Direct superior approach with standard instrumentation for total hip arthroplasty: safety and efficacy in a prospective 200-case series

被引:18
|
作者
Tsiridis, Eleftherios [1 ,2 ]
Kenanidis, Eustathios [1 ,2 ]
Potoupnis, Michael [1 ,2 ]
Sayegh, Fares E. [1 ,2 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Med, Acad Orthopaed Unit, Papageorgiou Gen Hosp, Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Ctr Orthopaed & Regenerat Med CORE, Ctr Interdisciplinary Res & Innovat CIRI, Thessaloniki, Greece
关键词
Direct superior approach; hip approach; hip arthroplasty; iliotibial-band preserving; minimally invasive; standard instrumentation; DIRECT ANTERIOR APPROACH; POSTERIOR APPROACH; SURGICAL APPROACH; OUTCOMES;
D O I
10.1177/1120700019843120
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Direct Superior Approach (DSA) is a muscle sparing approach for total hip arthroplasty (THA) implemented using special instrumentation. There is a lack of information in the literature concerning DSA with standard instrumentation. Materials and methods: 238 patients were recruited for primary THA by a single surgeon from January 2016 until May 2017. 209 patients underwent THA through DSA approach with non-offset acetabular reamers and femoral broaches. We evaluated accuracy of implantation, complications and early functional results. Independent orthopaedic surgeons performed the clinical and radiographic assessments. Results: 200 patients were followed for a year. 3 different implants were used. No sciatic nerve palsies, hip dislocations or fractures were recorded. There was one acute deep and superficial wound infection. The mean functional score was significantly improved at all follow-ups (p< 0.001). 97% of stems were inserted into the neutral coronal and 96% in neutral sagittal alignment. All cups fell within a safe zone of inclination and 91% of anteversion. 2 hips demonstrated heterotopic ossification, Brooker class I. Obese patients had no increased risk of complications. Conclusions: DSA with standard instrumentation is safe and efficacious for THA. It offers fast recovery and facilitates correct implantation of different implants, can be useful even for hip dysplasia and obese patients with minimal complication rates.
引用
收藏
页码:552 / 558
页数:7
相关论文
共 50 条
  • [21] Comparison of clinical efficacy between direct anterior approach and posterolateral approach in primary total hip arthroplasty
    Jin, M. -W.
    Zhang, L.
    Chu, X. -B.
    Lv, S. J.
    Zhang, J. -J.
    Tong, P. -J.
    Pan, Y.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (12) : 5604 - 5613
  • [22] Comparison of a minimally invasive posterior approach and the standard posterior approach for total hip arthroplasty A prospective and comparative study
    Bernd Fink
    Alexander Mittelstaedt
    Martin S. Schulz
    Pavol Sebena
    Joachim Singer
    Journal of Orthopaedic Surgery and Research, 5
  • [23] Comparison of a minimally invasive posterior approach and the standard posterior approach for total hip arthroplasty A prospective and comparative study
    Fink, Bernd
    Mittelstaedt, Alexander
    Schulz, Martin S.
    Sebena, Pavol
    Singer, Joachim
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [24] Direct Anterior Approach Provides Superior Prosthesis Adaptability in the Early Postoperative Period of Total Hip Arthroplasty
    Shen, Jing
    Ji, Ruiqing
    Yao, Sai
    Ruan, Pengfei
    Zhu, Zhouwei
    Wang, Xiang
    Sun, Huihui
    Chen, Jie
    Ruan, Hongfeng
    Ji, Weifeng
    ORTHOPAEDIC SURGERY, 2023, 15 (03) : 679 - 686
  • [25] Total hip arthroplasty using the direct anterior approach and intraoperative neurophysiological monitoring for Crowe III hip dysplasia : surgical technique and case series
    Vanlommel, Jan
    Sutter, Martin
    Leunig, Michael
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (01): : 22 - 27
  • [26] Femoral neuropathy following direct anterior total hip arthroplasty: an anatomic review and case series
    Patton, Ryan S.
    Runner, Robert P.
    Lazarus, David
    Bradbury, Thomas L.
    JOURNAL OF SURGICAL CASE REPORTS, 2018, (09):
  • [27] Efficacy and safety of systemic tranexamic acid administration in total knee arthroplasty: A case series
    Maalouly, Joseph
    El Assaad, Donna
    Ayoubi, Rami
    Tawk, Antonios
    Darwish, Mohammad
    Aouad, Dany
    Lati, Georgio
    Darwish, Mohammad
    El Rassi, George
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2020, 73 : 90 - 94
  • [28] Direct anterior approach in lateral position achieves superior cup orientation in total hip arthroplasty: a radiological comparative study of two consecutive series
    Fei Hu
    Xifu Shang
    Xianzuo Zhang
    Min Chen
    International Orthopaedics, 2020, 44 : 453 - 459
  • [29] Direct anterior approach in lateral position achieves superior cup orientation in total hip arthroplasty: a radiological comparative study of two consecutive series
    Hu, Fei
    Shang, Xifu
    Zhang, Xianzuo
    Chen, Min
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (03) : 453 - 459
  • [30] Single-Incision Direct Anterior Approach for Total Hip Arthroplasty Using a Standard Operating Table
    Lovell, Tim P.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 64 - 68