Liquid argon scintillation read-out with silicon devices

被引:2
|
作者
Canci, N. [1 ,3 ]
Cattadori, C. [2 ]
D'Incecco, M. [3 ]
Lehnert, B. [4 ]
Machado, A. A. [3 ]
Riboldi, S. [5 ,6 ]
Sablone, D. [3 ]
Segreto, E. [3 ]
Vignoli, C. [3 ]
机构
[1] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
[2] INFN Milano Bicocca, Milan, Italy
[3] Ist Nazl Fis Nucl, Lab Nazl Gran Sasso, Assergi, AQ, Italy
[4] Tech Univ Dresden, Inst Kern & Teilchenphys, D-01062 Dresden, Germany
[5] Univ Milan, Dipartimento Fis, Milan, Italy
[6] INFN Milano, Milan, Italy
来源
关键词
Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; SiPMTs; G-APDs; CCDs; EBCCDs; EMCCDs etc); Noble liquid detectors (scintillation; ionization; double-phase); Large detector systems for particle and astroparticle physics; Cryogenic detectors;
D O I
10.1088/1748-0221/8/10/C10007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R&D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm(2) area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R&D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of Ge-76.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] An universal read-out controller
    Manz, S.
    Abel, N.
    Gebelein, J.
    Kebschull, U.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [22] METER READ-OUT FOR VIBROSCOPES
    SNYDER, DD
    MARSH, JK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (02): : 232 - &
  • [23] LCD read-out with no power
    不详
    ELECTRONICS WORLD, 2001, 107 (1783): : 495 - 495
  • [24] Micromachined silicon microcantilevers for gas sensing applications with capacitive read-out
    Amírola, J
    Rodríguez, A
    Castañer, L
    Santos, JP
    Gutiérrez, J
    Horrillo, MC
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 247 - 253
  • [25] Evaluation of silicon micro strip detectors with large read-out pitch
    Hazumi, M
    Kawasaki, T
    Senyo, K
    Nagashima, Y
    Yamamoto, K
    Yamamura, K
    Tsuboyama, T
    Haba, J
    Ikeda, H
    Iwasaki, H
    Matsuda, T
    Ozaki, H
    Tanaka, M
    Yamada, Y
    Okuno, S
    Avrillon, S
    Asano, Y
    Mori, S
    Fukunaga, C
    Hirose, T
    Miyata, H
    Miyano, K
    Banas, E
    Bozek, A
    Natkaniec, Z
    Palka, H
    Rozanska, M
    Rybicki, K
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 515 - 518
  • [26] Evaluation of silicon micro strip detectors with large read-out pitch
    Senyo, K
    Hazumi, M
    Kawasaki, T
    Nagashima, Y
    Yamamoto, K
    Yamamura, K
    Tsuboyama, T
    Haba, J
    Ikeda, H
    Iwasaki, H
    Matsuda, T
    Ozaki, H
    Tanaka, M
    Yamada, Y
    Okuno, S
    Avrillon, S
    Asano, Y
    Mori, S
    Fukunaga, C
    Hirose, T
    Miyata, H
    Miyano, K
    Banas, E
    Bozek, A
    Natkaniec, Z
    Palka, H
    Rozanska, M
    Rybicki, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01): : 123 - 127
  • [27] Evaluation of silicon micro strip detectors with large read-out pitch
    Senyo, K.
    Hazumi, M.
    Kawasaki, T.
    Nagashima, Y.
    Yamamoto, K.
    Yamamura, K.
    Tsuboyama, T.
    Haba, J.
    Ikeda, H.
    Iwasaki, H.
    Matsuda, T.
    Ozaki, H.
    Tanaka, M.
    Yamada, Y.
    Okuno, S.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 383 (01): : 123 - 127
  • [28] Miniaturized read-out interface "Spectrig MAPD'' dedicated for silicon photomultipliers
    Holik, M.
    Ahmadov, F.
    Ahmadov, G.
    Akbarov, R.
    Berikov, D.
    Mora, Y.
    Nuruyev, S.
    Pridal, P.
    Sadigov, A.
    Sadygov, Z.
    Zich, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 978
  • [29] Impact of irradiations performed at liquid helium temperatures on the operation of 0.7 μm CMOS devices and read-out circuits
    Simoen, E
    Mercha, A
    Creten, Y
    Merken, P
    Putzeys, J
    De Moor, P
    Claeys, C
    Van Hoof, C
    Mohammadzadeh, A
    Nickson, R
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2004, 536 : 369 - 375
  • [30] Read-Out Frequency Response of Solution-Processed Organic Photoconductive Devices
    Fukuda, Takeshi
    Komoriya, Mitsuo
    Mori, Ryotaro
    Honda, Zentaro
    Takahashi, Khorou
    Kamata, Norihiko
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2009, 504 : 212 - 222