANALYST, 1997, 122 (06) : 531 - 534
  • [6] Modulation of the pH in the determination of phosphate with flow injection and Fourier transform infrared detection
    Vonach, R
    Lendl, B
    Kellner, R
    [J]. ANALYST, 1997, 122 (06) : 525 - 530
  • [7] Flow injection Fourier transform infrared determination of nicotine in tobacco
    Garrigues, JM
    Pérez-Ponce, A
    Garrigues, S
    de la Guardia, M
    [J]. ANALYST, 1999, 124 (05) : 783 - 786
  • [8] AQUEOUS FLOW-INJECTION ANALYSIS WITH FOURIER-TRANSFORM INFRARED DETECTION
    MORGAN, DK
    DANIELSON, ND
    KATON, JE
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (16): : 1979 - 1998
  • [9] Flow injection Fourier transform infrared determination of caffeine in coffee
    Bouhsain, Z
    Garrigues, JM
    Garrigues, S
    de la Guardia, M
    [J]. VIBRATIONAL SPECTROSCOPY, 1999, 21 (1-2) : 143 - 150
  • [10] FLOW-INJECTION ANALYSIS WITH FOURIER-TRANSFORM INFRARED DETECTION FOR CLINICAL AND PROCESS ANALYSIS
    ROSENBERG, E
    KELLNER, R
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (8-9): : 530 - 532