Measurement of the remnant magnetic-field in Lorentz mode using permalloy

被引:1
|
作者
Liu, Haihua [1 ]
Duan, Xiaokun [2 ]
Che, Renchao [1 ]
Wang, Zhifeng [1 ]
Duan, Xiaofeng [1 ]
机构
[1] Chinese Acad Sci, Inst Phys, Beijing Natl Lab Condensed Matter Phys, Beijing Lab Elect Microscopy, Beijing 100190, Peoples R China
[2] Adv Technol & Mat Co Ltd, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Lorentz electron microscopy; Lorentz lens; Remnant magnetic field; Permalloy; Cross-tie walls;
D O I
10.1016/S1006-7191(08)60120-9
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A novel method was reported to measure the remnant magnetic field in Lorentz mode in a FEI Tecnai F20 transmission electron microscope equipped with a Lorentz lens. The movement of the circle Bloch line of the cross-tie wall in Permalloy is used to measure the remnant magnetic field by tilting the specimen and adjusting the objective lens current. The remnant magnetic field is estimated to be about 17 Oe, in a direction opposite to that of the objective lens magnetic field. The remnant magnetic field can be compensated by adjusting the value of the objective lens current.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 50 条
  • [21] NMR MEASUREMENT OF MAGNETIC-FIELD INHOMOGENEITY
    WEIS, Y
    FROLLO, I
    BUDINSKY, L
    MEASUREMENT TECHNIQUES USSR, 1991, 34 (06): : 610 - 613
  • [22] MEASUREMENT OF THE MAGNETIC-FIELD OF THE CDF MAGNET
    NEWMANHOLMES, C
    SCHMIDT, EE
    YAMADA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (03): : 443 - 451
  • [23] MAGNETIC-FIELD MEASUREMENT BY NMR IMAGING
    MAUDSLEY, AA
    SIMON, HE
    HILAL, SK
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (03): : 216 - 220
  • [24] MAGNETIC-FIELD MEASUREMENT OF CORROSION PROCESSES
    MURPHY, JC
    HARTONG, G
    COHN, RF
    MORAN, PJ
    BUNDY, K
    SCULLY, JR
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (02) : 310 - 313
  • [25] Magnetic-field measurements using an integrated resonant magnetic-field sensor
    Kadar, Z
    Bossche, A
    Sarro, PM
    Mollinger, JR
    SENSORS AND ACTUATORS A-PHYSICAL, 1998, 70 (03) : 225 - 232
  • [26] MAGNETIC DIODE FOR MEASUREMENT OF MAGNETIC-FIELD STRENGTH.
    Fedotov, S.I.
    Zalkind, V.M.
    Instruments and experimental techniques New York, 1987, 30 (4 pt 2): : 928 - 930
  • [27] BERNSTEIN MODE FORMATION IN WEAK MAGNETIC-FIELD
    KUZMENKOV, LS
    SITNOV, MI
    PHYSICS LETTERS A, 1984, 100 (03) : 141 - 143
  • [28] OSCILLATIONS OF MAGNETIZATION IN PERMALLOY-FILMS GENERATED BY TRANSVERSAL PULSED MAGNETIC-FIELD
    KHRISTENKO, AI
    SHISHKOV, AG
    ILICHEVA, EN
    KANAVINA, NG
    FIZIKA METALLOV I METALLOVEDENIE, 1972, 34 (06): : 1178 - 1186
  • [29] LOW MAGNETIC-FIELD MEASUREMENT BY NMR USING POLARIZED FLOWING WATER
    KIM, CG
    RYU, KS
    WOO, BC
    KIM, CS
    IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (06) : 3198 - 3200
  • [30] Thickness and magnetic-field dependence of domain switching in isolated and interacting permalloy contacts
    Pels, C
    Barthelmess, M
    Bolte, M
    Thieme, A
    Meier, G
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (03) : 885 - 891