Validation and application of a fast semi-automated whole blood extraction for LC-MS/MS simultaneous quantification of cyclosporine A, tacrolimus, sirolimus and everolimus - application to high throughput routine therapeutic drug monitoring

被引:7
|
作者
Bouquie, Regis [1 ,2 ]
Deslandes, Guillaume [1 ]
Renaud, Christian [1 ]
Dailly, Eric [1 ,2 ]
Jolliet, Pascale [1 ,2 ]
机构
[1] Hosp Univ Nantes, Dept Clin Pharmacol, Nantes, France
[2] Hosp Univ Nantes, EA Biostat Pharmacoepidemiol & Mesures Subject Sa, Nantes, France
关键词
TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; TRANSPLANT; ROBUST;
D O I
10.1039/c3ay40603b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Numerous laboratories carried out simultaneous whole blood quantitation of everolimus, sirolimus, tacrolimus and cyclosporine-A on a liquid chromatography-tandem mass-spectrometry (LC-MS/MS) system with online solid phase extraction (SPE) after manual deproteinization and centrifugation. This method had a relatively low sample throughput due to labor intensive and time-consuming sample preparation. We develop a fast and robust method of semi-automated whole blood sample pretreatment able to support over 120 samples daily. Whole blood samples were mixed in a V-bottom plate with 2 volumes of ZnSO4/methanol containing deuterated internal standards. After centrifugation, the supernatant was loaded on an online-SPE before being transferred and monitored on the LC-MS/MS system. Assay performance included inter-and intra-day accuracy and imprecision, relative and absolute matrix effects, extraction recovery and selectivity. Intra-and inter-day imprecision was <15% for all tested concentrations. The lower limit of quantification of cyclosporine-A, everolimus, sirolimus and tacrolimus was respectively 26.6, 1.13, 1.57 and 1.28 ng mL(-1), with an accuracy between -0.63% and 11.48% and a precision <12% of the nominal concentration. Standard line slope imprecision did not exceed 20% and ion enhancement or suppression was negligible. The comparison methods were performed by Passing and Bablok regression analysis: a high correlation was found between the two pre-treatment methods for tacrolimus, everolimus and sirolimus and between LC-MS/MS vs. radio-immuno-assay for cyclosporine-A. We developed a fast, sound and less misleading analytical method for high throughput (over 120 samples daily) therapeutic drug monitoring of multiple immunosuppressive drugs in routine practice.
引用
收藏
页码:5079 / 5088
页数:10
相关论文
共 50 条
  • [41] Development and validation of a novel method for simultaneous quantification of enzalutamide, darolutamide and their active metabolites in mice dried blood spots using LC-MS/MS: application to pharmacokinetic study in mice
    Saini, Neraj Kumar
    Sulochana, Suresh P.
    Zainuddin, Mohd
    Mullangi, Ramesh
    ADMET AND DMPK, 2018, 6 (03): : 242 - 257
  • [42] Development and validation of ultrafast LC-MS/MS method for quantification of anti-influenza agent camphecene in whole rat blood using dried blood spots and its application to pharmacokinetic studies
    Rogachev, Artem D.
    Yarovaya, Olga I.
    Ankov, Sergey V.
    Khvostov, Mikhail V.
    Tolstikova, Tatyana G.
    Pokrovsky, Andrey G.
    Salakhutdinov, Nariman F.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1036 : 136 - 141
  • [43] Detection and Validated Quantification of the Phosphodiesterase Type 5 Inhibitors Sildenafil, Vardenafil, Tadalafil, and 2 of Their Metabolites in Human Blood Plasma by LC-MS/MS-Application to Forensic and Therapeutic Drug Monitoring Cases
    Rust, Kristina Y.
    Wilkens, Heinrike
    Kaiser, Ralf
    Bregel, Dietmar
    Wilske, Jochen
    Kraemer, Thomas
    THERAPEUTIC DRUG MONITORING, 2012, 34 (06) : 729 - 735
  • [44] Development and validation of a high throughput and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of diltiazem and its two metabolites in human plasma: Application to a bioequivalence study
    Dasandi, Bhavesh
    Shah, Sanjay
    Shivprakash
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (8-9): : 791 - 798
  • [45] Development and validation of a UPLC-MS/MS method for simultaneous quantification of levofloxacin, ciprofloxacin, moxifloxacin and rifampicin in human plasma: Application to the therapeutic drug monitoring in osteoarticular infections
    LLopis, Benoit
    Funck-Brentano, Christian
    Tissot, Nadine
    Bleibtreu, Alexandre
    Jaureguiberry, Stephane
    Fourniols, Eric
    Aubry, Alexandra
    Zahr, Noel
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 183
  • [46] Simultaneous determination of 11 oral targeted antineoplastic drugs and 2 active metabolites by LC-MS/MS in human plasma and its application to therapeutic drug monitoring in cancer patients
    Zhao, Jing
    Yan, Dongming
    Li, Yue
    Xu, Xiaoqing
    Li, Fengling
    Zhang, Shuang
    Jin, Jingyi
    Qiu, Furong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1237
  • [47] Simultaneous monitoring of seven antiepileptic drugs by dried blood spot and dried plasma spot sampling: method validation and clinical application of a LC-MS/MS-based technique
    Cao, Haiwei
    Jiang, Yi
    Sun, Qiang
    Liu, Ruichen
    Li, Yanyan
    Huang, Jing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 243
  • [48] Development and validation of an LC-MS/MS method for the quantification of the anthelmintic drug moxidectin in a volumetric absorptive microsample, blood, and plasma: Application to a pharmacokinetic study of adults infected with Strongyloides stercoralis in Laos
    Hofmann, Daniela
    Sayasone, Somphou
    Keiser, Jennifer
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1166
  • [49] Simultaneous and rapid determination of 12 tyrosine kinase inhibitors by LC-MS/MS in human plasma: Application to therapeutic drug monitoring in patients with non-small cell lung cancer
    Zhou, Lijuan
    Wang, Shuowen
    Chen, Ming
    Huang, Shiqi
    Zhang, Min
    Bao, Wuping
    Bao, Aihua
    Zhang, Pengyu
    Guo, Haiying
    Liu, Zhenwei
    Xie, Guogang
    Gao, Jianwei
    Wu, Zhenghua
    Lou, Yuefen
    Fan, Guorong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1175
  • [50] Development and validation of an LC-MS/MS method for the quantification of the anthelmintic drug moxidectin in a volumetric absorptive microsample, blood, and plasma: Application to a pharmacokinetic study of adults infected with Strongyloides stercoralis in Laos
    Hofmann, Daniela
    Sayasone, Somphou
    Keiser, Jennifer
    Keiser, Jennifer (jennifer.keiser@swisstph.ch), 2021, Elsevier B.V. (1166):