Liquid competition radioimmunoassay for the detection and quantification of the human immunodeficiency virus p24 antigen in serum

被引:0
|
作者
Tshitsh, A. Tshiband [1 ]
Ditu M. M., S. [2 ]
Kabwe, B. [3 ]
Kiampa, P. [1 ]
Bamoleke, A. [1 ]
机构
[1] Ctr Reg Etud Nucl Kinshasa, Serv Prod Trousses Radioimmunodosage, Kinshasa, DEM REP CONGO
[2] Univ Kinshasa, Fac Med, Dept Nucl Med, Kinshasa, DEM REP CONGO
[3] Clin Univ Kinshasa, Dept Anesthesie, Kinshasa, DEM REP CONGO
来源
IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE | 2007年 / 22卷 / 05期
关键词
HIV type 1 p24; Radioimmunoassay; Recombinant p24; Radio-iodination; Polyclonal antibody;
D O I
10.1016/j.immbio.2007.07.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Among the less costly viral assays that may be appropriate for resource-poor countries, the workshop steering committee (A meeting organized by the Forum for Collaborative HIV Research April 22, 2002 Washington, DC) selected the heat-denatured p24 assay for consideration at this meeting because of its advanced stage of development. Developed by Jorg Schupbach (University of Zurich), this assay for HIV p24 antigen is more sensitive than the original p24 assay used as a viral marker in early clinical trials of HIV therapies. The assay uses heat denaturation in a conventional p24 antigen Elisa assay. Boiling for 5 minutes destroys antibody and preserves antigen. Our test called phi CGEACRENK HIV-p24 RIA" is a transposition of signal-amplification-boosted of head-denatured plasma Elisa (1) to a radioimmunoassay performed with in-house reagents. The radioimmunoassay technique is based on the competitive binding of the serum HIV-1 p24 and radiolabel recombinant p24 preparation. They compete for binding to an antibody specific present in a substoichiometric amount. Complex of radiolabeled and unlabeled p24 antigen were separated from unbound species by reaction with an anti-rabbit sheep immunoglobulin as second antibody (house made). The detection limit of p24 was 0.05 pg/ml with as little as 10 ul of serum. This paper describes, for the first time, the successful production of polyclonal antisera specific for HIV-1 p24 and the radio iodination of recombinant HIV-1 p24 using exhaustive chloramin-T oxidation and the development of a sensitive radioimmunoassay (RIA) for measuring HIV-1 p24 in serum. (c) 2007 Elsevier Masson SAS. Tous droits reserves.
引用
收藏
页码:339 / 341
页数:3
相关论文
共 50 条
  • [31] LACK OF PREDICTIVE VALUE OF MATERNAL HUMAN-IMMUNODEFICIENCY-VIRUS P24 ANTIGEN FOR TRANSMISSION OF INFECTION TO THEIR CHILDREN
    PAPAEVANGELOU, V
    MOORE, T
    NAGARAJ, V
    KRASINSKI, K
    BORKOWSKY, W
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1992, 11 (10) : 851 - 855
  • [32] IMMUNE-COMPLEX P24 ANTIGEN - A NEW PROGNOSTIC MARKER IN HUMAN-IMMUNODEFICIENCY-VIRUS INFECTION
    CABEZAS, T
    QUIROS, E
    GARCIA, F
    HERNANDEZQUERO, J
    BERNAL, MC
    MARTINEZ, MA
    DELAHIGUERA, J
    PIEDROLA, G
    MAROTO, MC
    INFECTION, 1994, 22 (01) : 4 - 7
  • [33] SERUM BETA2-MICROGLOBULIN LEVELS AND P24 ANTIGEN, LYMPHOCYTE DEPLETION AND DISEASE PROGRESSION IN HUMAN-IMMUNODEFICIENCY-VIRUS INFECTION
    ALFIERI, R
    CHIRIANNI, A
    MANCINO, T
    REMONDELLI, P
    RUSSO, P
    LIUZZI, G
    DELLAMORTE, R
    STAIANO, N
    INTERNATIONAL JOURNAL OF CLINICAL & LABORATORY RESEARCH, 1992, 22 (01): : 48 - 51
  • [34] IMPROVED DETECTION OF HIV P24 ANTIGEN IN SERUM AFTER ACID PRETREATMENT
    RODRIGUEZIGLESIAS, MA
    ALVAREZ, JR
    VERGARA, A
    GARCIAVALDIVIA, MS
    JESUS, I
    MIRA, J
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1992, 11 (09) : 849 - 850
  • [35] Earlier detection of human immunodeficiency virus type 1 p24 antigen and immunoglobulin G and M antibodies to p17 antigen in seroconversion serum panels by immune complex transfer enzyme immunoassays
    Hashida, S
    Ishikawa, S
    Hashinaka, K
    Nishikata, I
    Oka, S
    Ishikawa, E
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2000, 7 (06) : 872 - 881
  • [36] APPLICATION OF A RADIOIMMUNOASSAY FOR DETECTION OF THE MAJOR INTERNAL ANTIGEN (P24) OF BOVINE LEUKEMIA-VIRUS FROM CULTURED LYMPHOCYTES OF CATTLE
    SCHMERR, MJF
    VANDERMAATEN, MJ
    MILLER, JM
    COMPARATIVE IMMUNOLOGY MICROBIOLOGY AND INFECTIOUS DISEASES, 1980, 3 (03) : 327 - 336
  • [37] A MONOCLONAL INTERNAL IMAGE ANTI-IDIOTYPE ANTIBODY TO HUMAN ANTI-HUMAN-IMMUNODEFICIENCY-VIRUS P24 ANTIGEN
    ROSEN, SM
    ALLEN, CC
    FELDMAN, M
    WAKSAL, SD
    AIDS RESEARCH AND HUMAN RETROVIRUSES, 1990, 6 (01) : 40 - 40
  • [38] COMPARISON OF CORE ANTIGEN (P24) ASSAY AND REVERSE-TRANSCRIPTASE ACTIVITY FOR DETECTION OF HUMAN IMMUNODEFICIENCY VIRUS TYPE-1 REPLICATION
    LAND, S
    BEATON, F
    MCPHEE, DA
    GUST, ID
    JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (03) : 486 - 489
  • [39] CLINICAL UTILITY OF AN ENHANCED HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 P24 ANTIGEN CAPTURE ASSAY
    VASUDEVACHARI, MB
    SALZMAN, NP
    WOLL, DR
    MAST, C
    UFFELMAN, KW
    TOEDTER, G
    HOEFHEINZ, D
    METCALF, JA
    LANE, HC
    JOURNAL OF CLINICAL IMMUNOLOGY, 1993, 13 (03) : 185 - 192
  • [40] Cost-effectiveness of p24 antigen testing in preventing transfusion transmission of human immunodeficiency virus infection - Reply
    Busch, MP
    Alter, HJ
    TRANSFUSION, 1996, 36 (04) : 382 - 383