Multistage high pressure mixer-settler system

被引:3
|
作者
Pietzonka, W
Trepp, C
机构
[1] Institute of Process Engineering and Cryogenics, Swiss Federal Institute of Technology, Zürich
来源
关键词
D O I
10.1016/S0921-8610(96)80104-X
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An extraction apparatus has been developed for pressures up to 30 MPa and temperatures up to 120 degrees C, as an alternative to the counter-current column used in supercritical fluid extraction. The apparatus consists of five mixer-settler stages which are arranged in counter-current flow. Regenerative pumps are used as mixers to achieve an intense contact between the two phases and to create a large mass transfer surface area. Cyclones are used as separators to avoid back mixing. Previous work with a single stage module yielded a separation efficiency of about 96%. The achieved mass transfer surface area was 2'000 - 3'000 m(2)/m(3). The multistage apparatus is currently being tested. Results of separation efficiency and behaviour will therefore be presented at the sysmposium in October 1996.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 50 条
  • [41] Fluid flow characterization of liquid–liquid mixing in mixer-settler
    Mohsen Ostad Shabani
    Mehdi Alizadeh
    Ali Mazahery
    Engineering with Computers, 2011, 27 : 373 - 379
  • [42] COMBINED MIXER-SETTLER UNIT FOR SOLVENT-EXTRACTION MEASUREMENTS
    ECCLES, H
    LAWSON, GJ
    RAWLENCE, DJ
    CHEMISTRY & INDUSTRY, 1975, (14) : 616 - 617
  • [43] Three-phase fluid dynamics simulation of ionic liquid system in mixer-settler
    Tang Q.
    Bao D.
    Shao S.
    Xu P.
    Liu L.
    Zheng W.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (10): : 5468 - 5479
  • [44] Improved Mass Transfer for Supercritical-Fluid Extraction - A New Mixer-Settler System
    Schaffner, D.
    Trepp, C.
    Journal of Supercritical Fluids, 8 (04):
  • [45] Improved mass transfer for supercritical-fluid extraction - A new mixer-settler system
    Schaffner, D
    Trepp, C
    JOURNAL OF SUPERCRITICAL FLUIDS, 1995, 8 (04): : 287 - 294
  • [46] Dynamic modelling of copper solvent extraction mixer-settler units
    Moreno, C. M.
    Perez-Correa, J. R.
    Otero, A.
    MINERALS ENGINEERING, 2009, 22 (15) : 1350 - 1358
  • [47] The effects of a surfactant concentration on the mass transfer in a mixer-settler extractor
    Abolghasemi, Hossein
    Moosavian, Mohammad Ali
    Radpour, Saeid Reza
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2006, 25 (04): : 9 - 15
  • [48] THE COMBINED MIXER-SETTLER - A NEW DEVELOPMENT IN SOLVENT-EXTRACTION
    BONNEY, CF
    ROWDEN, GA
    MCKEE, D
    JOURNAL OF METALS, 1980, 32 (12): : 80 - 80
  • [49] The effects of a surfactant on mean drop size in a mixer-settler extractor
    Khakpay, Amir
    Abolghasemi, Hossein
    Salimi-Khorshidi, Ali
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (06) : 1105 - 1111
  • [50] Mixer-settler based on phase inversion: Design of the mixing zone
    Paulo, Joao B. A.
    Hadjiev, Dimiter E.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (11) : 3821 - 3829