Does Landmark Selection Affect the Reliability of Tibial Tubercle-Trochlear Groove Measurements Using MRI?

被引:50
|
作者
Wilcox, Jason J. [1 ]
Snow, Brian J. [2 ]
Aoki, Stephen K. [3 ]
Hung, Man [3 ]
Burks, Robert T. [3 ]
机构
[1] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
[2] Snow Orthopaed, Mckinney, TX USA
[3] Univ Utah, Dept Orthopaed, Salt Lake City, UT USA
关键词
PATELLAR INSTABILITY; PATELLOFEMORAL MALALIGNMENT; NATURAL-HISTORY; CT-SCAN; TUBEROSITY; DISTANCE; DISLOCATIONS; REALIGNMENT; RADIOGRAPHY; DYSPLASIA;
D O I
10.1007/s11999-012-2269-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A lateralized tibial tubercle is one potential cause of patellar instability. The tibial tubercle-trochlear groove (TT-TG) distance using CT is a reliable measure and considered the gold standard. Using MRI for this purpose has increased, although the reliability of doing so is not well studied. We sought to (1) determine variability in the insertion of the patellar tendon relative to the tibial tubercle and whether this affects the measurement on MRI of the traditional TT-TG distance versus the functional patellar tendon-trochlear groove (PT-TG) distance, (2) determine the reliability of measuring the osseous TT-TG distance, (3) determine the reliability of measuring the soft tissue PT-TG distance, and (4) compare the reliabilities of using osseous (TT-TG) versus soft tissue (PT-TG) landmarks. Four observers measured the TT-TG and the PT-TG distances of 50 MR images of knees obtained for any reason. Each observer repeated these measurements 30 days later. The interobserver and intraobserver reliabilities, measurements per observer that varied from the group mean by greater than 2 mm, and the limit of agreement were calculated. The TT-TG and PT-TG differed by as little as 0.11 mm and by as much as 4.18 mm with an average difference of 1.37 mm. The interobserver and intraobserver reliabilities were greater than 90% for the PT-TG and TT-TG distances. The PT-TG distance was less variable in that this measurement showed interobserver and intraobserver reliabilities of 0.977 and 0.972 respectively, versus 0.913 and 0.961 for the TT-TG measurement. Additionally, the PT-TG measurements resulted in a lower average difference to the mean for each observer, less number of knees per observer where the difference to the mean was greater than 2 mm, and improved limit of agreement. The TT-TG and the PT-TG distances were not identical and differed by as much as 4.18 mm; as such they are not interchangeable when measuring this distance. Both methods are reliable for measuring lateral offset of the extensor mechanism, but the use of soft tissue landmarks is less variable and thus would provide a more reliable measurement for surgical planning. Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:2253 / 2260
页数:8
相关论文
共 50 条
  • [21] Axial Scan Orientation and the Tibial Tubercle-Trochlear Groove Distance: Error Analysis and Correction
    Yao, Lawrence
    Gai, Neville
    Boutin, Robert D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (06) : 1291 - 1296
  • [22] Femoral Anteversion Is Related to Tibial Tubercle-Trochlear Groove Distance in Patients with Patellar Dislocation
    Xu, Zijie
    Zhang, Hua
    Chen, Jiaxing
    Mohamed, Sheikh Ibrahimrashid
    Zhou, Aiguo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (04): : 1114 - 1120
  • [23] Femorotibial rotation is linearly associated with tibial tubercle-trochlear groove distance: A cadaveric study
    Pascual-Leone, Nicolas
    Jahandar, Amirhossein
    Davie, Ryann
    Bram, Joshua T.
    Chipman, Danielle E.
    Imhauser, Carl W.
    Green, Daniel W.
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2024, 9 (04) : 598 - 602
  • [24] Utility of the Merchant View Radiograph for Assessment of Tibial Tubercle-Trochlear Groove Distance: A Comparison to MRI in Pediatric and Adolescent Patients
    Bernholt, David L.
    Lamplot, Joseph D.
    Block, Andrew M.
    Nepple, Jeffrey J.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2021, 41 (08) : E628 - E634
  • [25] Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle-trochlear groove can be an aid
    Zhang, He
    Cao, Chengming
    Zhang, Han
    Han, Shoujiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [26] Individualizing the Tibial Tubercle-Trochlear Groove Distance: Patellar Instability Ratios That Predict Recurrent Instability
    Camp, Christopher L.
    Heidenreich, Mark J.
    Dahm, Diane L.
    Stuart, Michael J.
    Levy, Bruce A.
    Krych, Aaron J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2016, 44 (02): : 393 - 399
  • [27] Tibial Tubercle-Trochlear Groove Distance Influences Patellar Tilt After Total Knee Arthroplasty
    Nakamura, Shinichiro
    Shima, Koichiro
    Kuriyama, Shinichi
    Nishitani, Kohei
    Ito, Hiromu
    Matsuda, Shuichi
    JOURNAL OF ARTHROPLASTY, 2019, 34 (12): : 3080 - 3087
  • [28] Evaluation of the normal tibial tubercle-trochlear groove distance with magnetic resonance imaging in a Turkish population
    Kaplanoglu, Hatice
    Turan, Aynur
    Hekimoglu, Baki
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2019, 10 (01) : 1 - 4
  • [29] Variation in Tibial Tubercle-Trochlear Groove Measurement as a Function of Age, Sex, Size, and Patellar Instability
    Pennock, Andrew T.
    Alam, Milad
    Bastrom, Tracey
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (02): : 389 - 393
  • [30] Q-vector measurements: physical examination versus magnetic resonance imaging measurements and their relationship with tibial tubercle-trochlear groove distance
    Graf, Kristin H.
    Tompkins, Marc A.
    Agel, Julie
    Arendt, Elizabeth A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (03) : 697 - 704