Sliding DFT Assisted Instantaneous Symmetrical Components Method for Estimating Reference Current to Active Power Filter

被引:0
|
作者
Chandrasekaran, S. [1 ]
Ragavan, K. [1 ]
机构
[1] Indian Inst Technol Gandhinagar, Dept Elect Engn, Gandhinagar, India
来源
2012 IEEE 55TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS) | 2012年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The performance of Active Power Filter (APF) is decided by the reference current estimation technique. This estimation is not straightforward in practice due to the distorted and unbalanced supply; non-linear and unbalanced load. To address such practical situations, a new Sliding Discrete Fourier Transform (SDFT) based technique involving instantaneous symmetrical components and p-q theory is proposed. With this method, the harmonic, fundamental frequency unbalanced and reactive current components are determined. The feature that the SDFT could provide the 90-degree shifted signal together with the symmetrical components is utilized for the purpose of determining the unbalanced current component. Fundamental reactive current is obtained using the widely used instantaneous p-q theory. The effectiveness of the proposed technique is demonstrated through the simulation results pertaining to three phase system with distorted and unbalanced supply.
引用
收藏
页码:1168 / 1171
页数:4
相关论文
共 50 条
  • [21] Comparative Study of Reference Current Generation for Shunt Active Power Filter
    Panchbhai, Anand
    Prajapati, Nikunj
    Parmar, Shreya
    2017 INTERNATIONAL CONFERENCE ON POWER AND EMBEDDED DRIVE CONTROL (ICPEDC), 2017, : 381 - 386
  • [22] An active power filter with harmonic detection method based on recursive DFT
    Srianthumrong, S
    Sangwongwanich, S
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 127 - 132
  • [23] Adaptive Filter to Compute the Reference Current on Shunt Active Power Filters
    Petit, Johann F.
    Robles, Guillermo
    Amaris, Hortensia
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (06): : 2806 - 2815
  • [24] Synchronization of the active power filter current reference to the distorted line voltage
    Nedeljković, D.
    Nastran, J.
    Elektrotehniski Vestnik/Electrotechnical Review, 2001, 68 (01): : 27 - 31
  • [25] Reference active source current for active power filter in an unbalanced three-phase power system via the synchronous detection method
    Chen, C.L.
    Lin, C.E.
    Huang, C.L.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 2 : 502 - 505
  • [26] Analysis of Sinusoidal Current Reference Generation with Flat Instantaneous Active Power for Unbalanced Grids
    Revelo, Salvador
    Perez, Marcelo A.
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 3386 - 3392
  • [27] A Sliding Mode SVPWM Method for a HTS Shunt Active Power Filter
    Li, Youjin
    Zhou, Qian
    Mu, Shuai
    Zhang, Tianlong
    Li, Hao
    Wang, Jian
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)
  • [28] Single-phase power active filter and compensator using instantaneous reactive power method
    Dobrucky, B
    Kim, H
    Racek, V
    Roch, M
    Pokorny, M
    PCC-OSAKA 2002: PROCEEDINGS OF THE POWER CONVERSION CONFERENCE-OSAKA 2002, VOLS I - III, 2002, : 167 - +
  • [29] A simple prediction based current reference generation method for a four-wire active power filter
    Pettersson, Sami
    Routimo, Mikko
    Salo, Mika
    Tuusa, Heikki
    2006 12TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2006, : 406 - +
  • [30] Neural Network Complementary Sliding Mode Current Control of Active Power Filter
    Fei, Juntao
    Liu, Nixuan
    Hou, Shixi
    Fang, Yunmei
    IEEE ACCESS, 2021, 9 : 25681 - 25690