Study on short failure localization approach by newly developed EBAC technique

被引:0
|
作者
Fuse, Junichi [1 ]
Sunaoshi, Takeshi [1 ]
Nara, Yasuhiko [1 ]
Kageyama, Akira [1 ]
Mizuno, Takayuki [2 ]
机构
[1] Hitachi High Technol Corp, Sci Syst Design Div, 1040 Ichige, Hitachinaka, Ibaraki 3120033, Japan
[2] Hitachi High Technol Corp, Sci Syst Sales & Mkt Div, Minato Ku, 1-24-14,Nishi Shimbashi 1 Chome, Tokyo 1058717, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Demand of short failure analysis has been increasing in semiconductor failure analysis. It is known from the previous studies that many short failure analysis methods are suggested. However, it is extremely difficult to identify the short failure location in recent advanced devices due to the fact of optical resolution limit. On the other hand EBAC has been noted as the high resolution method to identify an open or a high resistance failure while it is rather difficult for EBAC to identify a short failure. In this study we have developed a new EBAC amplifier and evaluated a short failure case for identifying the location clearer enough than conventional analysis methods. This paper describes successful use of the new EBAC amplifier which has sufficient enough resolution of EBAC signal to identify the failure locations for next step physical analyses of FIB, STEM or so on.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] A NEWLY DEVELOPED WARM EXTRUSION TECHNIQUE FOR COMPACTING AMORPHOUS ALLOY POWDERS
    KAWAMURA, Y
    TAKAGI, M
    AKAI, M
    IMURA, T
    MATERIALS SCIENCE AND ENGINEERING, 1988, 98 : 449 - 452
  • [32] Newly developed on-line continuous hemodiafiltration for acute liver failure
    Inoue, Kazuaki
    HEPATOLOGY RESEARCH, 2021, 51 (02) : 154 - 155
  • [33] Mortal Interaction Between Hemophagocytic Syndrome and Newly Developed Heart Failure
    Bozkurt, Devrim
    Bozgul, Sukriye Miray Kilincer
    Emgin, Omer
    Butun, Osman
    Kose, Timur
    Simsek, Evrim
    Hekimgil, Mine
    Kilic, Salih
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2021, 116 (03) : 395 - 401
  • [34] PRETREATMENT TECHNIQUE OF HOT METAL BY NEWLY DEVELOPED REFINING FURNACE.
    Ohnishi, Toshiyasu
    Takagi, Hiroshi
    Ogura, Tetsuzo
    Hajika, Kiminori
    Yabata, Takeshi
    Yoshida, Yasuo
    R and D: Research and Development Kobe Steel Engineering Reports, 1986, 36 (01): : 9 - 13
  • [35] Optimization of pit limit designs by the newly developed BPITC approach
    Dindiwe, C
    Sasaki, K
    COMPUTER APPLICATIONS IN THE MINERALS INDUSTRIES, 2001, : 249 - 255
  • [36] A study of a calibration technique for a newly developed thyroid monitor and its uncertainties due to body size for radioiodine measurements
    Yoshitomi, H.
    Nishino, S.
    Tanimura, Y.
    Takahashi, M.
    RADIATION MEASUREMENTS, 2020, 133
  • [37] A newly developed test rig for the study of thermal fatigue
    Fazarinc, M.
    Turk, R.
    Kugler, G.
    Tercelj, M.
    COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS XIII, 2007, 46 : 45 - +
  • [38] EEG STUDY OF A NEWLY DEVELOPED GENETICALLY EPILEPTIC RAT
    IKEDA, M
    UEMURA, S
    AMANO, S
    IHARA, N
    HAZAMA, F
    EPILEPSIA, 1995, 36 : S49 - S49
  • [39] Parametric Study of a Newly Developed Magnetorheological Honing Process
    Bedi, Talwinder Singh
    Singh, Anant Kumar
    ADVANCES IN UNCONVENTIONAL MACHINING AND COMPOSITES, AIMTDR 2018, 2020, : 483 - 491
  • [40] The Durability and Performance of Short Fibers for a Newly Developed Alkali-Activated Binder
    Funke, Henrik
    Gelbrich, Sandra
    Kroll, Lothar
    FIBERS, 2016, 4 (01):