Measured Impedance by Distance Relay for Inter Phase Faults in Presence of TCPST

被引:0
|
作者
Jamali, S. [1 ]
Kazemi, A. [1 ]
Shateri, H. [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran 16846, Iran
关键词
Distance protection; Fault resistance; FACTS devices; Ideal tripping characteristic; Inter phase faults; TCPST;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the effects of Thyristor Controlled Phase Shifter Transformer (TCPST), one of Flexible Alternating Current Transmission System (FACTS) devices, on the measured impedance at the relaying point in the case of the inter phase, phase to phase and three phase, faults. The measured impedance at the relaying point is affected by several factors, including the line pre-fault loading, the line structural conditions, and specially the fault resistance. In the presence of TCPST, in addition to its structural and controlling parameters, its installation point also affects the measured impedance at the relaying point. The variation of the measured impedance for different TCPST installation points and controlling parameters would also be investigated.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 50 条
  • [1] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of UPFC
    Jamali, S.
    Kazenti, A.
    Shateri, H.
    [J]. 2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 1145 - 1152
  • [2] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of SSSC
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1286 - 1291
  • [3] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of STATCOM
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4323 - 4328
  • [4] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of TCSC on Next Line
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 355 - 360
  • [5] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of Inductive Fault Current Limiter
    Shateri, H.
    Jamali, S.
    [J]. 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1220 - 1226
  • [6] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of SSSC on a Double Circuit Transmission Line
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    [J]. 2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 423 - 428
  • [7] Measured Impedance by Distance Relay in Inter Phase Faults Considering Double Equivalent Model for Line Capacitance
    Shateri, H.
    Jamali, S.
    [J]. 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3537 - 3544
  • [8] Measured Impedance by Distance Relay in Presence of SVC
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (02): : 619 - 627
  • [9] Measured Impedance for Inter Phase Faults in Presence of TCSC Considering MOV Operation
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    [J]. 2008 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE, 2008, : 431 - 437
  • [10] Measured Impedance by Distance Relay in Presence of UPFC on Next Line
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    [J]. 2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 559 - +