Design and testing of aptamer-based electrochemical biosensors for proteins and small molecules

被引:126
|
作者
Cheng, Alan K. H. [1 ]
Sen, Dipankar [1 ,2 ]
Yu, Hua-Zhong [1 ,2 ]
机构
[1] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Dept Mol Biol & Biochem, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Aptamer; Biosensor; Electrochemistry; Protein; DNA/RNA; DNA-MODIFIED SURFACES; LABEL-FREE; ELECTRON-TRANSFER; NUCLEIC-ACID; CATIONIC POLYTHIOPHENE; SENSITIVE DETECTION; SENSORS; RECOGNITION; BINDING; QUANTITATION;
D O I
10.1016/j.bioelechem.2009.04.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The fabrication of aptamer-based electrochemical biosensors as an emerging technology has made the detection of small and macromolecular analytes easier, faster, and more suited for the ongoing transition from fundamental analytical science to the early detection of protein biomarkers. Aptamers are synthetic oligonucleotides that have undergone iterative rounds of in vitro selection for binding with high affinity to specific analytes of choice; a sensitive yet simple method to utilize aptamers as recognition entities for the development of biosensors is to transduce the signal electrochemically. In this review article, we attempt to summarize the state-of-the-art research progresses that have been published in recent years; in particular, we focus on the electrochemical biosensors that incorporate aptamers for sensing small organic molecules and proteins. Based on differences in the design of the DNA/RNA-modified electrodes, we classify aptamer-based electrochemical sensors into three categories, for which the analyte detection relies on: (a) configurational change, i.e.. the analyte binding induces either an assembly or dissociation of the sensor construct: (b) conformational change. i.e., the analyte binding induces an alteration in the conformation (folding) of the surface immobilized aptamer strands: and (c) conductivity change, i.e., the analyte binding "switches on" the conductivity of the surface-bound aptamer-DNA constructs. In each section, we will discuss the performance of these novel biosensors with representative examples reported in recent literature. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] Rational design and performance testing of aptamer-based electrochemical biosensors for adenosine
    Chakraborty, Banani
    Jiang, Zhifeng
    Li, Yunchao
    Yu, Hua-Zhong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 635 (02) : 75 - 82
  • [2] Electrochemical aptamer-based biosensors
    Kim, Yeon Seok
    Lee, Su Jin
    Gu, Man Bock
    BIOCHIP JOURNAL, 2008, 2 (03) : 175 - 182
  • [3] Aptamer-Based Electrochemical Biosensors
    Lei Lihong
    Fu Yingchun
    Xu Xiahong
    Xie Qingji
    Yao Shouzhuo
    PROGRESS IN CHEMISTRY, 2009, 21 (04) : 724 - 731
  • [4] Design Strategies for Aptamer-Based Biosensors
    Han, Kun
    Liang, Zhiqiang
    Zhou, Nandi
    SENSORS, 2010, 10 (05): : 4541 - 4557
  • [5] New trends in aptamer-based electrochemical biosensors
    Velasco-Garcia, Maria N.
    Missailidis, Sotiris
    GENE THERAPY AND MOLECULAR BIOLOGY, 2009, 13 (01): : 1 - 9
  • [6] Aptamer-based biosensors
    Song, Shiping
    Wang, Lihua
    Li, Jiang
    Zhao, Jianlong
    Fan, Chunhai
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (02) : 108 - 117
  • [8] AN APTAMER-BASED SENSOR FOR SMALL MOLECULES
    不详
    CHEMICAL & ENGINEERING NEWS, 2009, 87 (11) : 49 - 49
  • [9] Electrochemical Aptamer-Based Biosensors for the Detection of Cardiac Biomarkers
    Grabowska, Iwona
    Sharma, Neha
    Vasilescu, Alina
    Iancu, Madalina
    Badea, Gabriela
    Boukherroub, Rabah
    Ogale, Satishchandra
    Szunerits, Sabine
    ACS OMEGA, 2018, 3 (09): : 12010 - 12018
  • [10] Confounding effects on the response of electrochemical aptamer-based biosensors
    Fontaine, Nicolas
    Dauphin-Ducharme, Philippe
    CURRENT OPINION IN ELECTROCHEMISTRY, 2023, 41