The Effect of Axial Torsion on the Mechanical Properties of the Annulus Fibrosus

被引:19
|
作者
Harvey-Burgess, Maxine [1 ]
Gregory, Diane E. [1 ,2 ]
机构
[1] Wilfrid Laurier Univ, Dept Kinesiol & Phys Educ, 75 Univ Ave West, Waterloo, ON N2L 3C5, Canada
[2] Wilfrid Laurier Univ, Dept Hlth Sci, 75 Univ Ave West, Waterloo, ON N2L 3C5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
anulus fibrosus; bovine; injury; intralamellar matrix; twist; INTERVERTEBRAL DISC; LUMBAR; PORCINE; DAMAGE; ARCHITECTURE; HERNIATION;
D O I
10.1097/BRS.0000000000002803
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In-vitro study of the tissue mechanics of annulus fibrosus. Objective. To determine the effect of axial torsion on the mechanical properties of the inter-and intralamellar matrices. Summary of Background Data. Axial torsion, when combined with repetitive flexion, has been associated with an increased risk of intervertebral disc herniation. However, the mechanisms behind this relationship are poorly understood. Methods. Bovine intervertebral discs (IVDs) from the caudal region were exposed to a combination of either 08 or 128 of static axial torsion and 0N or 1000N of compression for 2 hours in an attempt to created micro-damage to the IVD. Following the loading protocol, one multilayered sample and two single layer samples were dissected from the annulus fibrosus to undergo tensile testing of the inter-and intralamellar matrices. Histological staining was also performed. Results. The strength of the interlamellar matrix was not affected by axial torsion or compression, suggesting that torsion did not damage the interlamellar matrix. However, intralamellar matrix strength of samples exposed to axial torsion, regardless of compressive loading magnitude, was 48% lower than those from samples that were not exposed to torsion (P<0.001). Similarly, intralamellar matrix stiffness of samples exposed to axial torsion was 42% lower than from samples that were not exposed to torsion (P = 0.010). Additionally, histological analysis demonstrated more disruption within individual lamellae of the samples exposed to axial torsion compared with samples that were not. Conclusion. This study suggests that axial torsion damages the components of the intralamellar matrix as a result of the strain it puts on the matrix, thus making the intervertebral disc more susceptible to herniation.
引用
收藏
页码:E195 / E201
页数:7
相关论文
共 50 条
  • [41] Confined compression of canine annulus fibrosus under chemical and mechanical loading
    Drost, MR
    Willems, P
    Snijders, H
    Huyghe, JM
    Janssen, JD
    Huson, A
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (04): : 390 - 396
  • [42] Mechanical damage to the initervertebral disc annulus fibrosus subjected to tensile loading
    Iatridis, JC
    MacLean, JJ
    Ryan, DA
    JOURNAL OF BIOMECHANICS, 2005, 38 (03) : 557 - 565
  • [43] Polyurethane tissue adhesives for annulus fibrosus repair: Mechanical restoration and cytotoxicity
    Agnol, Lucas Dall
    Gonzalez Dias, Fernanda Trindade
    Nicoletti, Natalia Fontana
    Marinowic, Daniel
    Moura e Silva, Sidnei
    Marcos-Fernandez, Angel
    Falavigna, Asdrubal
    Bianchi, Otavio
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2019, 34 (05) : 673 - 686
  • [44] Confined compression of canine annulus fibrosus under chemical and mechanical loading
    Drost, M.R.
    Willems, P.
    Snijders, H.
    Huyghe, J.M.
    Janssen, J.D.
    Huson, A.
    Journal of Biomechanical Engineering, 1995, 117 (04): : 390 - 396
  • [45] A SIMPLIFIED STRAIN ENERGY FUNCTION TO REPRESENT THE MECHANICAL BEHAVIOR OF THE ANNULUS FIBROSUS
    Garcia, Jose J.
    Puttlitz, Christian
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 121 - 122
  • [46] Numerical Investigation of the Annulus Fibrosus
    Subramanian, Gopinath
    Linley, Sarah
    Ledet, Eric
    Ozisik, Rahmi
    2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2011,
  • [47] CALCIFICATION OF THE LEFT ANNULUS FIBROSUS
    GEILL, T
    JOURNALS OF GERONTOLOGY, 1951, 6 (04): : 327 - 333
  • [48] A homogenization model of the annulus fibrosus
    Yin, LZ
    Elliott, DM
    JOURNAL OF BIOMECHANICS, 2005, 38 (08) : 1674 - 1684
  • [49] Repair of annulus fibrosus defects using decellularized annulus fibrosus matrix/chitosan hybrid hydrogels
    Liu, Chen
    Ge, Xin
    Li, Yifeng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [50] Clinical effect of full endoscopic lumbar annulus fibrosus suture
    Peng, Yin-xiao
    Zhang, Yue
    Yang, Yun
    Wang, Fei
    Yu, Bin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)