Different collector types for sampling deposition of polycyclic aromatic hydrocarbons - comparison of measurement results and their uncertainty

被引:7
|
作者
Gladtke, Dieter [1 ]
Bakker, Frits [2 ]
Biaudet, Hugues [3 ]
Brennfleck, Alexandra [4 ]
Coleman, Peter [5 ]
Creutznacher, Harald [4 ]
Van Egmond, Ben F. [2 ]
Hafkenscheid, Theo [6 ]
Hahne, Frank [7 ]
Houtzager, Marc M. [6 ]
Leoz-Garziandia, Eva [3 ]
Menichini, Edoardo [8 ]
Olschewski, Anja [1 ]
Remesch, Thomas [9 ]
机构
[1] Landesamt Nat, Umwelt & Verbraucherschutz Nordrhein Westfalen, D-45133 Essen, Germany
[2] ECN Energieonderzoek Ctr Nederland Engn & Serv, NL-1755 ZG Petten, Netherlands
[3] INERIS, F-60550 Verneuil En Halatte, France
[4] LUBW Landesanstalt Umwelt, D-76135 Karlsruhe, Germany
[5] Dept Environm Food & Rural Affairs, Sci & Evidence Team, Atmosphere & Local Environm Programme, London SW10 2AL, England
[6] TNO Environm & Geosci, NL-7300 AH Apeldoorn, Netherlands
[7] Landesamt Umweltschutz Sachsen Anhalt, D-06009 Halle, Germany
[8] Ist Super Sanita, Dipartimento Ambiente & Connessa Prevenz Primaria, I-00161 Rome, Italy
[9] UBA Umweltbundesamt GmbH Umweltanalyt Umweltwirks, A-1090 Vienna, Austria
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2012年 / 14卷 / 08期
关键词
ATMOSPHERIC DEPOSITION; PAHS; DEGRADATION; DENUDER;
D O I
10.1039/c2em30119a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different collector types, sample workup procedures and analysis methods to measure the deposition of polycyclic aromatic hydrocarbons (PAH) were tested and compared. Whilst sample workup and analysis methods did not influence the results of PAH deposition measurements, using different collector types changed the measured deposition rates of PAH significantly. The results obtained with a funnel-bottle collector showed the highest deposition rates and a low measurement uncertainty. The deposition rates obtained with the wet-only collectors were the lowest at industrial sites and under dry weather conditions. For the open-jar collectors the measurement uncertainty was high. Only at an industrial site with extremely high PAH deposition rates the results of open-jar collectors were comparable to those obtained with funnel-bottle collectors. Thus, if bulk deposition of PAH has to be measured, funnel-bottle combinations are proved to be the collectors of choice. These collectors were the only ones always fulfilling the requirements of European legislation.
引用
收藏
页码:2054 / 2062
页数:9
相关论文
共 50 条
  • [1] Measurement of Dry Deposition of Polycyclic Aromatic Hydrocarbons in Jeonju
    Kim, Hyoung Seop
    Kim, Jong-Guk
    Ghim, Young Sung
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2007, 23 (02) : 242 - 249
  • [2] RESIDUES OF POLYCYCLIC AROMATIC HYDROCARBONS IN DIFFERENT TYPES OF COFFEE
    Stanciu, Gabriela
    Birghila, Semaghiul
    Dobrinas, Simona
    SCIENTIFIC STUDY AND RESEARCH-CHEMISTRY AND CHEMICAL ENGINEERING BIOTECHNOLOGY FOOD INDUSTRY, 2008, 9 (03): : 325 - 330
  • [3] Polycyclic aromatic hydrocarbons in meat smoked with different types of wood
    Stumpe-Viksna, Ilze
    Bartkevics, Vadims
    Kukare, Agnese
    Morozovs, Andris
    FOOD CHEMISTRY, 2008, 110 (03) : 794 - 797
  • [4] Detection of polycyclic aromatic hydrocarbons in different types of processed foods
    Kumosani, Taha A.
    Moselhy, Said S.
    Asseri, Abdullah M.
    Asseri, Amer Hamzah
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2013, 29 (03) : 300 - 304
  • [5] Polycyclic aromatic hydrocarbons (PAH) in different forest humus types
    Pichler, M
    Guggenberger, G
    Hartmann, R
    Zech, W
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 1996, 3 (01) : 24 - 31
  • [6] Behavior of polycyclic aromatic hydrocarbons from different types of coals
    Zhao, ZB
    Fant, M
    Liu, KL
    Pan, WP
    Riley, JT
    Xie, KC
    PROSPECTS FOR COAL SCIENCE IN THE 21ST CENTURY, 1999, : 1417 - 1420
  • [7] Sampling precautions for the measurement of nitrated polycyclic aromatic hydrocarbons in ambient air
    Albinet, A.
    Leoz-Garziandia, E.
    Budzinski, H.
    Villenave, E.
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (23) : 4988 - 4994
  • [8] Comparison of polycyclic aromatic hydrocarbons in sediments from the Songhuajiang River (China) during different sampling seasons
    Guo, Wei
    He, Mengchang
    Yang, Zifeng
    Lin, Chunye
    Quan, Xiangchun
    Wang, Haozheng
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2007, 42 (02): : 119 - 127
  • [9] SAMPLING OF AIRBORNE POLYCYCLIC AROMATIC-HYDROCARBONS
    OTSON, R
    LEACH, JM
    CHUNG, LTK
    ANALYTICAL CHEMISTRY, 1987, 59 (13) : 1701 - 1705
  • [10] Four Years of Active Sampling and Measurement of Atmospheric Polycyclic Aromatic Hydrocarbons and Oxygenated Polycyclic Aromatic Hydrocarbons in Dronning Maud Land, East Antarctica
    Van Overmeiren, Preben
    Demeestere, Kristof
    De Wispelaere, Patrick
    Gili, Stefania
    Mangold, Alexander
    De Causmaecker, Karen
    Mattielli, Nadine
    Delcloo, Andy
    Langenhove, Herman Van
    Walgraeve, Christophe
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (03) : 1577 - 1588