Langmuir probe measurements of plasma parameters in a planar magnetron with additional plasma confinement

被引:30
|
作者
Spatenka, P
Vlcek, J
Blazek, J
机构
[1] Univ S Bohemia, Fac Biol Sci, Dept Math Phys & Chem, Ceske Budejovice 37005, Czech Republic
[2] Univ W Bohemia, Fac Sci Appl, Plzen 30614, Czech Republic
[3] Univ S Bohemia, Coll Educ, Ceske Budejovice 37115, Czech Republic
关键词
D O I
10.1016/S0042-207X(99)00144-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Langmuir probe measurements have been carried out in a planar magnetron sputtering system with an additional plasma confinement which can be operated at low argon pressures (down to 3.4 x 10(-2) Pa) when target utilization greater than 80% can be achieved. The electron density, electron temperature, relative densities of low- and high-energy groups of electrons and the difference between the plasma and floating potential have been determined in various positions between the target and a substrate at the argon pressures in the range from 0.05 to 5 Pa. It has been proved that the additional magnetic field results, particularly in larger distances from the target at lower pressures, in the formation of structured electron energy distributions with a substantial contribution from a high-energy group of electrons, which is responsible for enhanced gas ionization and relatively high values observed for the difference between the plasma and the floating potential. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [41] THE POSITIVELY BIASED PLANAR LANGMUIR PROBE IN A HIGH-PRESSURE PLASMA
    CLEMENTS, RM
    SMY, PR
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (11) : 1916 - 1920
  • [42] Triple Langmuir Probe Measurements in The Plasma Generated by Hypervelocity Impact
    Zhang Dong-jiang
    Zhang Qing-ming
    2011 3RD WORLD CONGRESS IN APPLIED COMPUTING, COMPUTER SCIENCE, AND COMPUTER ENGINEERING (ACC 2011), VOL 4, 2011, 4 : 618 - 624
  • [44] Langmuir probe measurements in a complex plasma under microgravity conditions
    Klindworth, M
    Melzer, A
    Piel, A
    Konopka, U
    Morfill, GE
    DUSTY PLASMAS IN THE NEW MILLENNIUM, 2002, 649 : 345 - 348
  • [45] LANGMUIR PROBE MEASUREMENTS OF SCRAPE-OFF PLASMA IN PLT
    BARNES, CW
    COHEN, SA
    DYLLA, HF
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1140 - 1140
  • [46] Triple Langmuir probe measurements in the plume of a pulsed plasma thruster
    Eckman, R
    Byrne, L
    Gatsonis, NA
    Pencil, EJ
    JOURNAL OF PROPULSION AND POWER, 2001, 17 (04) : 762 - 771
  • [47] APPLICATION OF WARM LANGMUIR PROBE IN THE PLASMA MEASUREMENTS INSIDE PLASMA-CHEMICAL REACTOR
    KALCIK, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1995, 45 (03) : 241 - 248
  • [48] Optimization of Langmuir probe system parameters in a stationary laboratory plasma
    Zhu Ying
    Cao Jinxiang
    Niu Tianye
    Wang Liang
    Wang Yan
    Wang Ge
    PLASMA SCIENCE & TECHNOLOGY, 2006, 8 (06) : 639 - 643
  • [49] Optimization of Langmuir Probe System Parameters in a Stationary Laboratory Plasma
    朱颖
    曹金祥
    牛田野
    王亮
    王艳
    王舸
    Plasma Science and Technology, 2006, 8 (06) : 639 - 643
  • [50] Optimization of Langmuir Probe System Parameters in a Stationary Laboratory Plasma
    朱颖
    曹金祥
    牛田野
    王亮
    王艳
    王舸
    Plasma Science and Technology, 2006, (06) : 639 - 643