The XFP (17-BM) beamline for X-ray footprinting at NSLS-II

被引:16
|
作者
Asuru, Awuri [1 ,2 ]
Farquhar, Erik R. [1 ]
Sullivan, Michael [1 ]
Abel, Donald [1 ]
Toomey, John [1 ]
Chance, Mark R. [1 ]
Bohon, Jen [1 ]
机构
[1] Case Western Reserve Univ, Dept Nutr, Ctr Synchrotron Biosci, 10900 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Syst Biol Grad Program, Med Scientist Training Program, 10900 Euclid Ave, Cleveland, OH 44106 USA
基金
美国国家科学基金会;
关键词
footprinting; structural dynamics; beamline; solution state; MASS-SPECTROMETRY; ACTIVATION; RADIOLYSIS; PROTEINS; DYNAMICS; PROBES;
D O I
10.1107/S1600577519003576
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hydroxyl-radical mediated synchrotron X-ray footprinting (XF) is a powerful solution-state technique in structural biology for the study of macromolecular structure and dynamics of proteins and nucleic acids, with several synchrotron resources available to serve the XF community worldwide. The XFP (Biological X-ray Footprinting) beamline at the NSLS-II was constructed on a three-pole wiggler source at 17-BM to serve as the premier beamline for performing this technique, providing an unparalleled combination of high flux density broadband beam, flexibility in beam morphology, and sample handling capabilities specifically designed for XF experiments. The details of beamline design, beam measurements, and science commissioning results for a standard protein using the two distinct XFP endstations are presented here. XFP took first light in 2016 and is now available for general user operations through peer-reviewed proposals. Currently, beam sizes from 450 mu m x 120 mu m to 2.7mm x 2.7mm (FWHM) are available, with a flux of 1.6 x 10(16)photonss(-1) (measured at 325mA ring current) in a broadband (similar to 5-16keV) beam. This flux is expected to rise to 2.5 x 10(16)photonss(-1) at the full NSLS-II design current of 500mA, providing an incident power density of >500Wmm(-2) at full focus.
引用
收藏
页码:1388 / 1399
页数:12
相关论文
共 50 条
  • [41] NSLS-II Biomedical Beamlines for Macromolecular Crystallography, FMX and AMX, and for X-ray Scattering, LIX: Current Developments
    Fuchs, M. R.
    Sweet, R. M.
    Berman, L. E.
    Hendrickson, W. A.
    Chubar, O.
    Canestrari, N.
    Idir, M.
    Yang, L.
    Schneider, D. K.
    [J]. 17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [42] NSLS X-19A BEAMLINE PERFORMANCE FOR X-RAY ABSORPTION-MEASUREMENTS
    YANG, CY
    PENNERHAHN, JE
    STEFAN, PM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 157 - 161
  • [43] X-ray spectromicroscopy of polymers and tribological surfaces at beamline X1A at the NSLS
    Ade, H
    Smith, AP
    Zhang, H
    Zhuang, GR
    Kirz, J
    Rightor, E
    Hitchcock, A
    [J]. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1997, 84 (1-3) : 53 - 71
  • [44] Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector
    Ilinski, P.
    [J]. 11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [45] Optimization of NSLS-II blade X-ray beam position monitors: From photoemission type to diamond detector
    Ilinski, P.
    [J]. IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference, 2013, : 67 - 70
  • [46] Soft Matter Interfaces beamline at NSLS-II: geometrical ray-tracing vs. wavefront propagation simulations
    Zhernenkov, Mikhail
    Canestrari, Niccolo
    Chubar, Oleg
    DiMasi, Elaine
    [J]. ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [47] Initial Performances of First Undulator-Based Hard X-Ray Beamlines of NSLS-II Compared to Simulations
    Chubar, Oleg
    Chu, Yong S.
    Huang, Xiaojing
    Kalbfleisch, Sebastian
    Yan, Hanfei
    Shaftan, Timur
    Wang, Guimei
    Cai, Yong Q.
    Suvorov, Alexey
    Fluerasu, Andrei
    Wiegart, Lutz
    Chen-Wiegart, Yu-chen Karen
    Thieme, Juergen
    Williams, Garth
    Idir, Mourad
    Tanabe, Toshiya
    Zschack, Paul
    Shen, Qun
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [48] BEAMLINE X-11A AT THE NSLS - A UNIQUE FACILITY FOR X-RAY ABSORPTION-SPECTROSCOPY
    HEALD, SM
    SAYERS, DE
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1932 - 1935
  • [49] New Optical Design and Performance of the NSLS X21 X-ray Wiggler Beamline
    Berman, Lonny E.
    Caliebe, W. A.
    Montanez, P. A.
    Yang, L.
    Nelson, C. S.
    Lenhard, A.
    Staicu, F. A.
    Stelmach, C.
    LaMarra, S. C.
    Pjerov, S.
    Hulbert, S. L.
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C138 - C138
  • [50] Illumination for coherent soft X-ray applications: the new X1A beamline at the NSLS
    Winn, B
    Ade, H
    Buckley, C
    Feser, M
    Howells, M
    Hulbert, S
    Jacobsen, C
    Kaznacheyev, K
    Kirz, J
    Osanna, A
    Maser, J
    McNulty, I
    Miao, J
    Oversluizen, T
    Spector, S
    Sullivan, B
    Wang, Y
    Wirick, S
    Zhang, H
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (06): : 395 - 404