Optimization of Microwave Hyperthermia Applicator System for Deep Placed Tumors Treatment in Head and Neck Area

被引:0
|
作者
Fiser, Ondrej [1 ]
Merunka, Ilja [1 ]
Vrba, Jan [1 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Dept Electromagnet Field, Prague, Czech Republic
来源
2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS) | 2017年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this contribution is to optimize our hyperthermia applicator system intended for the tumor treatment in head and neck area. The system was redesigned to gain the focusing improved SAR and temperature distribution in large and deep seated tumors. For this purpose, two numerical phantoms: homogenous and 3D anatomical model were proposed. Three parameters were changing (applicators polarization, applicators distance between applicators and numerical model, water bolus temperature) observing their influence on reflection coefficient, SAR and temperature distribution in the treated area. For the best arrangement the SAR25 (71.3%) and T41 (94%) tumor coverage with reflection coefficient 24 dB were achieved. This is fully sufficient for the clinical utilization. The system improvement is representing a 22% increase in SAR25 parameter compared to the original proposal for superficial tumors.
引用
收藏
页码:1733 / 1738
页数:6
相关论文
共 50 条
  • [41] HEATING-SYSTEM WITH A LENS APPLICATOR FOR 430 MHZ MICROWAVE HYPERTHERMIA
    NIKAWA, Y
    KIKUCHI, M
    TERAKAWA, T
    MATSUDA, T
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1990, 6 (03) : 671 - 684
  • [42] Efficient focusing of microwave hyperthermia for small deep-seated breast tumors treatment using particle swarm optimization
    Elkayal, Heba Abdelhamid
    Ismail, Nour Eldin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (09) : 985 - 994
  • [43] MICROWAVE-HEATING SYSTEM USING LENS APPLICATOR FOR LOCALIZED HYPERTHERMIA
    NIKAWA, Y
    TAKAHASHI, Y
    WATANABE, H
    MORI, S
    KIKUCHI, M
    MICROWAVE JOURNAL, 1985, 28 (05) : 66 - 66
  • [44] THE CLINICAL USE OF INTRACAVITARY ANTENNAE IN THE TREATMENT OF DEEP SEATED TUMORS WITH MICROWAVE INDUCED HYPERTHERMIA
    BICHER, HI
    SANDHU, TS
    HETZEL, FW
    MATVIAS, F
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (10): : 1388 - 1388
  • [45] Development of ferrite core applicator system for deep-induction hyperthermia
    Kotsuka, Y
    Hankui, E
    Shigematsu, Y
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) : 1803 - 1810
  • [46] DEVELOPMENT OF A MICROWAVE PHASED-ARRAY SYSTEM FOR HYPERTHERMIA TREATMENT OF THORACIC TUMORS
    CONWAY, J
    CUDD, PA
    ANDERSON, AP
    CLINICAL RADIOLOGY, 1987, 38 (03) : 332 - 332
  • [47] A new microwave applicator with integrated cooling system for intracavitary hyperthermia of vaginal carcinoma
    Roos, D
    Seegenschmiedt, MH
    Klautke, G
    Erb, J
    Sorbe, B
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1996, 12 (06) : 743 - 756
  • [48] Primary treatment of head and neck tumors
    Dietz, A.
    Knoedler, M.
    Lordick, F.
    ONKOLOGE, 2014, 20 (02): : 144 - 151
  • [49] TREATMENT OF RECURRENT TUMORS OF HEAD AND NECK
    LORE, JM
    LARYNGOSCOPE, 1968, 78 (09): : 1445 - &
  • [50] OPTIMIZATION OF UNCOMPLICATED CONTROL FOR HEAD AND NECK TUMORS
    AGREN, A
    BRAHME, A
    TURESSON, I
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04): : 1077 - 1085