Cumulative Total Effective Whole-Body Radiation Dose in Critically Ill Patients

被引:21
|
作者
Rohner, Deborah J. [1 ]
Bennett, Suzanne [2 ]
Samaratunga, Chandrasiri [3 ]
Jewell, Elizabeth S. [4 ]
Smith, Jeffrey P. [3 ]
Gaskill-Shipley, Mary [3 ]
Lisco, Steven J. [5 ]
机构
[1] Univ Kentucky, Dept Anesthesiol, Lexington, KY 40536 USA
[2] Univ Cincinnati, Dept Anesthesiol, Cincinnati, OH USA
[3] Univ Cincinnati, Dept Radiol, Cincinnati, OH USA
[4] Univ Michigan, Dept Anesthesiol, Ann Arbor, MI 48109 USA
[5] Univ Nebraska Med Ctr, Dept Anesthesiol, Omaha, NE USA
关键词
INTENSIVE-CARE-UNIT; ROUTINE CHEST RADIOGRAPHS; COMPUTED-TOMOGRAPHY; IONIZING-RADIATION; DIAGNOSTIC-RADIOLOGY; TRAUMA PATIENTS; CANCER-RISK; CT SCANS; EXPOSURE; STATES;
D O I
10.1378/chest.12-2222
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Methods: Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Results: Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Conclusions: Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.
引用
收藏
页码:1481 / 1486
页数:6
相关论文
共 50 条
  • [41] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Inoue, Yusuke
    Ohkubo, Yu
    Nagahara, Kazunori
    Uehara, Ayuka
    Takano, Makoto
    [J]. ANNALS OF NUCLEAR MEDICINE, 2022, 36 (04) : 411 - 419
  • [42] Effects of whole-body vibration - The dose makes it
    Fritz, Martin
    [J]. ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2008, 58 (10): : 290 - 301
  • [43] Whole-body dose from tomotherapy delivery
    Mutic, S
    Low, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (01): : 229 - 232
  • [44] XENON WHOLE-BODY COUNTING AND DOSE DETERMINATIONS
    HOWARD, LE
    SOMMERS, JF
    [J]. HEALTH PHYSICS, 1980, 38 (03): : 349 - 357
  • [45] Whole-body CT-based imaging algorithm for multiple trauma patients: radiation dose and time to diagnosis
    Gordic, S.
    Alkadhi, H.
    Hodel, S.
    Simmen, H-P
    Brueesch, M.
    Frauenfelder, T.
    Wanner, G.
    Sprengel, K.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1047):
  • [46] Low-Dose Whole-Body Computed Tomography and Radiation Exposure in Patients With Trauma-Trust, but Verify
    Purcell, Laura N.
    Charles, Anthony
    [J]. JAMA SURGERY, 2020, 155 (03) : 232 - 232
  • [47] Patient-specific radiation dose for Chinese pediatric patients undergoing whole-body PET/CT examinations
    Jia, Haoran
    Xue, Mengjia
    Li, Xianru
    Zhuang, Mingzan
    Xie, Tianwu
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):
  • [48] A RETROSPECTIVE EVALUATION OF RADIATION DOSE ASSOCIATED WITH LOW DOSE FDG PROTOCOLS IN WHOLE-BODY PET/CT
    Willowson, K.
    Bailey, E.
    Bailey, D.
    [J]. INTERNAL MEDICINE JOURNAL, 2012, 42 : 4 - 4
  • [49] A retrospective evaluation of radiation dose associated with low dose FDG protocols in whole-body PET/CT
    Kathy P. Willowson
    Elizabeth A. Bailey
    Dale L. Bailey
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 49 - 53
  • [50] A retrospective evaluation of radiation dose associated with low dose FDG protocols in whole-body PET/CT
    Willowson, Kathy P.
    Bailey, Elizabeth A.
    Bailey, Dale L.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 49 - 53