Applying Directly Modified RDFT Method in Active Power Filter for the Power Quality Improvement of the Weak Power Grid

被引:6
|
作者
Hou, Rui [1 ]
Wu, Jian [2 ]
Song, Huihui [2 ]
Qu, Yanbin [2 ]
Xu, Dianguo [2 ]
机构
[1] Qingdao Univ Technol, Sch Informat & Control Engn, Qingdao 266525, Peoples R China
[2] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
power quality; power harmonic filters; microgrid; detection algorithms; error correction; discrete Fourier transforms; FREQUENCY ESTIMATION; SOLAR-PV; SYSTEM; PHASOR; IMPLEMENTATION;
D O I
10.3390/en13184884
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The recursive discrete Fourier transformation (RDFT) method can be used for grid voltage phase-locking and harmonic current detection in a shunt active power filter (SAPF). However, in weak power grids such as microgrids, significant errors might occur in the amplitude and phase detection due to grid frequency deviation. In this study, to resolve this problem, a directly modified RDFT (DMRDFT) method is proposed for SAPF weak grid application. Through theoretical analysis, the errors of phase and amplitude detection were found to consist of fixed error and fluctuating error. The fixed error is only determined by frequency deviation, whereas the fluctuating error is also related to the recursive pointer and the initial phase. The DMRDFT algorithm can obtain the real grid frequency through the calculation of the phase angle difference for two consecutive periods. Then it can employ the grid frequency deviation and the recursive pointer value to directly correct the detection results gathered by the conventional RDFT algorithm. As a result, DMRDFT can yield accurate amplitude and phase information of the grid voltage or current with a simple calculation. Simulation results verify the high precision of the proposed DMRDFT method in both steady and dynamic situations. Experimental results show that the DMRDFT method can significantly increase the SAPF compensation performance when grid frequency shifts.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Active power filter based on wind turbine for electric power system quality improvement
    Rekik, Mouna
    Krichen, Lotfi
    [J]. 2014 11TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2014,
  • [32] Improvement of electric power quality using active power filter for systems with nonlinear loads
    Department of Electrical Engineering, Natl. Taiwan Univ. of Sci. Technol., Taipei, 106, Taiwan
    [J]. Journal of the Chinese Institute of Electrical Engineering, Transactions of the Chinese Institute of Engineers, Series E/Chung KuoTien Chi Kung Chieng Hsueh K'an, 2002, 9 (01): : 75 - 83
  • [33] Performance Evaluation of a Three Phase Shunt Active Power Filter For Power Quality Improvement
    Farooq, Anha
    Bhat, Abdul Hamid
    [J]. 2015 INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2015, : 214 - 219
  • [34] Adaptive Active Power Filter for Power Quality Improvement under Random Load Variation
    Mortazavi, S. S.
    Kianinezhad, R.
    Ghasemi, A.
    [J]. 2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2008, : 1408 - +
  • [35] A real Time Study of Hybrid series Active Power Filter for Power Quality Improvement
    Swain, Sushree Diptimayee
    Ray, Pravat Kumar
    Mohanty, Kanungo Barada
    [J]. PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [36] Power Quality Improvement Based on Shunt Active Power Filter Connected to a Photovoltaic Array
    Belaidi, Rachid
    Fathi, Mohamed
    Larafi, Mohamed Mghezzi
    Kaci, Gunia Mohand
    Belaidi, Rachid
    Haddouche, A.
    [J]. PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 557 - 562
  • [37] Improvement of power quality in EAST power supply system based on hybrid active filter
    Shen, Xianshun
    Gao, Ge
    Wu, Yanan
    Lu, Jing
    Tan, Liang
    Dai, Mingyan
    Tian, Yunxiang
    [J]. FUSION ENGINEERING AND DESIGN, 2020, 161 (161)
  • [38] Evaluation method of power grid adaptability of active power quality control equipment
    Lin, Weihan
    Sun, Jianjun
    Tang, Yuzheng
    Zhong, Peijun
    Zha, Xiaoming
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (04): : 185 - 191
  • [39] Kalman filter variant intelligent control for power quality improvement in photovoltaic active power filter system
    Prince, Satyavarta Kumar
    Panda, Kaibalya Prasad
    Panda, Gayadhar
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (03):
  • [40] A Modular Multilevel Converter-Shunt Active Power Filter-Based Hybrid Topology for Grid Power Quality Improvement
    Zemirline, Nassim
    Kabeche, Nadir
    Moulahoum, Samir
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024,