Flow-induced platelet activation in mechanical heart valves

被引:0
|
作者
Bluestein, D
Yin, W
Affeld, K
Jesty, J
机构
[1] SUNY Stony Brook, Hlth Sci Ctr, Dept Biomed Engn, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Med, Div Hematol, Stony Brook, NY 11794 USA
[3] Humboldt Univ, Biofluidmech, Berlin, Germany
来源
JOURNAL OF HEART VALVE DISEASE | 2004年 / 13卷 / 03期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: A study was conducted to measure in vitro the procoagulant properties of platelets induced by flow through mechanical heart valves. Methods: The procoagulant activity of platelets was measured using a real-time assay of platelet activation state (PAS), which was based on a modification of the prothrombinase method. Acetylated prothrombin was used instead of normal prothrombin in this assay in order to eliminate the positive feedback effect of thrombin. This enabled a direct comparison between thrombin generation rates in the assay and the flow stresses that induce platelet activation. Gel-filtered platelets (10(5) per mul) were circulated through a left ventricular assist device with two Bjork-Shiley monoleaflet mechanical heart valves mounted in opposition, and platelet activation state was measured over 30-min time courses. The results were compared with two configurations in which the leaflet motion of one of the valves was restricted (severely restricted and mildly restricted), mimicking defective function of a compromised valve in vivo, and with a control lacking valves. Results. The severely restricted valve activated the platelets at a rate eight-fold higher than with unrestricted valves, and three-fold higher than with mildly restricted valves. Both restricted valves activated platelets at rates significantly higher than either the control (no valves) or the unrestricted valve. Conclusion: Flow through compromised mechanical heart valves causes platelet activation, which can be measured with a modified prothrombinase assay system. The ability to perform sensitive quantitative measurements in cardiovascular devices in vitro may have a significant impact on the design and development of these devices.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 50 条
  • [31] Platelet FLow-Induced PRotrusions (FLIPRs): a landing strip for circulating monocytes
    Tersteeg, C.
    Heijnen, H. F.
    Pasterkamp, G.
    Maas, C.
    Urbanus, R. T.
    Hoefer, I
    Nieuwland, R.
    Farndale, R. W.
    De Groot, P. G.
    Roest, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 449 - 450
  • [32] Rapid flow-induced activation of Gαq/11 is independent of Piezol activation
    dela Paz, Nathaniel G.
    Frangos, John A.
    AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 2019, 316 (05): : C741 - C752
  • [33] Acoustic and visual characteristics of cavitation induced by mechanical heart valves
    Sohn, K
    Manning, KB
    Fontaine, AA
    Tarbell, JM
    Deutsch, S
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (04): : 551 - 558
  • [34] FLOW-INDUCED VIBRATION IN SAFETY RELIEF VALVES - DESIGN AND TROUBLE-SHOOTING METHODS
    BALDWIN, RM
    SIMMONS, HR
    MECHANICAL ENGINEERING, 1984, 106 (08) : 86 - 86
  • [35] Blood damage safety of prosthetic heart valves. Shear-induced platelet activation and local flow dynamics: A fluid-structure interaction approach
    Morbiducci, Umberto
    Ponzini, Raffaele
    Nobili, Matteo
    Massai, Diana
    Montevecchi, Franco Maria
    Bluestein, Danny
    Redaelli, Alberto
    JOURNAL OF BIOMECHANICS, 2009, 42 (12) : 1952 - 1960
  • [36] Coronary flow deserve and flow-induced stimulation of mechanical function in stunned myocardium
    Palombo, C
    Kozakova, M
    Bigalli, G
    Morizzo, C
    Distante, A
    LAbbate, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 93891 - 93891
  • [37] Numerical and experimental measurements of the flow through mechanical heart valves in the natural and artificial heart
    Einav, S
    Avrahami, I
    Rosenfeld, M
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1593 - 1594
  • [38] Flow Visualization in Mechanical Heart Valves: Occluder Rebound and Cavitation Potential
    V. Kini
    C. Bachmann
    A. Fontaine
    S. Deutsch
    J. M. Tarbell
    Annals of Biomedical Engineering, 2000, 28 : 431 - 441
  • [39] Can vortices in the flow across mechanical heart valves contribute to cavitation?
    Avrahami, I
    Rosenfeld, M
    Einav, S
    Eichler, M
    Reul, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (01) : 93 - 97
  • [40] Can vortices in the flow across mechanical heart valves contribute to cavitation?
    I. Avrahami
    M. Rosenfeld
    S. Einav
    M. Eichler
    H. Reul