Validation and application of a fast semi-automated whole blood extraction for LC-MS/MS simultaneous quantification of cyclosporine A, tacrolimus, sirolimus and everolimus - application to high throughput routine therapeutic drug monitoring

被引:7
|
作者
Bouquie, Regis [1 ,2 ]
Deslandes, Guillaume [1 ]
Renaud, Christian [1 ]
Dailly, Eric [1 ,2 ]
Jolliet, Pascale [1 ,2 ]
机构
[1] Hosp Univ Nantes, Dept Clin Pharmacol, Nantes, France
[2] Hosp Univ Nantes, EA Biostat Pharmacoepidemiol & Mesures Subject Sa, Nantes, France
关键词
TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; TRANSPLANT; ROBUST;
D O I
10.1039/c3ay40603b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Numerous laboratories carried out simultaneous whole blood quantitation of everolimus, sirolimus, tacrolimus and cyclosporine-A on a liquid chromatography-tandem mass-spectrometry (LC-MS/MS) system with online solid phase extraction (SPE) after manual deproteinization and centrifugation. This method had a relatively low sample throughput due to labor intensive and time-consuming sample preparation. We develop a fast and robust method of semi-automated whole blood sample pretreatment able to support over 120 samples daily. Whole blood samples were mixed in a V-bottom plate with 2 volumes of ZnSO4/methanol containing deuterated internal standards. After centrifugation, the supernatant was loaded on an online-SPE before being transferred and monitored on the LC-MS/MS system. Assay performance included inter-and intra-day accuracy and imprecision, relative and absolute matrix effects, extraction recovery and selectivity. Intra-and inter-day imprecision was <15% for all tested concentrations. The lower limit of quantification of cyclosporine-A, everolimus, sirolimus and tacrolimus was respectively 26.6, 1.13, 1.57 and 1.28 ng mL(-1), with an accuracy between -0.63% and 11.48% and a precision <12% of the nominal concentration. Standard line slope imprecision did not exceed 20% and ion enhancement or suppression was negligible. The comparison methods were performed by Passing and Bablok regression analysis: a high correlation was found between the two pre-treatment methods for tacrolimus, everolimus and sirolimus and between LC-MS/MS vs. radio-immuno-assay for cyclosporine-A. We developed a fast, sound and less misleading analytical method for high throughput (over 120 samples daily) therapeutic drug monitoring of multiple immunosuppressive drugs in routine practice.
引用
收藏
页码:5079 / 5088
页数:10
相关论文
共 50 条
  • [1] Robust, High-Throughput LC-MS/MS Method for Therapeutic Drug Monitoring of Cyclosporine, Tacrolimus, Everolimus, and Sirolimus in Whole Blood
    Koster, Reinco A.
    Dijkers, Eli C. F.
    Uges, Donald R. A.
    THERAPEUTIC DRUG MONITORING, 2009, 31 (01) : 116 - 125
  • [2] Therapeutic drug monitoring of immunosuppressive drugs: Simultaneous quantification of sirolimus, everolimus, tacrolimus, and cyclosporine by LC-MS
    Kaever, V
    Kirchner, G
    Resch, K
    Deters, M
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2002, 365 : R111 - R111
  • [3] Improved LC-MS/MS method for the simultaneous quantification of tacrolimus and cyclosporine A in human blood and application to therapeutic drug monitoring
    Chen, Feng
    Yang, Xiaoxia
    Li, Huanhuan
    Zeng, Xiaodan
    Deng, Ziwei
    Wang, Hongqiang
    Jin, Yuanxiang
    Qiu, Chengfeng
    Shi, Zhihua
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (12)
  • [4] Simultaneous Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus in Whole-Blood Samples by LC-MS/MS
    Karapirli, Mustafa
    Kizilgun, Murat
    Yesilyurt, Ozgur
    Gul, Husamettin
    Kunak, Zeki Ilker
    Akgul, Emin Ozgur
    Macit, Enis
    Cayci, Tuncer
    Kurt, Yasemin Gulcan
    Aydin, Ibrahim
    Yaren, Hakan
    Seyrek, Melik
    Cakir, Erdinc
    Yaman, Halil
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [5] Simultaneous quantification of cyclosporin, tacrolimus, sirolimus and everolimus in whole blood by UHPLC–MS/MS for therapeutic drug monitoring
    Antunes, Natalicia J.
    Kipper, Karin
    Couchman, Lewis
    Duncan, Marie-Anne
    Holt, David W.
    De Nucci, Gilberto
    Johnston, Atholl
    Antunes, Natalicia J. (nataliciaja@gmail.com), 2021, John Wiley and Sons Ltd (35)
  • [6] Simultaneous quantification of cyclosporin, tacrolimus, sirolimus and everolimus in whole blood by UHPLC-MS/MS for therapeutic drug monitoring
    Antunes, Natalicia J.
    Kipper, Karin
    Couchman, Lewis
    Duncan, Marie-Anne
    Holt, David W.
    De Nucci, Gilberto
    Johnston, Atholl
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (06)
  • [7] A new HPLC-MS/MS method for simultaneous determination of Cyclosporine A, Tacrolimus, Sirolimus and Everolimus for routine therapeutic drug monitoring
    Krnac, Dusan
    Reiffova, Katarina
    Rolinski, Boris
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1128
  • [8] An isotope dilution LC-MS/MS based candidate reference method for the quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human whole blood
    Taibon, Judith
    van Rooij, Milou
    Schmid, Rupert
    Singh, Neeraj
    Albrecht, Eva
    Wright, Jo Anne
    Geletneky, Christian
    Schuster, Carina
    Moerlein, Sophie
    Vogeser, Michael
    Seger, Christoph
    Pongratz, Stephan
    Kobold, Uwe
    CLINICAL BIOCHEMISTRY, 2020, 82 : 73 - 84
  • [9] Validation of an automated whole blood extraction coupled with liquid chromatography/tandem mass spectrometry assay applied to high throughput routine therapeutic drug monitoring of cyclosporine A, tacrolimus, everolimus and sirolimus
    Deslandes, G.
    Gregoire, M.
    Renaud, C.
    Monteil-Ganiere, C.
    Azoulay, C.
    Pineau, A.
    Evin, P. Jolliet
    Dailly, E.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2016, 30 : 47 - 47
  • [10] Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography-mass spectrometry (LC-MS)
    Deters, M
    Kirchner, G
    Resch, K
    Kaever, V
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (03) : 285 - 292