Influence of Iterative Reconstruction Algorithms on PET Image Resolution

被引:2
|
作者
Karpetas, G. E. [1 ]
Michail, C. M. [2 ]
Fountos, G. P. [2 ]
Valais, I. G. [2 ]
Nikolopoulos, D. [3 ]
Kandarakis, I. S. [2 ]
Panayiotakis, G. S. [1 ]
机构
[1] Univ Patras, Fac Med, Dept Med Phys, Patras 26500, Greece
[2] Technol Educ Inst Athens, Dept Biomed Engn, Radiat Phys Mat Technol & Biomed Imaging Lab, Athens 12210, Greece
[3] Technol Educ Inst Piraeus, Dept Comp Elect Engn, Athens 12244, Greece
关键词
PET; MTF; image quality; iterative rcconstruction; Monte Carlo; SINGLE-CRYSTAL SCINTILLATORS; NUCLEAR-MEDICINE; LYSO-CE; PERFORMANCE; MTF;
D O I
10.1088/1742-6596/637/1/012011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the present study was to assess image quality of PET scanners through a thin layer chromatography (TLC) plane source. The source was simulated using a previously validated Monte Carlo model. The model was developed by using the GATE MC package and reconstructed images obtained with the STIR software for tomographic image reconstruction. The simulated PET scanner was the GE DiscoveryST. A plane source consisted of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrates, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF). MIT curves were estimated from transverse reconstructed images of the plane source. Images were reconstructed by the maximum likelihood estimation (MLE)-OSMAPOSL, the ordered subsets separable paraboloidal surrogate (OSSPS), the median root prior (MRP) and OSMAPOSL with quadratic prior, algorithms. OSMAPOSL reconstruction was assessed by using fixed subsets and various iterations, as well as by using various beta (hyper) parameter values. MIT values were found to increase with increasing iterations. MIT also improves by using lower beta values. The simulated PET evaluation method, based on the TLC plane source, can be useful in the resolution assessment of PEf scanners.
引用
下载
收藏
页数:4
相关论文
共 50 条
  • [21] Iterative image reconstruction with random correction for PET studies
    Chen, JC
    Liu, RS
    Tu, KY
    Lu, HHS
    Chen, TB
    Chou, KL
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1218 - 1229
  • [22] ALTERNATIVES TO VOXELS FOR IMAGE REPRESENTATION IN ITERATIVE RECONSTRUCTION ALGORITHMS
    LEWITT, RM
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 705 - 716
  • [23] Convergence studies on block iterative algorithms for image reconstruction'
    Guo, Xue-Ping
    APPLIED MATHEMATICS AND COMPUTATION, 2016, 273 : 525 - 534
  • [24] Noise histogram regularization for iterative image reconstruction algorithms
    Thurman, Samuel T.
    Fienup, James R.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (03) : 608 - 617
  • [25] Linear and iterative reconstruction algorithms for a novel PET insert scanner
    Pal, Debashish
    Tai, Yuan-Chuan
    Janecek, Martin
    Wu, Heyu
    O'Sullivan, Joseph A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1938 - 1941
  • [26] Discrete Iterative Algorithms for Scatter-to-Attenuation Reconstruction in PET
    Baker, Yannick
    Schulz, Volkmar
    Karp, Joel S.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [27] Algorithms of super-resolution image reconstruction
    Gomeztagle, Francisco
    Ponomaryov, Volodymyr
    SIXTH INT KHARKOV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER AND SUBMILLIMETER WAVES/WORKSHOP ON TERAHERTZ TECHNOLOGIES, VOLS 1 AND 2, 2007, : 926 - +
  • [28] Reducing CT radiation dose with iterative reconstruction algorithms: The influence of scan and reconstruction parameters on image quality and CTDIvol
    Klink, Thorsten
    Obmann, Verena
    Heverhagen, Johannes
    Stork, Alexander
    Adam, Gerhard
    Begemann, Philipp
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) : 1645 - 1654
  • [29] Efficient methodologies for system matrix modelling in iterative image reconstruction for rotating high-resolution PET
    Ortuno, J. E.
    Kontaxakis, G.
    Rubio, J. L.
    Guerra, P.
    Santos, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07): : 1833 - 1861
  • [30] The influence of a relaxation parameter on SPECT iterative reconstruction algorithms
    Ros, D
    Falcon, C
    Juvells, I
    Pavia, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (05): : 925 - 937