Seismic performance of bolted connection of H-beam to HSS-column with web end-plate

被引:47
|
作者
Liu, Xue Chun [1 ,2 ]
Cui, Fu Yuan [1 ]
Zhan, Xin Xin [1 ]
Yu, Cheng [3 ]
Jiang, Zi Qin [1 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100124, Peoples R China
[2] Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China
[3] Univ North Texas, Construct Engn Technol Dept Engn Technol, Denton, TX 76207 USA
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Modular steel structure; Bolted connection; Slip at contact surface; Seismic performance; Energy dissipation due to slip; Prefabricated steel structure; CYCLIC BEHAVIOR; STEEL; JOINTS; DUCTILITY; RBS;
D O I
10.1016/j.jcsr.2019.01.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental study on a bolted joint for connecting H-section steel beams to square hollow structural steel (HSS) columns and connecting upper and lower HSS columns in a multi-storey prefabricated steel structure. The components within a module are welded together in the factory, and the modules are assembled on site using high-strength bolts. A rigid connection or a semi-rigid connection can be achieved by adjusting the number and size of bolts. The stiffness of semi-rigid bolted connection changes with the load. The connection is rigid during minor and moderate earthquakes, whereas during major earthquakes, the cover plate slips relative to the beam flange to dissipate energy. In this paper, model tests and finite element analysis (FEA) of the seismic performance under cyclic loads are conducted on six full-scale connections, and the results are compared with the results of a welded connection. The failure mode, slip behaviour, variation and distribution of the bolt tensions, and seismic performance of the connections, including the hysteretic behaviour, skeleton curve, ductility, rotational capacity and stiffness degradation, are obtained. The influences of the number of bolts and the thickness of cover plate on the mechanical and seismic properties are studied. The results show that a reasonable larger bolt hole can facilitate the installation and improve the ductility and energy dissipation capability without significantly affecting the load-carrying capacity of the connection. The results show that the proposed bolted connection has good hysteresis behaviour, energy dissipation and ductility. It is suitable for earthquake-resistant structures. (C) 2019 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:167 / 181
页数:15
相关论文
共 50 条
  • [41] Biaxial cyclic behavior of bolted end-plate connection to I-column reformed by box-plates
    Yilmaz, Orkun
    Bekiroglu, Serkan
    ENGINEERING STRUCTURES, 2022, 255
  • [42] Seismic performance of semi-precast composite columns with bolted end-plate connections to footing
    Kim, Chang-Soo
    Jo, Woo-Bin
    Baek, Seon-Woo
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2022, 259
  • [43] Experimental Investigation of End-Plate Connection with Cruciform Column Section
    Shek, P. N.
    Tahir, M. M.
    Tan, C. S.
    Kueh, A. B. H.
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3730 - 3733
  • [44] Experimental and numerical research on seismic behavior of end-plate connection beam-column joints considering concrete floor effect
    Lu, Shengcan
    Zhang, Jiong
    Wang, Minrong
    Chen, Huiquan
    STRUCTURES, 2024, 65
  • [45] Characterization of the cyclic behavior of the web components in end-plate beam-to-column joints
    Augusto, Hugo
    Castro, Jose Miguel
    Rebelo, Carlos
    da Silva, Luis Simoes
    XVIII INTERNATIONAL COLLOQUIUM ON MECHANICAL FATIGUE OF METALS (ICMFM XVIII), 2016, 160 : 101 - 108
  • [46] Analytical Study of End-Plate Connection on Cruciform Column Section
    Tan, Boon Cheik
    Shek, Poi Ngian
    Tahir, Mahmood Md
    Mu, Ker Shin
    JURNAL TEKNOLOGI, 2015, 74 (04): : 7 - 11
  • [47] Seismic performance of bolted connection between H-section beam and SST column welded with inclined braces
    Liu, Xue-Chun
    Wu, Xiaotong
    Wang, Yue
    Cui, XiaoXiong
    JOURNAL OF BUILDING ENGINEERING, 2022, 61
  • [48] Seismic performance of bolted T-stub Beam-to-Box column connection
    Derakhshan, H.
    Shekastehband, B.
    STRUCTURES, 2023, 56
  • [49] Ductility of the double-sided bolted steel end-plate joint with column web openings under column loss scenario
    Kukla, Damian
    Kozlowski, Aleksander
    Wojcik-Grzaba, Izabela
    STRUCTURES, 2024, 69
  • [50] Behavior of End-Plate Connection with Oversize Holes and Plate Washers for Column Splice
    Lim, Jong-Jin
    Lee, Seung-Hwan
    Eom, Tae-Sung
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (12)