Mid-term results of ReCap/Magnum/Taperloc metal-on-metal total hip arthroplasty with mean follow-up of 7.1 years

被引:3
|
作者
Koutalos, Antonios A. [1 ]
Kourtis, Aristotelis [1 ]
Clarke, Ian C. [2 ]
Smith, Evert J. [1 ]
机构
[1] Southmead Hosp, Avon Orthopaed Ctr, Southmead Rd, Bristol BS10 5NB, Avon, England
[2] Loma Linda Univ, Med Ctr, Dept Orthopaed, Loma Linda, CA USA
关键词
Chrome; Cobalt; Margin-of-safety; MARS MRI; Metal-on-metal; Pseudotumour; ARTICULAR SURFACE REPLACEMENT; ION LEVELS; RESURFACING ARTHROPLASTY; ACETABULAR COMPONENT; FAILURE; WEAR; DISLOCATION; RELIABILITY; PERFORMANCE; BEARINGS;
D O I
10.5301/hipint.5000454
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Despite enthusiasm for metal-on-metal bearings, disappointing short-to mid-term outcomes has all but halted the use of this bearing articulation. This review presents mid-term results for the ReCap Magnum total hip replacement. Patients and methods: This prospective study evaluated 79 ReCap/Magnum/Taperloc total hip replacements with mean follow-up of 7.1 (range 3.7-9.2) years. 43 were female and 36 male. Metal ions were measured and radiographic measurement included a 'margin of safety' angle to quantify risk of edge loading. When a clinical suspicion of adverse reaction to metal debris was present, patients had metal artefact reduction sequence MRI. Harris Hip Score and Oxford Hip Score evaluated functional outcome and SF-12 and EQ-5L-5D assessed quality of life at final follow-up. Results: 7 hips were revised indicating 91.1% survivorship at 7.1 years. Postoperative Harris Hip Score and Oxford Hip Score significantly improved. Females and symptomatic patients predicted increased metal ions. Margin of safety correlated with postoperative Oxford Hip Score. Symptomatic hips and positive MRI showed reduced survivorship. Conclusions: Compared to more traditional bearings like metal or ceramic on polyethylene the overall outcome of this ReCap/Magnum/Taperloc study cohort is modest. It is felt that further failures will occur in this group therefore cautious interpretation of the results is justified given the potential for reduced survival outcomes.
引用
收藏
页码:226 / 234
页数:9
相关论文
共 50 条
  • [31] Metallosis after contemporary metal-on-metal total hip arthroplasty - Five to nine-year follow-up
    Korovessis, P.
    Petsinis, G.
    Repanti, M.
    Repantis, T.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (06): : 1183 - 1191
  • [32] Conversion of failed hemiarthroplasty to total hip arthroplasty: A short to mid-term follow-up study
    Pankaj, Amite
    Malhotra, Rajesh
    Bhan, Surya
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2008, 42 (03) : 294 - 300
  • [33] Midterm results of metasul metal-on-metal total hip arthroplasty
    Saito, Shu
    Ryu, Junnosuke
    Watanabe, Masahiko
    Ishii, Takao
    Saigo, Kaichiro
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (08): : 1105 - 1110
  • [34] The utility of repeat ultrasound imaging in the follow-up of metal-on-metal hip arthroplasty patients
    Matharu, G. S.
    Janardhan, S.
    Brash, L.
    Pynsent, P. B.
    Dunlop, D. J.
    James, S. L. J.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2016, 98 (02) : 143 - 149
  • [35] MRI Findings in Patients After Small-Head Metal-on-Metal Total Hip Arthroplasty with a Minimum Follow-up of 10 Years
    Reiner, Tobias
    Do, Thuy D.
    Klotz, Matthias C.
    Hertzsch, Fabian
    Seelmann, Kirsten
    Gaida, Matthias M.
    Weber, Marc-Andre
    Gotterbarm, Tobias
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (18): : 1540 - 1546
  • [36] Follow-up of patients with metal-on-metal hip replacements
    Carr, Andy
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2017, 358
  • [37] Metal-on-metal CoCrMo McKee-Farrar total hip arthroplasty: Characteristics from a long-term follow-up study
    Higuchi F.
    Inoue A.
    Semlitsch M.
    [J]. Archives of Orthopaedic and Trauma Surgery, 1997, 116 (3) : 121 - 124
  • [38] Metal-on-metal CoCrMo McKee-Farrar total hip arthroplasty: Characteristics from a long-term follow-up study
    Higuchi, F
    Inoue, A
    Semlitsch, M
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (03) : 121 - 124
  • [39] Long-Term Outcome of Small Head Metal-On-Metal Total Hip Arthroplasty: A 15-to-22 Year Follow-Up
    Maliarov, Anton
    Huk, Olga L.
    Epure, Laura M.
    Bergeron, Stephane G.
    Antoniou, John
    Zukor, David J.
    [J]. JOURNAL OF ARTHROPLASTY, 2021, 36 (09): : 3214 - 3220
  • [40] Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty
    Mokka, Jari
    Junnila, Mika
    Seppanen, Matti
    Virolainen, Petri
    Polonen, Tuukka
    Vahlberg, Tero
    Mattila, Kimmo
    Tuominen, Esa K. J.
    Rantakokko, Juho
    Aarimaa, Ville
    Kukkonen, Juha
    Makela, Keijo T.
    [J]. ACTA ORTHOPAEDICA, 2013, 84 (06) : 549 - 554