A quantitative study of radionuclide characteristics for radioimmunotherapy from 3D reconstructions using serial autoradiography

被引:13
|
作者
Muthuswamy, MS
Roberson, PL
TenHaken, RK
Buchsbaum, DJ
机构
[1] UNIV MICHIGAN,DEPT RADIAT ONCOL,ANN ARBOR,MI 48109
[2] UNIV ALABAMA,DEPT RADIAT ONCOL,BIRMINGHAM,AL
关键词
dosimetry; (131)iodine-labeled monoclonal antibodies; quantitative autoradiography; radioimmunotherapy; radiolabeled antibodies; radionuclides; colon cancer;
D O I
10.1016/S0360-3016(96)85026-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Using I-131-labeled monoclonal antibody (MoAb) data, assess the dosimetrical impact of labeling the same MoAb with Re-186 or Y-90, under the assumption that the biodistribution of the radiolabeled MoAb in tumor relative to blood is independent of the radionuclide. Methods and Materials: Radial radioactivity and dose-rate distributions at 1, 4, and 7 days postinjection were derived from three dimensional (3D) reconstructions of serial autoradiographs of LS174T human colon cancer xenografts in athymic nude mice treated with a single intraperitoneal administration of 300 mu Ci I-131-labeled MoAb 17-1A. Bone marrow dose was calculated taking into account energy deposited external to the bone marrow cavity due to the range of the beta particles. Results: For 1 cm diameter tumors, uptake was mostly at the tumor surface for earlier postinjection times, but exhibited comparable activity levels from the surface to the core of the 7-day sample. The computed dose-rate distributions for Re-186 and Y-90 were more uniform than for I-131, but smaller fractions of the dose were deposited within the tumor volume due to the larger mean energies of Y-90 and Re-186 beta particles relative to those for I-131. However, when the tumor doses were normalized to the production of equivalent bone marrow doses, in the case of athymic nude mice, the tumor doses were calculated to be 15.3 Gy (I-131), 14.1 Gy (Re-186), and 12.0 Gy (Y-90). For comparison, these calculations were extended to the case of human therapy, yielding tumor doses of 16.7 Gy (I-131), 18.2 GY (Re-186), and 13.4 Gy (Y-90). Conclusion: In the case of colon cancer xenografts where the MoAb uptake is initally concentrated at the tumor surface, we find a decreasing tumor dose per constant bone marrow dose for radionuclides of increasing mean beta energies and decreasing half-lives. However, a radionuclide with larger mean beta energy such as Y-90 generates a significantly more uniform dose deposition within the tumor, especially concerning the core of the tumor, compared to I-131. For human therapy, a gamma component adds little to the tumor dose but increases dose to the marrow.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 50 条
  • [31] 3D Architecture of Ductal Carcinoma in Situ from Image Reconstructions
    Norton, Kerri-Ann
    Namazi, Sameera
    Fujibayashi, Mariko
    Ganesan, Shridar
    Barnard, Nicola
    Bhanot, Gyan
    Shinbrot, Troy
    Iyatomi, Hitoshi
    Ogawa, Koichi
    2012 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2012,
  • [32] Estimating the Coverage in 3D Reconstructions of the Colon from Colonoscopy Videos
    Muhlethaler, Emmanuelle
    Posner, Erez
    Bouhnik, Moshe
    IMAGING SYSTEMS FOR GI ENDOSCOPY, AND GRAPHS IN BIOMEDICAL IMAGE ANALYSIS, ISGIE 2022, 2022, 13754 : 56 - 65
  • [33] 3-DIMENSIONAL RECONSTRUCTIONS FROM SERIAL SECTIONS USING COMPUTER-GRAPHICS
    MURANAKA, Y
    KINO, H
    BABA, N
    KANAYA, K
    JOURNAL OF ELECTRON MICROSCOPY, 1990, 39 (04): : 286 - 286
  • [34] Anatomical study to the vessels of the lower limb by using CT scan and 3D reconstructions of the injected material
    Chen, Sheng-hua
    Chen, Mei-mei
    Xu, Da-chuan
    He, Hui
    Peng, Tian-hong
    Tan, Jian-guo
    Xiang, Yu-yan
    SURGICAL AND RADIOLOGIC ANATOMY, 2011, 33 (01) : 45 - 51
  • [35] Anatomical study to the vessels of the lower limb by using CT scan and 3D reconstructions of the injected material
    Sheng-hua Chen
    Mei-mei Chen
    Da-chuan Xu
    Hui He
    Tian-hong Peng
    Jian-guo Tan
    Yu-yan Xiang
    Surgical and Radiologic Anatomy, 2011, 33 : 45 - 51
  • [36] Shape diversity in conodont elements, a quantitative study using 3D topography
    Assemat, Alexandre
    Thiery, Ghislain
    Lieffroy, Thibaud
    Girard, Catherine
    MARINE MICROPALEONTOLOGY, 2023, 184
  • [37] Quantitative study of the 'MEMSNAS' process for 3D microfabrication using binary lithography
    Marty, F
    Didelon, S
    Mercier, B
    Moyroud, C
    Bourouina, T
    DTIP 2003: DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS 2003, 2003, : 312 - 317
  • [38] Advanced 3D image reconstruction from serial slices
    Gordon, Michael
    DeLoid, Glen
    National Computer Graphics Association, NCGA - Conference Proceedings, 1990,
  • [39] Reconstructing a 3D structure from serial histological sections
    Ourselin, S
    Roche, A
    Subsol, G
    Pennec, X
    Ayache, N
    IMAGE AND VISION COMPUTING, 2001, 19 (1-2) : 25 - 31
  • [40] Experimental justification for using 3D conductivity reconstructions in electrical impedance tomography
    Halter, Ryan J.
    Hartov, Alex
    Paulsen, Keith D.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S115 - S127