Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum

被引:194
|
作者
Quigley, J. D. [1 ]
Lago, A. [1 ]
Chapman, C. [2 ]
Erickson, P. [2 ]
Polo, J. [3 ]
机构
[1] APC Inc, Ankeny, IA 50021 USA
[2] Univ New Hampshire, Dept Biol Sci, Durham, NH 03824 USA
[3] APC Europe SA, E-08400 Granollers, Spain
关键词
colostrum; immunoglobulin; refractometer; validation; IGG CONCENTRATION; TURBIDIMETRIC IMMUNOASSAY; RADIAL IMMUNODIFFUSION; QUALITY; GRAVITY; TEMPERATURE; MANAGEMENT; HYDROMETER;
D O I
10.3168/jds.2012-5823
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Samples of first-milking MC were collected from 7 dairy farms in Maine, New Hampshire, Vermont, and Connecticut (n = 84) and 1 dairy farm in California (n = 99). The MC was milked from the cow at 6.1 +/- 5.6 h postparturition and a sample was evaluated for Brix percentage by using an optical refractometer. Two additional samples (30 mL) were collected from the milk bucket, placed in vials, and frozen before analysis of total IgG by radial immuno-diffusion (RID) using commercially available plates and by turbidimetric immunoassay (TIA). The second sample was analyzed for total bacterial counts and coliform counts at laboratories in New York (Northeast samples) and California (California samples). The Brix percentage (mean +/- SD) was 23.8 +/- 3.5, IgG concentration measured by RID was 73.4 +/- 26.2 g/L, and IgG concentration measured by TIA was 67.5 +/- 25.0 g/L. The Brix percentage was highly correlated (r = 0.75) with IgG analyzed by RID. The Brix percentage cut point to define high- or low-quality colostrum (50 g of IgG/L measured by RID) that classified more samples correctly given the proportion of high- (86%) and low-quality (14%) samples in this study was 21%, which is slightly lower than other recent estimates of Brix measurements. At this cut point, the test sensitivity, specificity, positive and negative predictive values, and accuracy were 92.9, 65.5, 93.5, 63.3, and 88.5%, respectively. Measurement of IgG by TIA correlated with Brix (r = 0.63) and RID (r = 0.87); however, TIA and RID methods of IgG measurement were not consistent throughout the range of samples tested. We conclude that Brix measurement of total solids in fresh MC is an inexpensive, rapid, and satisfactorily accurate method of estimating IgG concentration. A cut point of 21% Brix to estimate samples of MC > 50 g/L was most appropriate for our data. Measurement of IgG in MC by TIA differed from measurement by RID.
引用
收藏
页码:1148 / 1155
页数:8
相关论文
共 50 条
  • [1] Validation of Brix refractometer to estimate immunoglobulin G concentration in goat colostrum
    Buranakarl, Chollada
    Thammacharoen, Sumpun
    Nuntapaitoon, Morakot
    Semsirmboon, Sapon
    Katoh, Kazuo
    VETERINARY WORLD, 2021, 14 (12) : 3194 - 3199
  • [2] Validation of Brix refractometer to estimate colostrum immunoglobulin G content and composition in the sow
    Hasan, S. M. K.
    Junnikkala, S.
    Valros, A.
    Peltoniemi, O.
    Oliviero, C.
    ANIMAL, 2016, 10 (10) : 1728 - 1733
  • [3] Evaluation of a Brix refractometer to estimate serum immunoglobulin G concentration in neonatal dairy calves
    Deelen, S. M.
    Ollivett, T. L.
    Haines, D. M.
    Leslie, K. E.
    JOURNAL OF DAIRY SCIENCE, 2014, 97 (06) : 3838 - 3844
  • [4] Investigation of brix refractometry for estimating bovine colostrum immunoglobulin G concentration
    Sockett, Donald
    Breuer, Ryan M.
    Smith, Lindsey W.
    Keuler, Nicholas S.
    Earleywine, Thomas
    FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [5] Evaluation of Brix refractometer to assess immunoglobulin G concentration of first and second colostrum from Jersey cows.
    Rolle, D.
    Rodriguez, S.
    Valldecabres, A.
    Silva-del-Rio, N.
    JOURNAL OF ANIMAL SCIENCE, 2016, 94 : 715 - 715
  • [6] Assessment of Brix refractometry to estimate immunoglobulin G concentration in beef cow colostrum
    Gamsjager, Lisa
    Elsohaby, Ibrahim
    Pearson, Jennifer M.
    Levy, Michel
    Pajor, Edmond A.
    Haines, Deborah M.
    Windeyer, M. Claire
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (04) : 1662 - 1673
  • [7] Evaluation of Brix Refractometry to Estimate Immunoglobulin G Content in Buffalo Colostrum and Neonatal Calf Serum
    Giammarco, Melania
    Chincarini, Matteo
    Fusaro, Isa
    Manetta, Anna Chiara
    Contri, Alberto
    Gloria, Alessia
    Lanzoni, Lydia
    Mammi, Ludovica Maria Eugenia
    Ferri, Nicola
    Vignola, Giorgio
    ANIMALS, 2021, 11 (09):
  • [8] The diagnostic accuracy of the Brix refractometer in determining mare colostrum with high and low immunoglobulin G concentrations
    Akkose, Mehmet
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2025, 149
  • [9] BRIX does not accurately estimate immunoglobulin content in colostrum.
    Vermeire, D. A.
    DeKlyen, D. A.
    JOURNAL OF DAIRY SCIENCE, 2022, 105 : 324 - 325
  • [10] Immunoglobulin G concentration in canine colostrum: Evaluation and variability
    Mila, Hanna
    Feugier, Alexandre
    Grellet, Aurelien
    Anne, Jennifer
    Gonnier, Milene
    Martin, Maelys
    Rossig, Lisa
    Chastant-Maillard, Sylvie
    JOURNAL OF REPRODUCTIVE IMMUNOLOGY, 2015, 112 : 24 - 28