Noise filtration in fluorescence-enhanced optical tomography: breast phantom studies

被引:1
|
作者
Zhu, Banghe [1 ]
Sevick-Muraca, Eva M. [2 ]
Eppstein, Margaret J. [3 ]
Godavarty, Anuradha [1 ]
机构
[1] Florida Int Univ, Dept Biomed Engn, Miami, FL 33199 USA
[2] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[3] Univ Vermont, Dept Comp Sci, Burlington, VT USA
关键词
noise pre-filtration; fluorescence-enhanced optical tomography; optical imaging technique; IN-VIVO;
D O I
10.1080/17415970802083482
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Noisy measurements may impact the quality of image reconstructions in fluorescence-enhanced optical tomography studies. In this contribution, different noise pre-filtration techniques were developed using fluorescence measurements of homogeneous breast phantoms. The noise pre-filtration techniques were determined based on correlation studies among various measurement parameters. We demonstrated that noise pre-filtration techniques can improve the target localization in image reconstructions when the target is deeply located (2 cm) in imperfect uptake case (i.e. target: background fluorescence absoroption contrast ratio of 100 : 1). Moreover, filtration of measurement noise using different criteria can possibly differentiate the target from artifacts, potentially minimizing the false-positive cases in a clinical environment.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [1] Diagnostic imaging of breast cancer using fluorescence-enhanced optical tomography: phantom studies
    Godavarty, A
    Thompson, AB
    Roy, R
    Gurfinkel, M
    Eppstein, MJ
    Zhang, C
    Sevick-Muraca, EM
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (03) : 488 - 496
  • [2] Noise pre-filtering techniques in fluorescence-enhanced optical tomography
    Zhu, B.
    Eppstein, M. J.
    Sevick-Muraca, E. M.
    Godavarty, A.
    OPTICS EXPRESS, 2007, 15 (18) : 11285 - 11300
  • [3] Fluorescence-enhanced optical tomography of a large tissue phantom using point illumination geometries
    Roy, Ranadhir
    Godavarty, Anuradha
    Sevick-Muraca, Eva M.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
  • [4] Fluorescence-enhanced Optical Tomography using Phase Information
    Lu, Yujie
    Sevick-Muraca, Eva M.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [5] Near-Infrared Fluorescence-Enhanced Optical Tomography
    Zhu, Banghe
    Godavarty, Anuradha
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [6] Fluorescence-enhanced optical imaging and tomography for cancer diagnostics
    Sevick-Muraca, EM
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1482 - 1485
  • [7] Reduction of noise floor for molecular, fluorescence-enhanced optical imaging
    Zhu, Banghe
    Rasmussen, John C.
    Lu, Yujie
    Sevick-Muraca, Eva M.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IV, 2011, 7891
  • [8] Multiple step algorithm for fluorescence-enhanced diffuse optical tomography
    Da Silva, A
    Planat-Chrétien, A
    Dinten, JM
    Glière, A
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VI, 2005, 5693 : 210 - 220
  • [9] Telegrapher based fluorescence-enhanced optical tomography in small volume
    Roy, Ranadhir
    OPTICAL BIOPSY VII, 2010, 7561
  • [10] Fluorescence-enhanced optical tomography using referenced measurements of heterogeneous media
    Roy, R
    Godavarty, A
    Sevick-Muraca, EM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (07) : 824 - 836