Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes

被引:80
|
作者
Bonora, B. [1 ]
Maran, A. [1 ]
Ciciliot, S. [1 ]
Avogaro, A. [1 ]
Fadini, G. P. [1 ]
机构
[1] Univ Padua, Div Metab Dis, Dept Med, Via Giustiniani 2, I-35128 Padua, Italy
来源
关键词
Sensors; Continuous glucose monitoring; Hypoglycaemia; Variability; Calibration; BLOOD-GLUCOSE; VARIABILITY; INSTABILITY; ADOLESCENTS; FREQUENCY; ACCURACY; CHILDREN; INDEX;
D O I
10.1007/s40618-016-0495-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous glucose monitoring (CGM) is being increasingly used in clinical practice. The flash glucose monitoring (FGM) and CGM are different systems of interstitial glucose recording. We aimed to determine the agreement between the factory-calibrated FGM FreeStyle Libre (FSL) and the gold-standard CGM Dexcom G4 Platinum (DG4P). We analyzed data from n = 8 outpatients with type 1 diabetes, who wore the FSL and DG4P for up to 14 days during their habitual life. We aligned FSL and DG4P recordings to obtain paired glucose measures. We calculated correlation coefficients, mean absolute relative difference (MARD), percentages in Clarke error grid areas, time spent in hyperglycaemia, target glycaemia, or hypoglycaemia, as well as glucose variability with both sensors. Comparison with self-monitoring of blood glucose (SMBG) was also performed. Patients varied in terms of age, diabetes duration, and HbA1c (from 5.9 to 9.6 %). In the pooled analysis of 10,020 paired values, there was a good correlation between FSL and DG4P (r (2) = 0.76; MARD = 18.1 +/- 14.8 %) with wide variability among patients. The MARD was significantly higher during days 11-14 than in days 1-10, and during hypoglycaemia (19 %), than in normoglycaemia (16 %) or hyperglycaemia (13 %). Average glucose profiles and MARD versus SMBG were similar between the two sensors. Time spent in normo-, hyper-, or hypoglycaemia, and indexes of glucose variability was similarly estimated by the two sensors. In outpatients with type 1 diabetes, we found good agreement between the FSL and DG4P. No significant difference was detected in the estimation of clinical diagnostic parameters.
引用
收藏
页码:1391 / 1399
页数:9
相关论文
共 50 条
  • [31] A head-to-head comparison of four grading systems for oral epithelial dysplasia
    Hankinson, Paul
    Clark, Mollie
    Walsh, Hannah
    Khurram, Syed Ali
    HISTOPATHOLOGY, 2024,
  • [32] A Head-to-head Comparison between SurgiMend and Epiflex in 127 Breast Reconstructions
    Eichler, Christian
    Vogt, Nadine
    Brunnert, Klaus
    Sauerwald, Axel
    Puppe, Julian
    Warm, Mathias
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2015, 3 (06)
  • [33] A Head-to-Head Comparison of the Postprandial Effects of 3 Meal Replacement Beverages Among People With Type 2 Diabetes
    Fonda, Stephanie J.
    Jain, Asha
    Vigersky, Robert A.
    DIABETES EDUCATOR, 2010, 36 (05): : 793 - 800
  • [34] Association between scanning frequency of flash glucose monitoring and continuous glucose monitoring-derived glycemic makers in children and adolescents with type 1 diabetes
    Suzuki, Junichi
    Urakami, Tatsuhiko
    Yoshida, Kei
    Kuwabara, Remi
    Mine, Yusuke
    Aoki, Masako
    Morioka, Ichiro
    PEDIATRICS INTERNATIONAL, 2021, 63 (02) : 154 - 159
  • [35] Discrepancies in Key Metrics of Glycemic Control between Retrospective Continuous Glucose Monitoring System and Flash Glucose Monitoring in Adult Patients with Type 1 Diabetes
    Zhou, Yongwen
    Deng, Hongrong
    Yang, Daizhi
    Yan, Jinhua
    Xu, Wen
    Liu, Hongxia
    Gan, Lu
    Luo, Sihui
    Zheng, Xueying
    Liang, Hua
    Yao, Bin
    Weng, Jianping
    DIABETES, 2020, 69
  • [36] Head-to-head comparison between Actigraph 7164 and GT1M accelerometers in adolescents
    Tanha, Tina
    Tornberg, Asa B.
    Wollmer, Per
    Dencker, Magnus
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (02) : 162 - 165
  • [37] A PK/PD and Metabolic Head-to-Head Comparison of Clinical Doses of Insulin Glargine U300 and Degludec in Type 1 Diabetes
    Lucidi, Paola
    Porcellati, Francesca
    Candeloro, Paola
    Cioli, Patrizia
    Pascucci, Chiara
    Bolli, Geremia B.
    Fanelli, Carmine
    DIABETES, 2019, 68
  • [38] In Silico Head-to-Head Comparison of Insulin Glargine 300 U/mL and Insulin Degludec 100 U/mL in Type 1 Diabetes
    Schiavon, Michele
    Visentin, Roberto
    Giegerich, Clemens
    Sieber, Jochen
    Dalla Man, Chiara
    Cobelli, Claudio
    Klabunde, Thomas
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (08) : 553 - 561
  • [39] A head-to-head-to-head comparison of three bolus calculators in subjects with type 1 diabetes
    Zisser, H. C.
    Wagner, R.
    Pleus, S.
    Haug, C.
    Jendrike, N.
    Parkin, C.
    Freckmann, G.
    DIABETOLOGIA, 2010, 53
  • [40] Performance of Three Continuous Glucose Monitoring Systems in Adults With Type 1 Diabetes
    Eichenlaub, Manuel
    Waldenmaier, Delia
    Wehrstedt, Stephanie
    Pleus, Stefan
    Link, Manuela
    Jendrike, Nina
    Oeter, Suekrue
    Haug, Cornelia
    Schinz, Maren
    Braunack-Mayer, Vincent
    Schneider, Regula
    Brandt, Derek
    Freckmann, Guido
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025,