An automatic 96-well solid phase extraction and liquid chromatography-tandem mass spectrometry method for the analysis of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma

被引:54
|
作者
Shou, WZ [1 ]
Pelzer, M [1 ]
Addison, T [1 ]
Jiang, XY [1 ]
Naidong, W [1 ]
机构
[1] Covance Labs Inc, Madison, WI 53704 USA
关键词
morphine; morphine-3-glucuronide; morphine-6-glucuronide; LC-MS-MS;
D O I
10.1016/S0731-7085(01)00497-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bioanalytical method using automated sample transferring, automated solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed for morphine (MOR), and its metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in human plasma. Samples of 0.25 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe(TM) II). Automated SPE was carried out on a 96-channel programmable liquid handling workstation (Quadra(TM) 96) using a C-18 sorbent. The extract was injected onto a silica column using an aqueous-organic mobile phase. The chromatographic run time was 3.5 min per injection, with retention times of 1.5, 2.0 and 2.6 min for MOR, M6G, and M3G, respectively. The detection was by monitoring MOR at m/z 286 --> 152, M6G and M3G at m/z 462 --> 286. The deuterated internal standards were monitored at m/z 289 --> 152 for MOR-d(3), and m/z 465 --> 289 for M6G-d(3) and M3G-d(3). The standard curve range was 0.5-50 ng ml(-1) for MOR, 1.0-100 ng ml(-1) for M6G, and 10-1000 ng ml(-1) for M3G. The inter-day precision and accuracy of the quality control samples were <8% relative standard deviation (RSD) and <7% relative error (RE) for MOR, <5% RSD and <2% RE for M6G, and <2% RSD and <4% RE for M3G. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 50 条
  • [21] Plasma concentrations of morphine, morphine-6-glucuronide and morphine-3-glucuronide and their relationship with analgesia and side effects in patients with cancer-related pain
    Quigley, C
    Joel, S
    Patel, N
    Baksh, A
    Slevin, M
    PALLIATIVE MEDICINE, 2003, 17 (02) : 185 - 190
  • [22] Pharmacokinetic modelling of morphine, morphine-3-glucuronide and morphine-6-glucuronide in plasma and cerebrospinal fluid of neurosurgical patients after short-term infusion of morphine
    Meineke, I
    Freudenthaler, S
    Hofmann, U
    Schaeffeler, E
    Mikus, G
    Schwab, M
    Prange, HW
    Gleiter, CH
    Brockmöller, J
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2002, 54 (06) : 592 - 603
  • [23] Cerebrospinal fluid and plasma concentrations of morphine, morphine-3-glucuronide, and morphine-6-glucuronide in patients before and after initiation of intracerebroventricular morphine for cancer pain management
    Smith, MT
    Wright, AWE
    Williams, BE
    Stuart, G
    Cramond, T
    ANESTHESIA AND ANALGESIA, 1999, 88 (01): : 109 - 116
  • [24] Determination of morphine and morphine glucuronides in human plasma by 96-well plate solid-phase extraction and liquid chromatography-electrospray ionization mass spectrometry
    Whittington, D
    Kharasch, ED
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01): : 95 - 103
  • [25] Development and validation of an LC-MS/MS method for quantifying diamorphine and its major metabolites 6-monoacetylmorphine, morphine, morphine-3-glucuronide, and morphine-6-glucuronide in human plasma
    Thomann, Jan
    Vogt, Severin B.
    Guessoum, Adrian
    Meyer, Maximilian
    Vogel, Marc
    Liechti, Matthias E.
    Luethi, Dino
    Duthaler, Urs
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1237
  • [26] MORPHINE, MORPHINE-6-GLUCURONIDE AND MORPHINE-3-GLUCURONIDE CONCENTRATIONS IN PLASMA AND CEREBROSPINAL-FLUID DURING LONG-TERM HIGH-DOSE INTRATHECAL MORPHINE ADMINISTRATION
    BIGLER, D
    CHRISTENSEN, CB
    ERIKSEN, J
    JENSEN, NH
    PAIN, 1990, 41 (01) : 15 - 18
  • [27] The development of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of morphine, morphine-3-β-glucuronide, morphine-6-β-glucuronide, hydromorphone, and normorphine in serum
    Sartori, David
    Lewis, Tamorah
    Breaud, Autumn
    Clarke, William
    CLINICAL BIOCHEMISTRY, 2015, 48 (18) : 1283 - 1290
  • [28] Quantification of midazolam, morphine and metabolites in plasma using 96-well solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    Ahsman, Maurice J.
    van der Nagel, Bart C.
    Mathot, Ron A.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 969 - 976
  • [29] PLASMA-CONCENTRATIONS OF MORPHINE, MORPHINE-3-GLUCURONIDE, AND MORPHINE-6-GLUCURONIDE AFTER INTRAVENOUS AND ORAL-ADMINISTRATION TO HEALTHY-VOLUNTEERS - RELATIONSHIP TO NONANALGESIC ACTIONS
    WESTERLING, D
    PERSSON, C
    HOGLUND, P
    THERAPEUTIC DRUG MONITORING, 1995, 17 (03) : 287 - 301
  • [30] Development and validation of a UPLC-MS/MS method with a broad linear dynamic range for the quantification of morphine, morphine-3-glucuronide and morphine-6-glucuronide in mouse plasma and tissue homogenates
    Heydari, P.
    Martins, M. L. F.
    Rosing, H.
    Hillebrand, M. J. X.
    Gebretensae, A.
    Schinkel, A. H.
    Beijnen, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1166