CLIMT - model and program for the prediction of the indoor air temperature and indoor air relative humidity

被引:0
|
作者
Haeupl, P. [1 ]
Bishara, A. [1 ]
Hansel, F. [2 ]
机构
[1] Tech Univ Dresden, Fac Architecture, Inst Bldg Climatol, Dresden, Germany
[2] Univ Lausitz Cottbus, Cottbus, Germany
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The solution of the simplified thermic and hygric room balance equations and adjacent walls are compared in selected application cases. The model is first reviewed and then applied to scenarios designed to illustrate the experimental and calculation results. For the common professional use the user friendly program CLIMT has been developed.
引用
收藏
页码:485 / 492
页数:8
相关论文
共 50 条
  • [41] Adverse environmental health effects of ultra-low relative humidity indoor air
    Sato, M
    Fukayo, S
    Yano, E
    JOURNAL OF OCCUPATIONAL HEALTH, 2003, 45 (02) : 133 - 136
  • [42] MULTIVARIABLE CONTROL OF INDOOR AIR TEMPERATURE AND HUMIDITY IN A DIRECT EXPANSION (DX) AIR CONDITIONING (A/C) SYSTEM
    Qi, Qi
    Deng, Shiming
    PROCEEDINGS OF THE FIRST INTERNATIONAL POSTGRADUATE CONFERENCE ON INFRASTRUCTURE AND ENVIRONMENT, 2009, : 62 - 69
  • [43] Multivariable control of indoor air temperature and humidity in a direct expansion (DX) air conditioning (A/C) system
    Qi, Qi
    Deng, Shiming
    BUILDING AND ENVIRONMENT, 2009, 44 (08) : 1659 - 1667
  • [44] A thermal environmental model for indoor air temperature prediction and energy consumption in pig building
    Xie, Qiuju
    Ni, Ji-Qin
    Bao, Jun
    Su, Zhongbin
    BUILDING AND ENVIRONMENT, 2019, 161
  • [45] Ventilation and house air tightness: Effect on indoor temperature and humidity in Southampton, UK
    Stephen, F.R.
    McIntyre, D.A.
    Lane, A.
    Raw, G.J.
    Wiech, C.R.
    Frederick, J.
    Building Services Engineering Research and Technology, 1997, 18 (03): : 141 - 147
  • [46] Evaluation of the Johnson and Ettinger model for prediction of indoor air quality
    Hers, I
    Zapf-Gilje, R
    Johnson, PC
    Li, L
    GROUND WATER MONITORING AND REMEDIATION, 2003, 23 (02): : 119 - 133
  • [47] Evaluation of the Johnson and Ettinger model for prediction of indoor air quality
    Hers, I
    Zapf-Gilje, R
    Johnson, PC
    Li, L
    GROUND WATER MONITORING AND REMEDIATION, 2003, 23 (01): : 62 - 76
  • [48] INDOOR AIR-90 - CHARACTERIZATION OF INDOOR AIR
    WALKINSHAW, DS
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (12): : 2137 - 2139
  • [49] On indoor air pollution and indoor air quality control
    Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Chongqing University, Chongqing 400045, China
    不详
    Chongqing Jianzhu Daxue Xuebao, 2007, 6 (108-112):
  • [50] The Impact of Indoor Air Humidity on the Infiltration of Ambient Particles
    Qiu, Jiayi
    Zhang, Haixi
    Liu, Jialu
    Liu, Yanhua
    BUILDINGS, 2024, 14 (04)