Evaluation of seismic torsional response of ductile RC buildings with soft first story

被引:20
|
作者
Hareen, Ch B., V [1 ]
Mohan, S. C. [1 ]
机构
[1] BITS Pilani, Dept Civil Engn, Hyderabad Campus, Hyderabad 500078, Telangana, India
关键词
Bi-directional ground motion; Masonry infill walls; Nonlinear analysis; Plan asymmetric building; Soft first story; Torsional response; CONCRETE STRENGTH VARIABILITY; ASYMMETRIC BUILDINGS; FRAME; BEHAVIOR; ECCENTRICITY; PERFORMANCE; BALANCE; DESIGN; STIFF;
D O I
10.1016/j.istruc.2020.12.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the inelastic torsional response of plan asymmetric ductile RC buildings with a soft first story. The buildings of Rectangular, L, T, and U plan shapes are considered for the study. Force-based fiber beam column elements are modeled for the inelastic response prediction of the buildings. Masonry infill walls are uniformly distributed in the plan and considered for the evaluation of torsional response. The pushover methods, Extended N2 and Extended Capacity Spectrum Method - FEMA 440 are adopted to estimate the inelastic torsional response. Bi-directional nonlinear time history analysis is carried out on the buildings considering near field and far-field ground motions. Story drift ratio and curvature demand-capacity (D/C) ratio of columns are reported at the stiff, flexible side of buildings. The torsional response of infill wall buildings is compared with that of bare frame buildings. It was observed that the torsionally irregular ductile buildings with soft first story exhibit higher seismic demand on the flexible side corner columns. Infill wall interaction amplifies the torsional response at the bottom story, causing an increase in displacements higher at the flexible side and moderate near the stiff side. This study concludes that the flexible side corner column in plan asymmetric building with a soft first story can be conservatively designed for 1.5 times the design forces obtained from the analysis. This conservative design ensures stable energy dissipation in the corner column under load reversals, without significant strength reduction under higher excitation levels. The designer shall properly distribute lateral load resisting elements in a plan to prevent premature failure of the columns located internally and close to the initial center of rigidity. The designer can avoid the collapse of columns located internally in the buildings with stiff peripheral frames by designing for forces 1.5 times higher than obtained.
引用
收藏
页码:1640 / 1654
页数:15
相关论文
共 50 条
  • [31] Inelastic response of RC frame buildings with seismic isolation
    Cardone, Donatello
    Flora, Amedeo
    Gesualdi, Giuseppe
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (06): : 871 - 889
  • [32] Seismic response of irregular RC buildings designed for gravity and seismic loads
    Blasi, Gianni
    Scarlino, Andrea Santo
    Chirivi, Salvatore
    Perrone, Daniele
    Aiello, Maria Antonietta
    BULLETIN OF EARTHQUAKE ENGINEERING, 2024, 22 (10) : 5231 - 5257
  • [33] Seismic response of current RC buildings in Kathmandu Valley
    Chaulagain, Hemchandra
    Rodrigues, Hugo
    Spacone, Enrico
    Varum, Humberto
    STRUCTURAL ENGINEERING AND MECHANICS, 2015, 53 (04) : 791 - 818
  • [34] Response reduction factor R evaluation for soft story reinforced concrete buildings
    Cerda, Pedro
    Rivero, Pedro
    Lobo-Quintero, William
    CIENCIA E INGENIERIA, 2006, 27 (02): : 69 - 77
  • [35] Seismic performance assessment of multi-story RC buildings with soft-story collapse mechanism equipped with gapped inclined bracing (GIB)
    Shahsahebi, Amir
    Waezi, Zakariya
    Hashemi, M. Javad
    STRUCTURES, 2020, 28 : 2448 - 2466
  • [36] Strength of Beam-column Joint in Soft First Story of RC Buildings Part 2: Design Equations
    Halim, Sefatullah
    Takahashi, Susumu
    Ichinose, Toshikatsu
    Teshigawara, Masaomi
    Kamiya, Takashi
    Fukuyama, Hiroshi
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2014, 12 (05) : 146 - 157
  • [37] Torsional irregularity indices for the seismic demand assessment of RC moment resisting frame buildings
    Bhasker, Rohan
    Arun, Menon
    STRUCTURES, 2020, 26 : 888 - 900
  • [38] Seismic evaluation and reliability index of soft story buildings on flexible soils by using old and current seismic regulations in Mexico
    Jara, J. M.
    Florio, E.
    Olmos, B. A.
    ENGINEERING STRUCTURES, 2023, 286
  • [39] Seismic collapse propagation in 6-story RC regular and irregular buildings
    Karimiyan, Somayyeh
    Moghadam, Abdolreza S.
    Karimiyan, Morteza
    Kashan, Ali Husseinzadeh
    EARTHQUAKES AND STRUCTURES, 2013, 5 (06) : 753 - 779
  • [40] Probabilistic seismic performance evaluation of non-seismic RC frame buildings
    Maniyar, M. M.
    Khare, R. K.
    Dhakal, R. P.
    STRUCTURAL ENGINEERING AND MECHANICS, 2009, 33 (06) : 725 - 745