Monte Carlo simulation of beta depth dose distributions in LiF

被引:1
|
作者
Miralles, H [1 ]
Duch, MA [1 ]
Ginjaume, M [1 ]
Ortega, X [1 ]
机构
[1] Univ Politecn Catalunya, Inst Tech Energet, E-08028 Barcelona, Spain
关键词
D O I
10.1093/oxfordjournals.rpd.a032914
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The accurate measurement of weakly penetrating radiation is usually difficult due to the attenuation of the radiation in the detector. The aim of this work is to estimate by means of Monte Carlo techniques beta depth-dose distributions in LiF dosemeters of different thicknesses. The new Monte Carlo code for electron-photon simulation, PENELOPE, developed at the University of Barcelona, is used in this study. The Amersham/Buchler beta secondary standard usually used for the calibration of beta dosemeters is simulated. The irradiation unit and geometries are taken into account for the calculations. Depth dose distributions in 105 mg.cm(-2) and 240 mg.cm(-2) thick detectors produced by Tl-204 and Sr-90-Y-90 reference sources at a surface-source distance of 30 cm are calculated. Subsequently, detector responses are evaluated for the two detector thicknesses and the two beta sources and compared with experimental data. Results agree within estimated uncertainties (+/-10%).
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [1] MONTE-CARLO CALCULATIONS OF MONOENERGETIC ELECTRON DEPTH-DOSE DISTRIBUTIONS IN LIF CHIPS - SKIN DOSE CORRECTION FACTORS FOR BETA-RAYS
    HOROWITZ, YS
    HIRNING, CR
    YUEN, P
    WONG, P
    [J]. HEALTH PHYSICS, 1994, 67 (04): : 330 - 337
  • [2] MONTE-CARLO CALCULATION OF ELECTRON DEPTH DOSE DISTRIBUTIONS
    SCHRIBER, SO
    FUNK, LW
    MOWCHENKO, JT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 573 - 573
  • [3] Monte carlo simulation of surface percent depth dose
    Lin, SY
    Chu, TC
    Lin, JP
    Huang, CY
    [J]. APPLIED RADIATION AND ISOTOPES, 2002, 56 (03) : 505 - 510
  • [4] Radial energy distributions in LiF by alpha particle irradiation using Monte Carlo simulation
    Avila, O
    Brandan, ME
    Salvat, F
    FernandezVarea, JM
    [J]. RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 37 - 40
  • [5] Denoising of Monte Carlo dose distributions
    Deasy, JO
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1494 - 1496
  • [6] Monte Carlo dose distributions for radiosurgery
    Perucha, M
    Sánchez-Doblado, F
    Leal, A
    Rincón, M
    Núnez, L
    Arráns, R
    Carrasco, E
    Sánchez-Nieto, B
    Sánchez-Calzado, JA
    Errazquin, L
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 561 - 564
  • [7] Comparison of measured and Monte Carlo-calculated electron depth dose distributions in aluminium
    Vandana, S.
    Benny, P. G.
    Selvam, T. Palani
    [J]. INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (01) : 48 - 52
  • [8] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [9] A Monte Carlo simulation study of Nitrogen on LiF(001)
    Sallabi, A. K.
    Dawoud, J. N.
    Jack, D. B.
    [J]. APPLIED SURFACE SCIENCE, 2010, 256 (09) : 2974 - 2978
  • [10] Kinetics and depth distributions of oxygen implanted into Si analyzed by the Monte Carlo simulation of extended TRIM
    Yoneda, T
    Kajiyama, K
    Tohjou, F
    Yoshioka, Y
    Ikeda, A
    Kisaka, Y
    Nishimura, T
    Kido, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (12A): : 7323 - 7328