Implantation of second glaucoma drainage devices after failure of primary devices

被引:0
|
作者
Godfrey, DG [1 ]
Krishna, R [1 ]
Greenfield, DS [1 ]
Budenz, DL [1 ]
Gedde, SJ [1 ]
Scott, IU [1 ]
机构
[1] Univ Miami, Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL USA
来源
OPHTHALMIC SURGERY AND LASERS | 2002年 / 33卷 / 01期
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate the efficacy and safety of implantation of a second glaucoma drainage device for eyes that have failed a primary device. PATIENTS AND METHODS: Medical records of patients receiving a primary glaucoma drainage device at Bascom Palmer Eye Institute from January 1987 to October 1998 were reviewed, of which 18 eyes of 18 patients were studied. Patients failing a primary glaucoma drainage procedure and receiving a second glaucoma drainage device were included in this study. The second eye in the same patient was excluded if a second drainage implant was required. All patients received a second device in a standardized fashion with the drainage tube inserted in the anterior chamber. Main outcome measures included: visual acuity, intraocular pressure (IOP), antiglaucomatous medication, length of follow up, and surface area of glaucoma drainage device. Success was defined as an IOP less than or equal to 21 mm Hg with or without medications, and at feast a 20% reduction in IOP, without the need for additional glaucoma procedures. RESULTS: The mean postoperative IOP (19.6 9.4 mm Hg; range, 8-50 mm Hg) was significantly (P 0.006) lower than the mean preoperative IOP (29.5 +/- 8.1 mm Hg; range, 20-52 mm Hg) at last follow up (mean 19.6 +/- 13.6 months; range, 6-47 months). The mean number of postoperative antiglaucomatous medications (2.2 +/- 1.2; range 0-4) was statistically similar (P = 0.2) to mean preoperative number of antiglaucomatous medications (2.6 +/- 1.2, range 1-4). Using Kaplan-Meier estimates, successful IOP reduction was observed in 89%, 83%, 63%, and 37% of eyes at 6 months, 1, 2, and 3 years, respectively. Four patients (21%) had a decline in visual acuity. CONCLUSIONS: Implantation of secondary glaucoma drainage devices may be useful in eyes that have failed primary devices.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [31] Artificial drainage devices for glaucoma surgery: an overview
    Chaudhry, M.
    Grover, S.
    Baisakhiya, S.
    Bajaj, A.
    Bhatia, M. S.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2012, 4 (02) : 295 - 302
  • [32] Magnetic Resonance Imaging of Glaucoma Drainage Devices
    Barao, Rafael Correia
    Berhanu, David
    Matos, Diogo Bernardo
    Barata, Andre Diogo
    Sousa, Rita
    Pinto, Luis Abegao
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [33] The "Three Cherries Technique" for glaucoma drainage devices
    Weber, Constance
    Brinken, Ralf
    Holz, Frank G.
    Mercieca, Karl
    OPHTHALMOLOGIE, 2023, 120 (02): : 216 - 219
  • [34] Glaucoma drainage devices; past, present, and future
    Lim, KS
    Allan, BDS
    Lloyd, AW
    Muir, A
    Khaw, PT
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (09) : 1083 - 1089
  • [35] Revision surgery in episcleral glaucoma drainage devices
    Rosentreter, A.
    Dietlein, T. S.
    OPHTHALMOLOGE, 2016, 113 (11): : 906 - 909
  • [36] Glaucoma drainage devices in children: an updated review
    Vasconcelos, Alex Teles
    Massote, Jose Aloisio
    Senger, Cassia
    Barbieri, Livia Prudente
    Cronemberger, Sebastiao
    Paula, Jayter Silva
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (06)
  • [37] Use of glaucoma drainage devices in the management of glaucoma associated with aniridia
    Arroyave, CP
    Scott, IU
    Gedde, SJ
    Parrish, RK
    Feuer, WJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (02) : 155 - 159
  • [38] Pars plana insertion of glaucoma drainage devices for refractory glaucoma
    de Guzman, MHPU
    Valencia, A
    Farinelli, AC
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (02): : 102 - 107
  • [39] Trainee Glaucoma Surgery: Experience With Trabeculectomy and Glaucoma Drainage Devices
    Connor, Michael A.
    Knape, Robert M.
    Oltmanns, Matthew H.
    Smith, Mary Fran
    OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (05) : 523 - 531
  • [40] Simultaneous placement of 2 glaucoma drainage devices for uncontrolled glaucoma
    Momont, Anna C.
    Stein, Joshua D.
    Lee, Paul P.
    Weizer, Jennifer S.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2014, 49 (02): : 205 - 209