Sensitivity maps in three-dimensional magnetic induction tomography

被引:28
|
作者
Soleimani, M [1 ]
机构
[1] Univ Manchester, Sch Mat, William Lee Innovat Ctr, Manchester M60 1QD, Lancs, England
关键词
Eddy current testing;
D O I
10.1784/insi.2006.48.1.39
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Magnetic induction tomography (MIT) attempts to image the electromagnetic characteristics of air object by measuring the mutual inductances between pairs of coils placed around its periphery. MIT is a multiple coil eddy current testing method, so the technique developed in conventional MIT systems can easily be adapted for general eddy current NDT For the image reconstruction in MIT one needs to solve the forward problem as well as the sensitivity maps. In this paper we present three-dimensional sensitivity maps for permeability and conductivity, calculated based on an edge-based finite element software developed for MIT image reconstruction. The differences between sensitivity maps for conductivity and permeability have been studied. The sensitivity maps presented in this paper are the fundamental bases for the image reconstruction in MIT.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [11] A Three-Dimensional Localization System Based on Magnetic Fields and Induction
    Messner, Lukas
    Ussmueller, Thomas
    2024 IEEE TOPICAL CONFERENCE ON WIRELESS SENSORS AND SENSOR NETWORKS, WISNET, 2024, : 5 - 8
  • [12] Sensitivity analysis for magnetic induction tomography
    Soleimani, M
    Jersey-Willuhn, K
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1368 - 1371
  • [13] Three-dimensional optical tomography
    Eppstein, MJ
    Dougherty, DE
    Hawrysz, DJ
    Sevick-Muraca, EM
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 97 - 105
  • [14] Three-dimensional optical tomography
    Eppstein, Margaret J.
    Dougherty, David E.
    Hawrysz, Daniel J.
    Sevick-Muraca, Eva M.
    Proceedings of SPIE - The International Society for Optical Engineering, 3597 : 97 - 105
  • [15] Three-dimensional Magnetic Induction Tomography: Improved Performance for the Center Regions inside a Low Conductive and Voluminous Body
    Klein, Martin
    Erni, Daniel
    Rueter, Dirk
    SENSORS, 2020, 20 (05)
  • [16] Three-Dimensional Magnetic Induction Tomography: Practical Implementation for Imaging throughout the Depth of a Low Conductive and Voluminous Body
    Klein, Martin
    Erni, Daniel
    Rueter, Dirk
    SENSORS, 2021, 21 (22)
  • [17] Three-Dimensional Vascular Maps of the Thalamus
    Antoniello, Daniel
    Fernandez-Torres, Jenelys
    STROKE, 2023, 54 (01) : E9 - E11
  • [18] Three-dimensional maps and subgroup growth
    Rémi Bottinelli
    Laura Ciobanu
    Alexander Kolpakov
    manuscripta mathematica, 2022, 168 : 549 - 570
  • [19] Three-dimensional representations of contour maps
    Lanca, M
    CONTEMPORARY EDUCATIONAL PSYCHOLOGY, 1998, 23 (01) : 22 - 41
  • [20] A Three-Dimensional Generalization of QRT Maps
    Jaume Alonso
    Yuri B. Suris
    Kangning Wei
    Journal of Nonlinear Science, 2023, 33