Shear bond strength of a new one-bottle dentin adhesive

被引:0
|
作者
Swift, EJ
Bayne, SC
机构
来源
AMERICAN JOURNAL OF DENTISTRY | 1997年 / 10卷 / 04期
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To test the shear bond strength of a new adhesive, 3M Single Bond, ro dentin surfaces containing different degrees of moisture. Two commercially available one-bottle adhesives (Prime & Bond, One-Step) and a conventional three-step system (Scotchbond Multi-Purpose Pins) were included fur comparison. Materials and Methods: 120 bovine teeth were embedded in acrylic and the labial surfaces were polished to 600 grit to create standardized dentin surfaces for testing. Resin composite was banded to dentin using a gelatin capsule technique. Four adhesive systems were evaluated with three different degrees of surface moisture (moist, wet, and overwet). Shear bond strengths of adhesives to dentin were determined using a universal testing machine and analyzed by ANOVA and Tukey's past hoc tests. Results: Single Band had mean shear bond strengths of 19.2, 23.2 and 20.3 MPa to moist, wet, and overwet dentin, respectively. Bond strengths of the three-component system Scotchbond Multi-Purpose Plus ranged from 23.1 to 25.3 MPa, but were not significantly higher than the values for Single Bond. Prime & Bond had bond strengths similar to those of Single Bond, but One-Step had significantly lower bond strengths (P < 0.05) in the wet and overwet conditions.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [31] Influence of different surface treatments on zirconia/resin shear bond strength using one-bottle universal adhesive
    Yang, Xin
    Liu, Yihong
    ADVANCES IN APPLIED CERAMICS, 2019, 118 (1-2) : 70 - 77
  • [32] Effects of storage conditions on shear bond strength of one-bottle adhesives.
    Sadek, FT
    Cardoso, PEC
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 206 - 206
  • [33] Shear bond strengths of acetone-based one-bottle adhesive systems.
    Lopes, GC
    Costa, G
    Rampinelli, K
    Vieira, LCC
    Baratieri, LN
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B63 - B63
  • [34] Effect of solvent type on microtensile bond strength of a total-etch one-bottle adhesive system to moist or dry dentin
    Cardoso, PC
    Lopes, GC
    Vieira, LCC
    Baratieri, LN
    OPERATIVE DENTISTRY, 2005, 30 (03) : 376 - 381
  • [35] Effect of thiol compound on the dentin bond strength when using experimental one-bottle self-etch adhesive system
    Hanabusa, Masao
    Okawa, Kazuyoshi
    Sakaeda-Naito, Nana
    Yamamoto, Takatsugu
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2024, 38 (15) : 2749 - 2761
  • [36] Dentin bond of one bottle adhesive systems
    Giannini, M
    Pimenta, LAF
    Dias, CTS
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1051 - 1051
  • [37] Effect of the hydrophilic nanofiller loading on the mechanical properties and the microtensile bond strength of an ethanol-based one-bottle dentin adhesive
    Kim, JS
    Cho, BH
    Lee, IB
    Um, CM
    Lim, BS
    Oh, MH
    Chang, CG
    Son, HH
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 284 - 291
  • [38] Microtensile bond strength of thermally stressed composite-dentin bonds mediated by one-bottle adhesives
    Xie, BS
    Dickens, SH
    Giuseppetti, AA
    AMERICAN JOURNAL OF DENTISTRY, 2002, 15 (03): : 177 - 184
  • [39] Shear bond strengths of saliva contaminated 'one-bottle' adhesives
    Taskonak, B
    Sertgöz, A
    JOURNAL OF ORAL REHABILITATION, 2002, 29 (06) : 559 - 564
  • [40] Effect of mineralization level and collagen removal on bond strength of two one-bottle adhesive systems.
    Erhardt, MCG
    Rodrigues, JA
    Pimenta, LAF
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B174 - B174