SEISMIC PERFORMANCE OF GFRP RETROFITTING CORROSION DAMAGED CONCRETE FILLED STEEL TUBE

被引:0
|
作者
Zhu, Chunyang [1 ]
Zhao, Yinghua [2 ]
Sun, Li [1 ]
Wei, Minghai [1 ]
机构
[1] Shenyang Jianzhu Univ, Shenyang 110168, Peoples R China
[2] Dalian Marinetime Univ, Dalian 116026, Peoples R China
关键词
concrete filled steel tube; corrosion damage; GFRP retrofitting; seismic performance; FRP; COLUMNS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
FRP (Fibre Reinforced Polymer) has potential in application of retrofitting for damaged concrete filled steel tube (CFST). This research studies the feasibility and effectiveness of GFRP (Glass Fibre Reinforced Polymer) seismic retrofitting for damaged CFSTs. Four corrosion damage modes created by electric accelerated corrosion were supplied on four series of CFSTs. One of two columns in each series was carried out quasi-static test directly and the other was firstly retrofitted by GFRP in proper way and then tested. The testing results showed that GFRP retrofitting can improve the seismic performance of damaged CFST. GFRP retrofitting can highly improve ductility and energy dissipation, but load bearing capacity improvement is not prominent. Circumferential corrosion crevice produces the most serious damage on seismic performance of CFST column and other material with higher stiffness are suggested to replace GFRP to prevent secondary failure in original damage zone.
引用
收藏
页码:1639 / 1644
页数:6
相关论文
共 50 条
  • [1] Seismic performance of seismic-damaged concrete-filled precast concrete tube columns strengthened by steel jacket and CFRP
    Zhang, Xizhi
    Wen, Longxiang
    Li, Xingqian
    Li, Shubin
    Zhang, Shaohua
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (11): : 92 - 106
  • [2] Seismic Performance of Reinforced Concrete Pier with Inside Concrete Filled Steel Tube
    Qiu, Wenliang
    Jiang, Meng
    Zhou, Le
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4194 - +
  • [3] Seismic Performance of Recycled Concrete Filled Circular Steel Tube Columns
    Xu, Dingyi
    Chen, Zongping
    Zhou, Chunheng
    FRONTIERS IN MATERIALS, 2020, 7 (07):
  • [4] Axial performance of concrete-filled GFRP tube columns jacketed by outer stainless steel tube and sandwiched concrete
    Huang, Yue
    Lu, Yiyan
    Wang, Pengpeng
    Li, Shan
    Jiao, Yifan
    ENGINEERING STRUCTURES, 2024, 314
  • [5] Seismic performance of recycled concrete-filled square steel tube columns
    Zongping Chen
    Chenggui Jing
    Jinjun Xu
    Xianggang Zhang
    Earthquake Engineering and Engineering Vibration, 2017, 16 : 119 - 130
  • [6] Seismic performance of recycled concrete-filled square steel tube columns
    Chen Zongping
    Jing Chenggui
    Xu Jinjun
    Zhang Xianggang
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2017, 16 (01) : 119 - 130
  • [7] Seismic performance of recycled aggregate concrete-filled steel tube columns
    Tang, Yun-Chao
    Li, Li-Juan
    Feng, Wen-Xian
    Liu, Feng
    Liao, Bin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 112 - 124
  • [8] Seismic performance of recycled concrete-filled square steel tube columns
    Chen Zongping
    Jing Chenggui
    Xu Jinjun
    Zhang Xianggang
    Earthquake Engineering and Engineering Vibration, 2017, 16 (01) : 119 - 130
  • [9] Seismic Performance of Concrete-Filled Steel Tube to Concrete Pile-Cap Connections
    Kappes, Lenci
    Berry, Michael
    Murray, Flynn
    Stephens, Jerry
    Barnes, Kent
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (07)
  • [10] The effect of damage location on the performance of seismically damaged concrete filled steel tube columns at fire
    Talebi, E.
    Korzen, M.
    Espinos, A.
    Hothan, S.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 835 - 842