Measured Impedance by Distance Relay for Inter Phase Faults in Presence of TCPST

被引:0
|
作者
Jamali, S. [1 ]
Kazemi, A. [1 ]
Shateri, H. [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran 16846, Iran
关键词
Distance protection; Fault resistance; FACTS devices; Ideal tripping characteristic; Inter phase faults; TCPST;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the effects of Thyristor Controlled Phase Shifter Transformer (TCPST), one of Flexible Alternating Current Transmission System (FACTS) devices, on the measured impedance at the relaying point in the case of the inter phase, phase to phase and three phase, faults. The measured impedance at the relaying point is affected by several factors, including the line pre-fault loading, the line structural conditions, and specially the fault resistance. In the presence of TCPST, in addition to its structural and controlling parameters, its installation point also affects the measured impedance at the relaying point. The variation of the measured impedance for different TCPST installation points and controlling parameters would also be investigated.
引用
下载
收藏
页码:711 / 716
页数:6
相关论文
共 50 条
  • [11] Measured impedance by distance relay in presence of SVC on transmission line
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1515 - +
  • [12] Distance Relay Ideal Tripping Characteristic for Inter Phase Faults in Presence of UPFC on Next Line
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    ISIE: 2009 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, 2009, : 41 - 46
  • [13] Distance Relay Ideal Tripping Characteristic for Inter Phase Faults in Presence of SSSC on Next Line
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    PROCEEDINGS OF ICECE 2008, VOLS 1 AND 2, 2008, : 337 - 342
  • [14] Phase-to-phase distance relay based on the measured impedance trajectory
    Liu, Huanzhang
    Liu, Qiankuan
    Huang, Shaofeng
    Yang, Qixun
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 675 - +
  • [15] Distance relay mal-operation due to presence of SSSC on adjacent lines in inter phase faults
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    2008 IEEE REGION 5 CONFERENCE, 2008, : 180 - 185
  • [16] Measured Impedance by Distance Relay in Presence of Inductive Fault Current Limiter
    Shateri, H.
    Jamali, S.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 578 - +
  • [17] Measured Impedance by Distance Relay in Presence of Resistive Fault Current Limiter
    Jamali, S.
    Shateri, H.
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 753 - 758
  • [18] Measured Impedance at Source Node of a Distribution Feeder for Inter Phase Faults
    Shateri, H.
    Jamali, S.
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [19] Measured Impedance at Relaying Point for Inter Phase Faults on Next Line
    Shateri, H.
    Jamali, S.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 404 - 410
  • [20] Effects of instrument transformers location on measured impedance by distance relay in presence of UPFC
    Jamali, S.
    Kalantar, M.
    Shateri, H.
    2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 715 - +