Liquid argon scintillation read-out with silicon devices

被引:2
|
作者
Canci, N. [1 ,3 ]
Cattadori, C. [2 ]
D'Incecco, M. [3 ]
Lehnert, B. [4 ]
Machado, A. A. [3 ]
Riboldi, S. [5 ,6 ]
Sablone, D. [3 ]
Segreto, E. [3 ]
Vignoli, C. [3 ]
机构
[1] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
[2] INFN Milano Bicocca, Milan, Italy
[3] Ist Nazl Fis Nucl, Lab Nazl Gran Sasso, Assergi, AQ, Italy
[4] Tech Univ Dresden, Inst Kern & Teilchenphys, D-01062 Dresden, Germany
[5] Univ Milan, Dipartimento Fis, Milan, Italy
[6] INFN Milano, Milan, Italy
来源
关键词
Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; SiPMTs; G-APDs; CCDs; EBCCDs; EMCCDs etc); Noble liquid detectors (scintillation; ionization; double-phase); Large detector systems for particle and astroparticle physics; Cryogenic detectors;
D O I
10.1088/1748-0221/8/10/C10007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R&D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm(2) area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R&D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of Ge-76.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Tests of PMT signal read-out of liquid argon scintillation with a new fast waveform digitizer
    Acciarri, R.
    Canci, N.
    Cavanna, F.
    Cortopassi, A.
    D'Incecco, M.
    Mini, G.
    Pietropaolo, F.
    Romboli, A.
    Segreto, E.
    Szelc, A. M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [2] The ATLAS liquid argon calorimeter read-out system
    Bazan, A.
    Bellachia, F.
    Blondel, A.
    Colas, J.
    Citterio, M.
    Diaz Gomez, M.
    Fayard, L.
    Ionescu, G.
    Kado, M.
    Karev, A.
    Kurchaninov, L.
    Lafaye, R.
    Laforge, B.
    La Marra, D.
    Lampl, W.
    Laplace, S.
    Leger, A.
    Matricon, P.
    Nappa, J. M.
    Oberlack, H.
    Panazol, J. -L.
    Parsons, J.
    Perrot, G.
    Poggioli, L.
    Prast, J.
    Przysiezniak, H.
    Dachs, I. Riu
    Simion, S.
    Sippach, W.
    Straessner, A.
    Unal, G.
    Wilkens, H.
    Wingerter, I.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 735 - 740
  • [3] Scintillation light read-out by thin photodiodes in silicon wells
    Allier, CP
    Hollander, RW
    Sarro, PM
    van Eijk, CWE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 255 - 258
  • [4] The ATLAS liquid argon. calorimeters read-out system
    Blondel, A
    Delmastro, M
    Fayard, L
    La Marra, D
    Léger, A
    Matricon, P
    Perrott, G
    Poggioli, L
    Prast, J
    Riu, I
    Simion, S
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 293 - 296
  • [5] Development of the ATLAS Liquid Argon Calorimeter Read-out Electronics for the HL-LHC
    Gonzalez, Salvador Ventura
    26TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS, CHEP 2023, 2024, 295
  • [6] Scintillation light read-out by low-gain thin avalanche photodiodes in silicon wells
    Allier, CP
    Hollander, RW
    Sarro, PM
    de Boer, M
    van Eijk, CWE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1303 - 1306
  • [7] The read-out ASIC for silicon drift detectors
    Atkin, E.
    Ivanov, P.
    Krivchenko, A.
    Levin, V.
    Gusev, A.
    Malankin, E.
    Normanov, D.
    Rotin, A.
    Sagdiev, I.
    Shumikhin, V.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2015), PTS 1-4, 2016, 675
  • [8] LHC silicon strip detector read-out
    Nickerson, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 368 (01): : 211 - 212
  • [9] Scintillation light read-out by law-gain thin avalanche photodiodes in silicon wells.
    Allier, CP
    Hollander, RW
    Sarro, PM
    de Boer, M
    van Eijk, CWE
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 52 - 55
  • [10] ELECTRICAL READ-OUT FROM OPTICAL ALIGNMENT DEVICES
    DYSON, J
    NOBLE, PJW
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1964, 41 (05): : 311 - &