Transmission Line Design for Individual Partial Discharge Waveshape Measurement

被引:0
|
作者
Chalaki, Mojtaba Rostaghi [1 ]
Yousefpour, Kamran [1 ]
Ahmed, Zeeshan [1 ]
Park, Chanyeop [1 ]
机构
[1] Mississippi State Univ, Dept Elect & Comp Engn, Mississippi State, MS 39762 USA
关键词
Partial discharge; transmission line; frequency response; COMSOL multiphysics; transient measurement;
D O I
10.1109/eic47619.2020.9158721
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurement of transient phenomenon such as individual PD pulses requires fast, accurate, and noise-free circuits. The bandwidth of elements used in these circuits can affect the captured PD pulse waveshapes. Transmission lines, which couple the PD sources to data recording devices, are one the most important elements among various components in measurement systems. Therefore, transmission lines with wide bandwidths are necessary in building testbeds that capture individual PD pulses. This paper explains the requirements of an ideal Transmission line design that enables accurate individual PD pulse waveshape measurements. We comprehensively use finite element analysis (FEA) simulation to analyze the impact of PD testbed design on the PD pulse measurement performance. Based on the newly designed testbed with the proposed transmission line design, individual PD measurement performance is examined by the time-domain analysis of the FEA simulation. The results show the effect of transmission line parameters on its frequency responses. Also, the application of a narrow bandwidth transmission line for PD pulse measurement has been confirmed to deform its waveshape. Furthermore, the time-domain results confirmed the impact of transmission lines reflection and losses on captured waveshapes.
引用
下载
收藏
页码:554 / 557
页数:4
相关论文
共 50 条
  • [41] On-site measurement for the development of on-line partial discharge monitoring system in GIS
    Masaki, K.
    Sakakibara, T.
    Murase, H.
    Akazaki, M.
    Uehara, K.
    Menju, S.
    IEEE Transactions on Power Delivery, 1994, 9 (02): : 805 - 810
  • [42] Failure Risk of UHV AC Transmission Line Considering the Statistical Characteristics of Switching Overvoltage Waveshape
    Li, Yang
    He, Jinliang
    Yuan, Jun
    Li, Chen
    Hu, Jun
    Zeng, Rong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1731 - 1739
  • [43] Partial discharge localization in transformer windings using multi-conductor transmission line model
    Jafari, Ali Mazhab
    Akbari, Asghar
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (06) : 1028 - 1037
  • [44] Analysis of Discharge of Transmission Line in Sandstorm
    Gao Qiang
    Shi Yaohu
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 708 - 711
  • [45] A COMMENTARY ON PARTIAL DISCHARGE MEASUREMENT AND DETECTION
    BARTNIKAS, R
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (05): : 629 - 652
  • [46] Online measurement of transformer partial discharge
    Wang Baobao
    Yang Yang
    CIS WORKSHOPS 2007: INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND SECURITY WORKSHOPS, 2007, : 906 - +
  • [47] SIGNAL PROCESSING IN PARTIAL DISCHARGE MEASUREMENT
    Vedral, Josef
    Kriz, Martin
    METROLOGY AND MEASUREMENT SYSTEMS, 2010, 17 (01) : 55 - 63
  • [48] Partial Discharge Apparent Charge Measurement
    Mraz, Petr
    Mentlik, Vaclav
    Pihera, Josef
    PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 409 - 412
  • [49] Measurement and analysis of partial discharge in switchgear
    Kane, C
    Blokhintsev, I
    Golubev, A
    Proceedings: Electrical Insulation Conference and Electrical Manufacturing Conference, 2005, : 203 - 210
  • [50] Partial discharge measurement and analysis in PPIs
    Fu, Pengyu
    Zhao, Zhibin
    Li, Xuebao
    Cui, Xiang
    Wen, Teng
    Yang, Zhuodong
    Mo, Shenyang
    Zhang, Peng
    IET POWER ELECTRONICS, 2019, 12 (01) : 138 - 146