SEISMIC PERFORMANCE OF GFRP RETROFITTING CORROSION DAMAGED CONCRETE FILLED STEEL TUBE

被引:0
|
作者
Zhu, Chunyang [1 ]
Zhao, Yinghua [2 ]
Sun, Li [1 ]
Wei, Minghai [1 ]
机构
[1] Shenyang Jianzhu Univ, Shenyang 110168, Peoples R China
[2] Dalian Marinetime Univ, Dalian 116026, Peoples R China
关键词
concrete filled steel tube; corrosion damage; GFRP retrofitting; seismic performance; FRP; COLUMNS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
FRP (Fibre Reinforced Polymer) has potential in application of retrofitting for damaged concrete filled steel tube (CFST). This research studies the feasibility and effectiveness of GFRP (Glass Fibre Reinforced Polymer) seismic retrofitting for damaged CFSTs. Four corrosion damage modes created by electric accelerated corrosion were supplied on four series of CFSTs. One of two columns in each series was carried out quasi-static test directly and the other was firstly retrofitted by GFRP in proper way and then tested. The testing results showed that GFRP retrofitting can improve the seismic performance of damaged CFST. GFRP retrofitting can highly improve ductility and energy dissipation, but load bearing capacity improvement is not prominent. Circumferential corrosion crevice produces the most serious damage on seismic performance of CFST column and other material with higher stiffness are suggested to replace GFRP to prevent secondary failure in original damage zone.
引用
收藏
页码:1639 / 1644
页数:6
相关论文
共 50 条
  • [41] Seismic Performance of Hybrid Columns of Concrete-Filled Square Steel Tube with FRP-Confined Concrete Core
    Feng, Peng
    Cheng, Shi
    Yu, Tao
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (04)
  • [42] Seismic performance of concrete-encased column base for hexagonal concrete-filled steel tube: numerical study
    Han, Lin-Hai
    Hou, Chuan-Chuan
    Xu, Wu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 149 : 225 - 238
  • [43] Seismic performance of concrete-encased column connections for concrete filled thin-walled steel tube piers
    Zhou, Xuhong
    Xu, Tianxiang
    Liu, Jiepeng
    Wang, Xuanding
    Chen, Y. Frank
    Engineering Structures, 2022, 269
  • [44] Steel fiber-reinforced recycled aggregate concrete-filled GFRP tube columns: Axial compression performance
    Huang, Dongming
    Liu, Zhenzhen
    Ma, Wentao
    Lu, Yiyan
    Li, Shan
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 403
  • [45] Flexural Performance and Moment Connection of Concrete-Filled GFRP Tube-Encased Steel I-Sections
    Zakaib, Sarah
    Fam, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (05) : 604 - 613
  • [46] Assessment on seismic performance of circular concrete-filled thin-walled steel tube columns
    Wang, Xuanding
    Gao, Pan
    Liu, Jiepeng
    Zhao, Qiaorong
    Xu, Huimin
    Wei, Wei
    Wang, Xian-Tie
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (03) : 399 - 412
  • [47] Seismic Performance of Recycled Concrete Filled Circular Steel Tube Columns (vol 7, 612059, 2020)
    Xu, Dingyi
    Chen, Zongping
    Zhou, Chunheng
    FRONTIERS IN MATERIALS, 2022, 8
  • [48] Seismic performance of composite walls with concrete-filled square steel-tube boundary element
    Zhang, Jianwei
    Zheng, Wenbin
    Cao, Wanlin
    Wang, Min
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2019, 25 (12) : 2127 - 2145
  • [49] Seismic performance of prefabricated shear wall of variable sections with concrete filled steel tube and vertical patchwork
    Chen J.
    Yan W.
    Su Y.
    Chen H.
    1600, Science Press (38): : 66 - 76
  • [50] Seismic Performance Evaluation of Reinforced Concrete-Filled Steel Tube Pile/Column Bridge Bents
    Montejo, Luis A.
    Gonzalez-Roman, Lennie A.
    Kowalsky, Mervyn J.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2012, 16 (03) : 401 - 424