Towards an inline reconstruction architecture for micro-CT systems

被引:28
|
作者
Brasse, D
Humbert, B
Mathelin, C
Rio, MC
Guyonnet, JL
机构
[1] Univ Strasbourg 1, CNRS, Inst Rech Subatom, IN2P3, Strasbourg, France
[2] Inst Genet & Biol Mol & Cellulaire, Illkirch Graffenstaden, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 24期
关键词
D O I
10.1088/0031-9155/50/24/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent developments in micro-CT have revolutionized the ability to examine in vivo living experimental animal models such as mouse with a spatial resolution less than 50 mu m. The main requirements of in vivo imaging for biological researchers are a good spatial resolution, a low dose induced to the animal during the full examination and a reduced acquisition and reconstruction time for screening purposes. We introduce inline acquisition and reconstruction architecture to obtain in real time the 3D attenuation map of the animal fulfilling the three previous requirements. The micro-CT system is based on commercially available x-ray detector and micro-focus x-ray source. The reconstruction architecture is based on a cluster of PCs where a dedicated communication scheme combining serial and parallel treatments is implemented. In order to obtain high performance transmission rate between the detector and the reconstruction architecture, a dedicated data acquisition system is also developed. With the proposed solution, the time required to filter and backproject a projection of 2048 x 2048 pixels inside a volume of 140 mega voxels using the Feldkamp algorithm is similar to 500 ms, the time needed to acquire the same projection.
引用
收藏
页码:5799 / 5811
页数:13
相关论文
共 50 条
  • [1] FAST RECONSTRUCTION METHOD BASED ON COMMON UNIFIED DEVICE ARCHITECTURE (CUDA) FOR MICRO-CT
    Quan, Guotao
    Sun, Tangyou
    Deng, Yong
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2010, 3 (01) : 39 - 43
  • [2] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [3] Statistical reconstruction for X-ray micro-CT systems with noncontinuous detectors.
    Zbijewski, Wojciech
    Beekman, Freek J.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2323 - 2326
  • [4] The Effects of Growth Hormone on Bone Micro-Architecture by In Vivo Micro-CT
    Kristensen, E.
    Hallgrimsson, B.
    Morck, D. W.
    Boyd, S. K.
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S237 - S237
  • [5] Framework for iterative cone-beam micro-CT reconstruction
    Benson, T
    Gregor, J
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3253 - 3257
  • [6] Adaptive region of interest method for analytical micro-CT reconstruction
    Yang, Wanneng
    Xu, Xiaochun
    Bi, Kun
    Zeng, Shaoqun
    Liu, Qian
    Chen, Shangbin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) : 23 - 33
  • [7] Ultra-fast hierarchical backprojection for Micro-CT reconstruction
    Brokish, Jeffrey
    Bresler, Yoram
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4460 - +
  • [8] Framework for iterative cone-beam micro-CT reconstruction
    Benson, TM
    Gregor, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1335 - 1340
  • [9] Image Reconstruction for Hybrid True-Color Micro-CT
    Xu, Qiong
    Yu, Hengyong
    Bennett, James
    He, Peng
    Zainon, Rafidah
    Doesburg, Robert
    Opie, Alex
    Walsh, Mike
    Shen, Haiou
    Butler, Anthony
    Butler, Phillip
    Mou, Xuanqin
    Wang, Ge
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (06) : 1711 - 1719
  • [10] Quantitative micro-CT
    Schladitz, K.
    [J]. JOURNAL OF MICROSCOPY, 2011, 243 (02) : 111 - 117